510(k) Report

510(k) · Cleared

Cleared

Rapid Imf

K030605510(k) TraditionalCleared Jun 27, 2003122-day reviewClass II21 CFR 872.4600

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Zygomatics, Ltd. · DYX Lock, Wire, And Ligature, Intraoral

Cleared on Jun 27, 2003 after a 122-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 1 later device descends from it.

Decided
Jun 27, 2003
Review
122 days
Class
Class II
Product code
DYX
Recalls
None
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2017: 1 descendant cleared200020052010201520202025
  1. This deviceK030605 Rapid ImfZygomatics, Ltd. · 2003
  2. Descendant · cites it directly · 0 of its ownK162046 MINNE TIES MMF Suture SystemSummit Medical, Inc. · 2017

Most influential descendants

Showing 1 of 1 · See all
  • K162046MINNE TIES MMF Suture SystemSummit Medical, Inc. · 2017 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K030605Rapid ImfZygomatics, Ltd.2003—
+1K162046MINNE TIES MMF Suture SystemSummit Medical, Inc.2017—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201710
FIG. 1 — Lineage of K030605, 2003–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DYX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K162046MINNE TIES MMF Suture SystemSummit Medical, Inc.20170

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K162046 (Summit Medical, Inc., 2017) has gone furthest, with 0 descendants of its own.

How does its category compare?

All DYX devices

DYX Lock, Wire, And Ligature, Intraoral: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DYX

1in 2017

2017: 1
2007high 1 (2017) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DYX

Too few DYX 510(k)s in any year since 2007 to give a median.

Recalls per year · DYX

No recall names DYX since 2007.

Adverse event reports per year · DYX

1in 2016

2012: 22016: 1
2007high 2 (2012) · low 0 (2007)2025

MAUDE reports naming product code DYX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—02
20130—00
20140—00
20150—00
20160—01
20171—00
20180—00
20190—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The Rapid IMF is an adjustable flexible plastic band that wraps around a tooth to

create an anchorage point for maxillo-mandibular fixation and immobilisation (similar

to an orthodontic band). Rapid IMF is suitable for:

= Pre-operative fixation

= Per-operative fixation

Short-temi (up to 3 weeks) fixation for minimally displaced fractures

Splintage post jaw dislocation

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K030605: Rapid Imf.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K030605

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026