510(k) Report

510(k) · Cleared

Cleared

System 100 Ultrafiltration Catheter

K023874510(k) TraditionalCleared Nov 20, 2003364-day reviewClass II21 CFR 876.5860

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Chf Solutions, Inc. · KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System

Cleared on Nov 20, 2003 as substantially equivalent to K013733 (Chf Solutions, Inc., 2002) and 4 other predicates after a 364-day review. Its family tree reaches back 3 generations to 1998.

Decided
Nov 20, 2003
Review
364 days
Class
Class II
Product code
KDI
Recalls
None
Predicates
5

Its longest line of descent runs back 3 generations to K981681 (1998). 7 ancestors in all, the oldest K942988 (1995). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2003: 1 other ancestor1999: 1 other ancestor1996: 1 other ancestor1995: 1 other ancestorK981681 · Prisma CFM (Continuous Fluid Management System) · Gambro Healthcare · 1998 · recalledK013733 · System 100; S-100 Ultrafiltration Console; BDT 500 Ultrafiltration Set · Chf Solutions, Inc. · 2002K023224 · Infusion Catheter Extension Set · Chf Solutions, Inc. · 200219961998200020022004
  1. Root · 3 generations backK981681 Prisma CFM (Continuous Fluid Management System)Gambro Healthcare · 1998 · Recalled
  2. 2 generations backK013733 System 100; S-100 Ultrafiltration Console; BDT 500 Ultrafiltration SetChf Solutions, Inc. · 2002
  3. 1 generation backK023224 Infusion Catheter Extension SetChf Solutions, Inc. · 2002
  4. This deviceK023874 System 100 Ultrafiltration CatheterChf Solutions, Inc. · 2003
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K981681Prisma CFM (Continuous Fluid Management System)Gambro Healthcare19981
−2K013733System 100; S-100 Ultrafiltration Console; BDT 500 Ultrafiltration SetChf Solutions, Inc.2002—
−1K023224Infusion Catheter Extension SetChf Solutions, Inc.2002—
0 (this device)K023874System 100 Ultrafiltration CatheterChf Solutions, Inc.2003—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
199610
199910
200310
FIG. 1 — Lineage of K023874, 1998–2003Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KDI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KDI device

  1. #1 K243874 FX CorAL 60 (F00012969); FX CorAL 80…score 18.2 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (5)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K013733System 100; S-100 Ultrafiltration Console; BDT 500 Ultrafiltration SetChf Solutions, Inc.2002—
*K023224Infusion Catheter Extension Set
Summary page 1
…Product code: MPB 0 CHF Solutions, System 100 0 rnedCom@, Schon XL Soft-line Devices: (KO13733, K023224, KO24124) Double Lumen Catheter /Duo- 0 Prisma (K981681)…
Chf Solutions, Inc.2002—
*K024124System 100-UF 500 Circuit with in-Line Needleless Access Port
Cleared while this submission was under review
Chf Solutions, Inc.2003—
*K981681Prisma CFM (Continuous Fluid Management System)
Summary page 1
…rnedCom@, Schon XL Soft-line Devices: (KO13733, K023224, KO24124) Double Lumen Catheter /Duo- 0 Prisma (K981681) FlowTM(K974236) I-- Device Description: The System 100 is indicate…
Gambro Healthcare19981
*K974236Medcomp Schon XL Soft-Line Double Lumen Catheter, 15CM SBF146, Medcomp Schon XL…
Summary page 1
…(KO13733, K023224, KO24124) Double Lumen Catheter /Duo- 0 Prisma (K981681) FlowTM(K974236) I-- Device Description: The System 100 is indicated for temporary (up to eight hours) ultrafilt…
Medical Components, Inc.1999—

Also cleared against K013733: 5 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 5 years and passes through 2 companies; a new generation was cleared every 1.1 years on median.
  • 3 of the 7 ancestors have a recall of any class.
  • 5 other devices also cite its predicate K013733.

How does its category compare?

All KDI devices

KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KDI

9in 2025

2007: 112008: 62009: 42010: 92011: 52012: 62013: 112014: 82015: 52016: 52017: 82018: 22019: 42020: 92021: 22022: 72023: 72024: 72025: 92026 (partial year): 6
2007high 11 (2007) · low 2 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KDI

199in 2025

2007: 91 days median2008: 148 days median2009: 236 days median2010: 186 days median2011: 85 days median2012: 153 days median2013: 247 days median2014: 164 days median2015: 69 days median2016: 230 days median2017: 188 days median2019: 263 days median2020: 266 days median2022: 259 days median2023: 157 days median2024: 235 days median2025: 199 days median2026 (partial year): 154 days median
2007high 266 (2020) · low 69 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KDI

2in 2025

2007: 42009: 32010: 12011: 42012: 12013: 22014: 32015: 52016: 42017: 12018: 12019: 62021: 22022: 172023: 8, 8 Class I2024: 4, 2 Class I2025: 22026 (partial year): 2
2007high 17 (2022) · low 0 (2008)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · KDI

2,786in 2025

2007: 9162008: 1,0422009: 5222010: 8232011: 2,2702012: 1,7652013: 2,3602014: 6,1542015: 4,1822016: 7662017: 9632018: 1,7162019: 1,5872020: 1,6332021: 1,9442022: 2,1802023: 2,6922024: 2,4412025: 2,786
2007high 6,154 (2014) · low 522 (2009)2025

MAUDE reports naming product code KDI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711914916
2008614801,042
200942363522
201091861823
201158542,270
2012615311,765
20131124722,360
2014816436,154
201556954,182
201652304766
201781881963
20182—11,716
2019426361,587
2020926601,633
20212—21,944
20227259172,180
202371578 (8)2,692
202472354 (2)2,441
2025919922,786
202661542—

What is it indicated for?

In association with central venous access: 1) The System 100 is indicated for temporary (up to eight hours) ultrafiltration treatment of patients with fluid overload. 2) The dual lumen ultrafiltration catheter [A15371 is indicated for use in attaining short-term (less than 30 days) percutaneous vascular access of the central circulatory system for ultrafiltration with the System 100. (INSERTION SITES) The dual lumen ultrafiltration catheter may be…

Read the full statement (176 words)

In association with central venous access:

1) The System 100 is indicated for temporary (up to eight hours) ultrafiltration treatment of patients with fluid overload.

2) The dual lumen ultrafiltration catheter [A15371 is indicated for use in attaining short-term (less than 30 days) percutaneous vascular access of the central circulatory system for ultrafiltration with the System 100.

(INSERTION SITES) The dual lumen ultrafiltration catheter may be inserted percutaneously and is primarily placed in the internal jugular vein of an adult patient.

Alternate insertion sites include subclavian or femoral veins as required. Use should be limited to areas within the hospital where patients with a central venous catheter are routinely managed.

3) The catheter extension [A15131 may also be used to connect commercially available CVC of the appropriate flow rate to the System 100 UF500 blood filter circuits.

4) The System 100 S-100 console [A11001 may be used when either peripheral or central venous access is employed.

5) The UF 500 circuit [A1500 and A15501 may be used when either peripheral or central venous access is employed.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K023874: System 100 Ultrafiltration Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K023874

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026