Alsius Corp. · NCX System, Hypothermia, Intravenous, Cooling

Cleared on Oct 23, 2003 as substantially equivalent to K012512 (Radiant Medical, 2002) and 1 other predicate after a 255-day review. Its family tree reaches back 3 generations to 1981. 15 later devices descend from it. It has been recalled 4 times.

Decided
Oct 23, 2003
Review
255 days
Class
Class II
Product code
NCX
Recalls
4
Predicates
2

Its longest line of descent runs back 3 generations to K811742 (1981). 14 ancestors in all, the oldest K811743 (1981). 15 later devices descend from it, 5 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2001: 1 other ancestor2000: 3 other ancestors1993: 1 other ancestor1991: 2 other ancestors1990: 1 other ancestor1989: 2 other ancestors1981: 1 other ancestor2005: 2 descendants cleared2007: 2 descendants cleared2008: 2 descendants cleared2004: 1 descendant cleared2010: 1 descendant cleared2014: 1 descendant cleared2016: 2 descendants cleared2015: 1 descendant cleared2021: 1 descendant cleared2023: 1 descendant cleared2022: 1 descendant clearedK811742 · Hemotherm Model 400 · Cincinnati Sub-Zero · 1981 · recalledK012512 · Setpoint Endovascular Temperature Management System · Radiant Medical · 2002K022366 · Celsius Control System · Innercool Therapies · 200319801990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 11 other ancestors 1 generation forward: 5 descendants2 generations forward: 4 descendants3 generations forward: 3 descendants4 generations forward: 1 descendant5 generations forward: 2 descendants K022366 · Celsius Control System · Innercool Therapies · 2003K012512 · Setpoint Endovascular Temperature Management System · Radiant Medical · 2002K811742 · Hemotherm Model 400 · Cincinnati Sub-Zero · 1981 · recalled0+5
  1. Root · 3 generations backK811742 Hemotherm Model 400Cincinnati Sub-Zero · 1981 · Recalled
  2. 2 generations backK012512 Setpoint Endovascular Temperature Management SystemRadiant Medical · 2002
  3. 1 generation backK022366 Celsius Control SystemInnercool Therapies · 2003
  4. This deviceK030421 Alsius Coolgard 3000 & Alsius Catheter SystemAlsius Corp. · 2003
  5. Descendant · cites it directly · 8 of its ownK052443 Icy Catheter, Model IC-3893AAlsius Corp. · 2005
  6. Descendant · 2 generations on · 7 of its ownK070161 Quattro Catheter Model IC4593Alsius Corp. · 2007
  7. Descendant · 2 generations on · 6 of its ownK101987 Cool Line Catheter, Model CL-2295A, Icy Catheter, Model IC-3893A and…Zoll Circulation · 2010
  8. Descendant · cites it directly · 5 of its ownK081936 Solex Catheter, Model SL2593Alsius Corp. · 2008
  9. Descendant · 3 generations on · 4 of its ownK150046 Start-Up Kit (SUK), Cool Line Intravascular Heat Exchange Catheter…Zoll Circulation, Inc. · 2015 · Recalled

Showing 5 of 15 descendants. See all descendants

Descendants cleared per year

2004: 12005: 22007: 22008: 22010: 12014: 12015: 12016: 22021: 12022: 12023: 1
2004high 2 (2005) · low 0 (2006)2026

Most influential descendants

Showing 5 of 15 · See all
  • K052443Icy Catheter, Model IC-3893AAlsius Corp. · 2005 · cites it directly8descendants
  • K070161Quattro Catheter Model IC4593Alsius Corp. · 2007 · 2 generations on7descendants
  • K101987Cool Line Catheter, Model CL-2295A, Icy Catheter, Model IC-3893A and Quattro Catheter…Zoll Circulation · 2010 · 2 generations on6descendants
  • K081936Solex Catheter, Model SL2593Alsius Corp. · 2008 · cites it directly5descendants
  • K150046Start-Up Kit (SUK), Cool Line Intravascular Heat Exchange Catheter, ICY Intravascular…Zoll Circulation, Inc. · 2015 · 3 generations on4descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K811742Hemotherm Model 400Cincinnati Sub-Zero19812
−2K012512Setpoint Endovascular Temperature Management SystemRadiant Medical2002—
−1K022366Celsius Control SystemInnercool Therapies2003—
0 (this device)K030421Alsius Coolgard 3000 & Alsius Catheter SystemAlsius Corp.2003—
+1K052443Icy Catheter, Model IC-3893AAlsius Corp.2005—
+2K070161Quattro Catheter Model IC4593Alsius Corp.2007—
+2K101987Cool Line Catheter, Model CL-2295A, Icy Catheter, Model IC-3893A and Quattro…Zoll Circulation2010—
+1K081936Solex Catheter, Model SL2593Alsius Corp.2008—
+3K150046Start-Up Kit (SUK), Cool Line Intravascular Heat Exchange Catheter, ICY…Zoll Circulation, Inc.201521

