510(k) Report

510(k) · Cleared

Cleared

Diego Powered Dissector Handpiece with Starlink Image-Guided Adapter Mounting Interface

K030343510(k) TraditionalCleared May 2, 200388-day reviewClass II21 CFR 882.4560

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Gyrus Ent LLC · HAW Neurological Stereotaxic Instrument

Cleared on May 2, 2003 as substantially equivalent to K020594 (Gyrus Ent LLC, 2002) after an 88-day review. Its family tree reaches back 1 generation to 2002. 3 later devices descend from it.

Decided
May 2, 2003
Review
88 days
Class
Class II
Product code
HAW
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K020594 (2002). 3 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2008: 1 descendant cleared2013: 1 descendant cleared2022: 1 descendant clearedK020594 · Diego Powered Dissector and Drill System · Gyrus Ent LLC · 2002200020052010201520202025
Descendants, by generation 1 generation forward: 2 descendants2 generations forward: 1 descendant K020594 · Diego Powered Dissector and Drill System · Gyrus Ent LLC · 20020
  1. Root · 1 generation backK020594 Diego Powered Dissector and Drill SystemGyrus Ent LLC · 2002
  2. This deviceK030343 Diego Powered Dissector Handpiece with Starlink Image-Guided Adapter…Gyrus Ent LLC · 2003
  3. Descendant · cites it directly · 1 of its ownK123429 Olympus Energy Power System (Eps)Gyrus Acmi, Inc. · 2013 · Recalled
  4. Descendant · 2 generations on · 0 of its ownK212650 Celeris, Disposable Sinus DebriderGyrus Acmi, Inc. · 2022
  5. Descendant · cites it directly · 0 of its ownK080052 Stryker Essx with Navigation MountStryker Corp. · 2008

Most influential descendants

Showing 3 of 3 · See all
  • K123429Olympus Energy Power System (Eps)Gyrus Acmi, Inc. · 2013 · cites it directly1descendant
  • K212650Celeris, Disposable Sinus DebriderGyrus Acmi, Inc. · 2022 · 2 generations on0descendants
  • K080052Stryker Essx with Navigation MountStryker Corp. · 2008 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K020594Diego Powered Dissector and Drill SystemGyrus Ent LLC2002—
0 (this device)K030343Diego Powered Dissector Handpiece with Starlink Image-Guided Adapter Mounting…Gyrus Ent LLC2003—
+1K123429Olympus Energy Power System (Eps)Gyrus Acmi, Inc.201312
+2K212650Celeris, Disposable Sinus DebriderGyrus Acmi, Inc.2022—
+1K080052Stryker Essx with Navigation MountStryker Corp.2008—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200810
201310
202210
FIG. 1 — Lineage of K030343, 2002–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HAW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HAW device

  1. #1 K253856 Geniant Cranial (Navigated Neurosurgical…score 15.0 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K020594Diego Powered Dissector and Drill System
Summary page 1
…Device Product Code HAW Subiect Device Description The Diego Powered Dissector and Drill System Handpiece, cleared under 51O(k) K020594, has been modified to accept the BrainLAB VectorVision (K003589) and Kolibri (KO14256) Image-Guided Surgery System Instrumen…
Gyrus Ent LLC2002—

Also cleared against K020594: 4 other devices →

What descends from it? (3)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K123429Olympus Energy Power System (Eps)Gyrus Acmi, Inc.20131
K080052Stryker Essx with Navigation MountStryker Corp.20080

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K123429 (Gyrus Acmi, Inc., 2013) has gone furthest, with 1 descendant of its own.
  • 4 other devices also cite its predicate K020594.

How does its category compare?

All HAW devices

HAW Neurological Stereotaxic Instrument: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · HAW

9in 2025

2007: 152008: 122009: 82010: 62011: 42012: 82013: 32014: 52015: 102016: 92017: 72018: 62019: 102020: 52021: 92022: 72023: 142024: 72025: 92026 (partial year): 5
2007high 15 (2007) · low 3 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HAW

163in 2025

2007: 107 days median2008: 112 days median2009: 221 days median2010: 138 days median2011: 66 days median2012: 178 days median2013: 172 days median2014: 238 days median2015: 232 days median2016: 175 days median2017: 226 days median2018: 112 days median2019: 147 days median2020: 88 days median2021: 168 days median2022: 128 days median2023: 142 days median2024: 107 days median2025: 163 days median2026 (partial year): 162 days median
2007high 238 (2014) · low 66 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HAW

2in 2025

2007: 22008: 102009: 62010: 282011: 52012: 42013: 6, 1 Class I2014: 52015: 32016: 52017: 22018: 2, 2 Class I2019: 4, 1 Class I2020: 12021: 4, 2 Class I2022: 12023: 4, 1 Class I2024: 2, 2 Class I2025: 22026 (partial year): 6
2007high 28 (2010) · low 1 (2020)2026

Class I (9 since 2007) Class II/III not classified

Adverse event reports per year · HAW

3,425in 2025

2007: 492008: 532009: 962010: 2992011: 1,7252012: 9862013: 1,2902014: 1,6062015: 1,7672016: 1,8282017: 3,5052018: 4,4392019: 6,0622020: 3,4802021: 2,8272022: 1,9292023: 2,5102024: 3,7552025: 3,425
2007high 6,062 (2019) · low 49 (2007)2025

MAUDE reports naming product code HAW, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200715107249
2008121121053
20098221696
2010613828299
201146651,725
201281784986
201331726 (1)1,290
2014523851,606
20151023231,767
2016917551,828
2017722623,505
201861122 (2)4,439
2019101474 (1)6,062
202058813,480
202191684 (2)2,827
2022712811,929
2023141424 (1)2,510
202471072 (2)3,755
2025916323,425
202651626—

What is it indicated for?

The intended use of the Diego Powered Dissector and Drill System is the cutting and removal of bone and tissue in general ENT, Head & Neck, and atoneurologic procedures. Sinus applications would embody: ethrnoidectomy/sphenoethmoidectomy polypectomy septoplasty and procedures such as antrostomy endoscopic DCR frontal sinus drill-out frontal sinus trephination and irrigation septal spurs removal trans-spehn oidal procedures NasopharyngeaIAaryngeal…

Read the full statement (115 words)

The intended use of the Diego Powered Dissector and Drill System is the cutting and removal of bone and tissue in general ENT, Head & Neck, and atoneurologic procedures.

Sinus applications would embody:

ethrnoidectomy/sphenoethmoidectomy

polypectomy

septoplasty and procedures such as

antrostomy

endoscopic DCR

frontal sinus drill-out

frontal sinus trephination and irrigation

septal spurs removal

trans-spehn oidal procedures

NasopharyngeaIAaryngeal procedures would comprise:

adenoidedomy

laryngeal lesion de-bulking

laryngeal polypectomy

tracheal procedures

tonsillectomy

Otology procedures would include:

mastoidectomy

mastoidotomy.

Head & Neck procedures would encompass:

soft tissue shaving

rhinoplasty (narrowlng of the bony vault and revision of the bony pyramid)

removal of fatty (adipose) tissue (lipodebridement) in the maxillary and mandibular regions of the face

acoustic neuroma removal

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K030343: Diego Powered Dissector Handpiece with Starlink Image-Guided Adapter Mounting Interface.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K030343

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026