Kinetikos Medical, Inc. · JWJ Prosthesis, Wrist, 3 Part Metal-Plastic-Metal Articulation, Semi-Constrained

Cleared on Feb 5, 2003 as substantially equivalent to K961051 (Kinetikos Medical, Inc., 1996) and 1 other predicate after a 30-day review. Its family tree reaches back 2 generations to 1996. 8 later devices descend from it.

Decided
Feb 5, 2003
Review
30 days
Class
Class II
Product code
JWJ
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K961051 (1996). 8 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2014: 2 descendants cleared2004: 1 descendant cleared2008: 1 descendant cleared2005: 1 descendant cleared2020: 2 descendants cleared2024: 1 descendant clearedK961051 · Universal Total Wrist System (Modification) · Kinetikos Medical, Inc. · 1996K020554 · Modification to Universal Total Wrist System · Kinetikos Medical, Inc. · 20021995200020052010201520202025
Descendants, by generation 1 generation forward: 2 descendants2 generations forward: 5 descendants3 generations forward: 1 descendant K020554 · Modification to Universal Total Wrist System · Kinetikos Medical, Inc. · 2002K961051 · Universal Total Wrist System (Modification) · Kinetikos Medical, Inc. · 19960
  1. Root · 2 generations backK961051 Universal Total Wrist System (Modification)Kinetikos Medical, Inc. · 1996
  2. 1 generation backK020554 Modification to Universal Total Wrist SystemKinetikos Medical, Inc. · 2002
  3. This deviceK030037 Universal Total Wrist SystemKinetikos Medical, Inc. · 2003
  4. Descendant · cites it directly · 7 of its ownK042032 Maestro Total WristBiomet, Inc. · 2004
  5. Descendant · 2 generations on · 3 of its ownK050028 Maestro Carpal HemiarthroplastyBiomet Manufacturing, Inc. · 2005
  6. Descendant · cites it directly · 2 of its ownK132250 Integra Freedom Wrist Arthroplasty SystemIntegra LifeSciences Corporation · 2014
  7. Descendant · 3 generations on · 1 of its ownK141920 Wrist Hemiarthroplasty SystemArthrosurface, Inc. · 2014
  8. Descendant · 2 generations on · 0 of its ownK233674 Freedom Wrist Arthroplasty SystemAscension Orthopedics, Inc. · 2024

Showing 5 of 8 descendants. See all descendants

Descendants cleared per year

2004: 12005: 12008: 12014: 22020: 22024: 1
2004high 2 (2014) · low 0 (2006)2026

Most influential descendants

Showing 5 of 8 · See all
  • K042032Maestro Total WristBiomet, Inc. · 2004 · cites it directly7descendants
  • K050028Maestro Carpal HemiarthroplastyBiomet Manufacturing, Inc. · 2005 · 2 generations on3descendants
  • K132250Integra Freedom Wrist Arthroplasty SystemIntegra LifeSciences Corporation · 2014 · cites it directly2descendants
  • K141920Wrist Hemiarthroplasty SystemArthrosurface, Inc. · 2014 · 3 generations on1descendant
  • K233674Freedom Wrist Arthroplasty SystemAscension Orthopedics, Inc. · 2024 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K961051Universal Total Wrist System (Modification)Kinetikos Medical, Inc.1996—
−1K020554Modification to Universal Total Wrist SystemKinetikos Medical, Inc.2002—
0 (this device)K030037Universal Total Wrist SystemKinetikos Medical, Inc.2003—
+1K042032Maestro Total WristBiomet, Inc.2004—
+2K050028Maestro Carpal HemiarthroplastyBiomet Manufacturing, Inc.2005—
+1K132250Integra Freedom Wrist Arthroplasty SystemIntegra LifeSciences Corporation2014—
+3K141920Wrist Hemiarthroplasty SystemArthrosurface, Inc.2014—
+2K233674Freedom Wrist Arthroplasty SystemAscension Orthopedics, Inc.2024—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200410
200510
200810
201420
202020
202410
FIG. 1 — Lineage of K030037, 1996–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JWJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JWJ device

  1. #1 K233574 Total Wrist Arthroplasty System (TWA)score 10.9 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K961051Universal Total Wrist System (Modification)
Summary page 1
…e device for this modification is the Kinetikos Medical Universal Total Wrist System -sizes Small, Medium and Large- originally cleared b y FDA on June 6, 1996 u n d e r K961051, and modified system version cleared May 03, 2002 under K020554. PACKAGING/LABELING/PRODUCT INFORMATION Packaging and labeling…
Kinetikos Medical, Inc.1996—
*K020554Modification to Universal Total Wrist System
Summary page 1
…l Total Wrist System -sizes Small, Medium and Large- originally cleared b y FDA on June 6, 1996 u n d e r K961051, and modified system version cleared May 03, 2002 under K020554. PACKAGING/LABELING/PRODUCT INFORMATION Packaging and labeling of the device will be the same as that of the predicate Universa…
Kinetikos Medical, Inc.2002—

Also cleared against K961051: 2 other devices →

What descends from it? (8)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K042032Maestro Total WristBiomet, Inc.20047
K132250Integra Freedom Wrist Arthroplasty SystemIntegra LifeSciences Corporation20142

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 7 years and passes through 1 company; a new generation was cleared every 5.9 years on median.
  • None of the 2 ancestors has a recall.
  • Of its descendants, K042032 (Biomet, Inc., 2004) has gone furthest, with 7 descendants of its own.
  • 2 other devices also cite its predicate K961051.

How does its category compare?

All JWJ devices

JWJ Prosthesis, Wrist, 3 Part Metal-Plastic-Metal Articulation, Semi-Constrained: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JWJ

3in 2024

2008: 12014: 12020: 22024: 3
2007high 3 (2024) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JWJ

196in 2024

2024: 196 days median
2007high 196 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JWJ

No recall names JWJ since 2007.

Adverse event reports per year · JWJ

8in 2025

2008: 12009: 42010: 52011: 42012: 72013: 92014: 112015: 72016: 482017: 372018: 312019: 1272020: 342021: 82022: 652023: 262024: 182025: 8
2007high 127 (2019) · low 0 (2007)2025

MAUDE reports naming product code JWJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—01
20090—04
20100—05
20110—04
20120—07
20130—09
20141—011
20150—07
20160—048
20170—037
20180—031
20190—0127
20202—034
20210—08
20220—065
20230—026
20243196018
20250—08
20260—0—

What is it indicated for?

Indicated for intractable pain resulting from traumatic arthritis, osteoarthritis,

rheumatoid arthritis, trauma-induced osteoarthritis of the radial/carpal joint. To

replace functionality of the joint due to deformity or elements stated above.

The Universal Total Wrist is intended for cemented use.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K030037: Universal Total Wrist System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K030037

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026