510(k) · Cleared
ClearedBurette-in Line (150 ML)
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Tuta Healthcare Pty Limited · FPA Set, Administration, Intravascular
Cleared on Dec 18, 2002 as substantially equivalent to K984381 (Baxter Healthcare Corp, 1999) after a 51-day review. Its family tree reaches back 1 generation to 1999. 1 of the 5 devices in its family, counting itself, has a Class I recall. 3 later devices descend from it.
- Decided
- Dec 18, 2002
- Review
- 51 days
- Class
- Class II
- Product code
- FPA
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K984381 (1999). 3 later devices descend from it, 3 citing it directly. 1 of the 5 devices in this family, counting this one, has a Class I recall.
- Root · 1 generation backK984381 Buretrol Solution SetsBaxter Healthcare Corp · 1999 · Recalled (Class I)
- This deviceK023595 Burette-in Line (150 ML)Tuta Healthcare Pty Limited · 2002
- Descendant · cites it directly · 0 of its ownK121511 Maclin Power Intravascular Administration SetMaclin Power, Inc. · 2013
- Descendant · cites it directly · 0 of its ownK092905 Autostart BuretteAnalytica Pty, Ltd. · 2010
- Descendant · cites it directly · 0 of its ownK032767 Lily Volume Meteric Administration Set, Models IB-2111 and Cib-120ESLily Medical Supplies Co., Ltd. · 2004
Class I recalls in this family
- K984381 Buretrol Solution Setsdirect predicate · 1999
Most influential descendants
Showing 3 of 3 · See all- K121511Maclin Power Intravascular Administration SetMaclin Power, Inc. · 2013 · cites it directly0descendants
- K092905Autostart BuretteAnalytica Pty, Ltd. · 2010 · cites it directly0descendants
- K032767Lily Volume Meteric Administration Set, Models IB-2111 and Cib-120ESLily Medical Supplies Co., Ltd. · 2004 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K984381 | Buretrol Solution Sets | Baxter Healthcare Corp | 1999 | Class I |
| 0 (this device) | K023595 | Burette-in Line (150 ML) | Tuta Healthcare Pty Limited | 2002 | — |
| +1 | K121511 | Maclin Power Intravascular Administration Set | Maclin Power, Inc. | 2013 | — |
| +1 | K092905 | Autostart Burette | Analytica Pty, Ltd. | 2010 | — |
| +1 | K032767 | Lily Volume Meteric Administration Set, Models IB-2111 and Cib-120ES | Lily Medical Supplies Co., Ltd. | 2004 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2004 | 1 | 0 |
| 2010 | 1 | 0 |
| 2013 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FPA device
- #1 K243841 Sparta Infusion Set for Insulinscore 13.4 · 3 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K984381 | Buretrol Solution Sets Our reading of the summary gave K084381, which is not a number in FDA’s lists. Corrected to the number one digit away whose FDA name carries the summary’s words for the device, “Baxter Healthcare’s In-Line Buretrol Extension Set”. | 1999 |
What descends from it? (3)
3 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (1 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K984381Buretrol Solution SetsBaxter Healthcare Corp · 1999 · Direct predicate · ◆ on the line of descent in FIG. 14 Class I recalls
What does this lineage say?
How does its category compare?
All FPA devicesFPA Set, Administration, Intravascular: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FPA
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FPA
225in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FPA
98in 2025
Class I (17 since 2007) Class II/III not classified
Adverse event reports per year · FPA
34,506in 2025
MAUDE reports naming product code FPA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 16 | 75 | 17 | 1,499 |
| 2008 | 18 | 89 | 15 | 1,941 |
| 2009 | 10 | 166 | 166 | 2,512 |
| 2010 | 23 | 120 | 58 | 2,537 |
| 2011 | 12 | 87 | 28 | 4,407 |
| 2012 | 21 | 96 | 16 (4) | 4,930 |
| 2013 | 13 | 90 | 64 | 4,651 |
| 2014 | 22 | 89 | 24 | 4,695 |
| 2015 | 17 | 123 | 6 | 6,625 |
| 2016 | 12 | 195 | 10 | 8,470 |
| 2017 | 17 | 240 | 13 | 6,462 |
| 2018 | 4 | 177 | 4 | 6,574 |
| 2019 | 7 | 161 | 13 | 11,227 |
| 2020 | 10 | 327 | 107 | 9,563 |
| 2021 | 13 | 186 | 1 | 10,414 |
| 2022 | 14 | 213 | 9 (5) | 13,393 |
| 2023 | 14 | 340 | 12 (4) | 10,916 |
| 2024 | 7 | 244 | 13 (1) | 47,210 |
| 2025 | 11 | 225 | 98 (1) | 34,506 |
| 2026 | 5 | 266 | 10 (2) | — |
What is it indicated for?
Administration of Intravenous fluids and drugs.
The Tuta Healthcare Pty. Burette In Line (150ml) is a device used to administer fluids from a container to a patient’s vascular system Through a cannula inserted into a vein.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K023595 · printed Nov 6, 2026
Cite this page
510(k) Report. “K023595: Burette-in Line (150 ML).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K023595
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026