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198110
198920
199010
199120
199310
200030
200110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200410
200520
200720
200820
201010
201410
201510
201620
202110
202210
202310
FIG. 1 — Lineage of K030421, 1981–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NCX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NCX device

  1. #1 K213031 Solex 7 Intravascular Heat Exchange Catheter…score 10.9 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K012512Setpoint Endovascular Temperature Management SystemRadiant Medical2002—
*K022366Celsius Control SystemInnercool Therapies2003—

Also cleared against K012512: 6 other devices →

What descends from it? (15)

See all 15

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K052443Icy Catheter, Model IC-3893AAlsius Corp.20058
K081936Solex Catheter, Model SL2593Alsius Corp.20085
K033623Celsius Control SystemInnercool Therapies, Inc.20042
K071358Reprieve Endovascular Temperature Therapy SystemRadiant Medical20070
K051912Cool Line Catheter Kit, Models CL-2085B, CL-2295A; Icy Catheter Kit, Model IC-3585A…Alsius Corp.20050

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Nov 9, 2005Not classifiedZ-0369-06OtherAlsius has found that fluid spills or ingress may result in an alarm condition. The potential health risk involved in this state can be the discontinuance of therapy.
Jul 25, 2005Not classifiedZ-1397-05OtherFirm wants users to be aware not to leave the units in standby mode for more than an hour in rooms in excess of 75 F due to risk of an alarm mode being generated due to overheating.
Nov 10, 2004Not classifiedZ-0258-05OtherProduct alarms that there may be a power supply interruption.
Jun 21, 2004Not classifiedZ-1159-04OtherHigher than expected rate of pump alarms occur under specific conditions.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 22 years and passes through 4 companies; a new generation was cleared every 9 months on median.
  • 6 of the 14 ancestors have a recall of any class.
  • Of its descendants, K052443 (Alsius Corp., 2005) has gone furthest, with 8 descendants of its own.
  • 6 other devices also cite its predicate K012512.

How does its category compare?

All NCX devices

NCX System, Hypothermia, Intravenous, Cooling: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · NCX

1in 2023

2007: 62008: 32010: 12014: 12015: 12016: 32021: 12022: 12023: 1
2007high 6 (2007) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NCX

204in 2016

2007: 28 days median2008: 129 days median2016: 204 days median
2007high 204 (2016) · low 28 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NCX

28in 2021

2007: 22014: 12021: 28
2007high 28 (2021) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · NCX

273in 2025

2007: 42008: 82009: 42010: 92011: 72012: 142013: 312014: 412015: 322016: 3112017: 4502018: 5092019: 4362020: 4152021: 4612022: 5112023: 3732024: 3432025: 273
2007high 511 (2022) · low 4 (2007)2025

MAUDE reports naming product code NCX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200762824
2008312908
20090—04
20101—09
20110—07
20120—014
20130—031
20141—141
20151—032
201632040311
20170—0450
20180—0509
20190—0436
20200—0415
20211—28461
20221—0511
20231—0373
20240—0343
20250—0273
20260—0—

What is it indicated for?

The COOLGARD™ 3000/Alsius Catheter Thermal Regulation System, using either the Icy™ or Fortius™ model catheter, is indicated for use: in cardiac surgery patients to achieve and or maintain normothermia during surgery and recovery/intensive care, and, to induce, maintain and reverse mild hypothermia in neurosurgery patients in surgery and recovery/intensive care.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K030421: Alsius Coolgard 3000 & Alsius Catheter System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K030421

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026