510(k) Report

510(k) · Cleared

Cleared

Cadence Peek Cemeent Restrictor

K023647510(k) SpecialCleared Nov 27, 200228-day reviewClass II21 CFR 878.3300

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Spinal Concepts, Inc. · JDK Prosthesis, Hip, Cement Restrictor

Cleared on Nov 27, 2002 as substantially equivalent to K022218 (Spinal Concepts, Inc., 2002) after a 28-day review. Its family tree reaches back 2 generations to 2001. 2 later devices descend from it.

Decided
Nov 27, 2002
Review
28 days
Class
Class II
Product code
JDK
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K003718 (2001). 4 ancestors in all. 2 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2001: 2 other ancestors2003: 1 descendant cleared2004: 1 descendant clearedK003718 · Titanium Cement Restrictor (TCR) · Medtronic Sofamor Danek, Inc. · 2001K022218 · Cadence Cement Restrictor · Spinal Concepts, Inc. · 2002200020052010201520202025
Other ancestors, by generationDescendants, by generation 2 generations back: 2 other ancestors 1 generation forward: 1 descendant2 generations forward: 1 descendant K022218 · Cadence Cement Restrictor · Spinal Concepts, Inc. · 2002K003718 · Titanium Cement Restrictor (TCR) · Medtronic Sofamor Danek, Inc. · 20010
  1. Root · 2 generations backK003718 Titanium Cement Restrictor (TCR)Medtronic Sofamor Danek, Inc. · 2001
  2. 1 generation backK022218 Cadence Cement RestrictorSpinal Concepts, Inc. · 2002
  3. This deviceK023647 Cadence Peek Cemeent RestrictorSpinal Concepts, Inc. · 2002
  4. Descendant · cites it directly · 1 of its ownK031318 Traxis Cement RestrictorSpinal Concepts, Inc. · 2003
  5. Descendant · 2 generations on · 0 of its ownK041583 Peek Cement Restrictor X-BoxInnovasis, Inc. · 2004

Most influential descendants

Showing 2 of 2 · See all
  • K031318Traxis Cement RestrictorSpinal Concepts, Inc. · 2003 · cites it directly1descendant
  • K041583Peek Cement Restrictor X-BoxInnovasis, Inc. · 2004 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K003718Titanium Cement Restrictor (TCR)Medtronic Sofamor Danek, Inc.2001—
−1K022218Cadence Cement RestrictorSpinal Concepts, Inc.2002—
0 (this device)K023647Cadence Peek Cemeent RestrictorSpinal Concepts, Inc.2002—
+1K031318Traxis Cement RestrictorSpinal Concepts, Inc.2003—
+2K041583Peek Cement Restrictor X-BoxInnovasis, Inc.2004—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200120

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200310
200410
FIG. 1 — Lineage of K023647, 2001–2004Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JDK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JDK device

  1. #1 K210062 Mectaplug PE IIscore 5.0 · 14 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K022218Cadence Cement RestrictorSpinal Concepts, Inc.2002—

Also cleared against K022218: 2 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K031318Traxis Cement RestrictorSpinal Concepts, Inc.20031

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 1 year and passes through 2 companies; a new generation was cleared every 1.5 years on median.
  • None of the 4 ancestors has a recall.
  • Of its descendants, K031318 (Spinal Concepts, Inc., 2003) has gone furthest, with 1 descendant of its own.
  • 2 other devices also cite its predicate K022218.

How does its category compare?

All JDK devices

JDK Prosthesis, Hip, Cement Restrictor: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JDK

1in 2021

2021: 1
2007high 1 (2021) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JDK

Too few JDK 510(k)s in any year since 2007 to give a median.

Recalls per year · JDK

5in 2011

2007: 62011: 5
2007high 6 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JDK

6in 2025

2007: 32008: 52009: 12010: 22011: 32012: 12013: 32014: 22015: 72016: 22018: 12019: 132020: 42021: 32022: 42023: 72024: 52025: 6
2007high 13 (2019) · low 0 (2017)2025

MAUDE reports naming product code JDK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—63
20080—05
20090—01
20100—02
20110—53
20120—01
20130—03
20140—02
20150—07
20160—02
20170—00
20180—01
20190—013
20200—04
20211—03
20220—04
20230—07
20240—05
20250—06
20260—0—

What is it indicated for?

The Cadence PEEK Cement Restrictor System is intended for use as a cement restrictor in orthopedic surgeries such as those involving the femoral canal and tibial plateau in hip stem and total knee replacement.

This device is not intended for any spinal indications. The safety and effectiveness of this device when implanted in the spine have not been established.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K023647: Cadence Peek Cemeent Restrictor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K023647

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026