510(k) · Cleared
ClearedMBC Series
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Soring GmbH Medizintechnik · GEI Electrosurgical, Cutting & Coagulation & Accessories
Cleared on Jan 8, 2003 as substantially equivalent to K993265 (Soring GmbH Medizintechnik, 1999) after a 30-day review. Its family tree reaches back 2 generations to 1996. 26 later devices descend from it.
- Decided
- Jan 8, 2003
- Review
- 30 days
- Class
- Class II
- Product code
- GEI
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K954171 (1996). 26 later devices descend from it, 2 citing it directly.
- Root · 2 generations backK954171 Arco-MBC, Arco MCHoll Meditronics, Inc. · 1996
- 1 generation backK993265 Soring GMBH, Arco 3000, Arco 2000, Arco 1000, MBC 601, MBC 600Soring GmbH Medizintechnik · 1999
- This deviceK024059 MBC SeriesSoring GmbH Medizintechnik · 2003
- Descendant · cites it directly · 24 of its ownK052859 Aquamantys Pump Generator SystemTissuelink Medical, Inc. · 2005 · Recalled
- Descendant · 2 generations on · 7 of its ownK063639 Aquamantys SS4.0 Bipolar Sealer, Model 23-121-1Tissuelink Medical, Inc. · 2007
- Descendant · 2 generations on · 5 of its ownK111732 Aquamantys SBS 5.0 Sheated Biopolar SealerSalient Surgical Technologies, Inc. · 2011
- Descendant · 2 generations on · 4 of its ownK132974 Aquamantys 2.3 Bipolar Sealer, Evs 4.0 Epidural Vein Sealer, Mini…Medtronic Advanced Energy, LLC · 2013
- Descendant · 2 generations on · 4 of its ownK130110 Meddusa Bipolar SystemElliquence, LLC · 2013
Showing 5 of 26 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 26 · See all- K052859Aquamantys Pump Generator SystemTissuelink Medical, Inc. · 2005 · cites it directly24descendants
- K063639Aquamantys SS4.0 Bipolar Sealer, Model 23-121-1Tissuelink Medical, Inc. · 2007 · 2 generations on7descendants
- K111732Aquamantys SBS 5.0 Sheated Biopolar SealerSalient Surgical Technologies, Inc. · 2011 · 2 generations on5descendants
- K132974Aquamantys 2.3 Bipolar Sealer, Evs 4.0 Epidural Vein Sealer, Mini Evs 3.4 Epidural Vein…Medtronic Advanced Energy, LLC · 2013 · 2 generations on4descendants
- K130110Meddusa Bipolar SystemElliquence, LLC · 2013 · 2 generations on4descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K954171 | Arco-MBC, Arco MC | Holl Meditronics, Inc. | 1996 | — |
| −1 | K993265 | Soring GMBH, Arco 3000, Arco 2000, Arco 1000, MBC 601, MBC 600 | Soring GmbH Medizintechnik | 1999 | — |
| 0 (this device) | K024059 | MBC Series | Soring GmbH Medizintechnik | 2003 | — |
| +1 | K052859 | Aquamantys Pump Generator System | Tissuelink Medical, Inc. | 2005 | 1 |
| +2 | K063639 | Aquamantys SS4.0 Bipolar Sealer, Model 23-121-1 | Tissuelink Medical, Inc. | 2007 | — |
| +2 | K111732 | Aquamantys SBS 5.0 Sheated Biopolar Sealer | Salient Surgical Technologies, Inc. | 2011 | — |
| +2 | K132974 | Aquamantys 2.3 Bipolar Sealer, Evs 4.0 Epidural Vein Sealer, Mini Evs 3.4… | Medtronic Advanced Energy, LLC | 2013 | — |
| +2 | K130110 | Meddusa Bipolar System | Elliquence, LLC | 2013 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2005 | 1 | 0 |
| 2007 | 1 | 0 |
| 2008 | 1 | 0 |
| 2010 | 2 | 0 |
| 2011 | 3 | 0 |
| 2012 | 2 | 0 |
| 2013 | 3 | 0 |
| 2014 | 1 | 0 |
| 2017 | 2 | 0 |
| 2019 | 2 | 0 |
| 2020 | 1 | 0 |
| 2021 | 2 | 0 |
| 2022 | 2 | 0 |
| 2023 | 3 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GEI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new GEI device
- #1 K231790 The InMode System with the Morpheus8 Applicatorsscore 32.7 · 21 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K993265 | Soring GMBH, Arco 3000, Arco 2000, Arco 1000, MBC 601, MBC 600Summary page 1…ce: Name: Soring GmbH, ARCO 3000, ARCO 2000, ARCO 1000, and MBC Series 51O(k) Number K993265 Regulation Nurn ber 878.4400 - Device, Electrosurgical, Cutting & Coagulation &… | 1999 |
What descends from it? (26)
See all 262 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 7 years and passes through 2 companies; a new generation was cleared every 3.5 years on median.
- None of the 2 ancestors has a recall.
- Of its descendants, K052859 (Tissuelink Medical, Inc., 2005) has gone furthest, with 24 descendants of its own.
- 1 other device also cites its predicate K993265.
How does its category compare?
All GEI devicesGEI Electrosurgical, Cutting & Coagulation & Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · GEI
52in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · GEI
113in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · GEI
4in 2025
Class I (14 since 2007) Class II/III not classified
Adverse event reports per year · GEI
7,592in 2025
MAUDE reports naming product code GEI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 50 | 51 | 21 | 2,795 |
| 2008 | 61 | 71 | 19 | 2,556 |
| 2009 | 42 | 130 | 27 | 3,591 |
| 2010 | 46 | 109 | 51 | 3,377 |
| 2011 | 35 | 135 | 32 | 4,463 |
| 2012 | 39 | 133 | 30 | 5,216 |
| 2013 | 48 | 136 | 13 | 4,897 |
| 2014 | 49 | 103 | 3 | 4,908 |
| 2015 | 47 | 123 | 4 | 4,936 |
| 2016 | 64 | 108 | 3 | 5,616 |
| 2017 | 52 | 72 | 2 | 6,073 |
| 2018 | 47 | 93 | 6 | 6,545 |
| 2019 | 48 | 93 | 5 | 7,067 |
| 2020 | 59 | 105 | 1 | 6,490 |
| 2021 | 46 | 146 | 6 | 6,354 |
| 2022 | 55 | 150 | 49 | 6,103 |
| 2023 | 65 | 104 | 27 (4) | 7,176 |
| 2024 | 59 | 125 | 22 (10) | 7,897 |
| 2025 | 52 | 113 | 4 | 7,592 |
| 2026 | 43 | 183 | 8 | — |
What is it indicated for?
The devices are intended to cut and or coagulate (soft) biological tissue during surgical procedures.
Typical users of this system are trained medical professionals.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K024059 · printed Nov 6, 2026
Cite this page
510(k) Report. “K024059: MBC Series.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K024059
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026