510(k) Report

510(k) · Cleared

Recalled · 2007

Lifesyne Systems

K030795510(k) TraditionalCleared Aug 5, 2003146-day reviewClass II21 CFR 870.2910Recalls 3

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Gmp/Companies, Inc. · DRG Transmitters And Receivers, Physiological Signal, Radiofrequency

Cleared on Aug 5, 2003 as substantially equivalent to K974149 (Mortara Instrument, Inc., 1998) after a 146-day review. Its family tree reaches back 2 generations to 1989. 109 later devices descend from it. It has been recalled 3 times.

Decided
Aug 5, 2003
Review
146 days
Class
Class II
Product code
DRG
Recalls
3
Predicates
1

Its longest line of descent runs back 2 generations to K891104 (1989). 3 ancestors in all. 109 later devices descend from it, 4 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1993: 1 other ancestor2009: 1 descendant cleared2006: 1 descendant cleared2012: 3 descendants cleared2010: 1 descendant cleared2008: 1 descendant cleared2015: 4 descendants cleared2011: 2 descendants cleared2014: 1 descendant cleared2016: 3 descendants cleared2017: 5 descendants cleared2013: 1 descendant cleared2020: 9 descendants cleared2019: 9 descendants cleared2018: 6 descendants cleared2022: 8 descendants cleared2025: 16 descendants cleared2021: 5 descendants cleared2024: 12 descendants cleared2023: 13 descendants cleared2026: 8 descendants clearedK891104 · CD Telemetry Systems · Marquette Electronics, Inc. · 1989K974149 · Ambulatory X-12 Telemetry Module · Mortara Instrument, Inc. · 1998 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor 1 generation forward: 4 descendants2 generations forward: 6 descendants3 generations forward: 12 descendants4 generations forward: 17 descendants5 generations forward: 24 descendants6 generations forward: 16 descendants7 generations forward: 17 descendants8 generations forward: 4 descendants9 generations forward: 6 descendants10 generations forward: 3 descendants K974149 · Ambulatory X-12 Telemetry Module · Mortara Instrument, Inc. · 1998 · recalledK891104 · CD Telemetry Systems · Marquette Electronics, Inc. · 19890+5+10
  1. Root · 2 generations backK891104 CD Telemetry SystemsMarquette Electronics, Inc. · 1989
  2. 1 generation backK974149 Ambulatory X-12 Telemetry ModuleMortara Instrument, Inc. · 1998 · Recalled
  3. This deviceK030795 Lifesyne SystemsGmp/Companies, Inc. · 2003
  4. Descendant · cites it directly · 99 of its ownK061993 Equivital, Model EQ-01Hidalgo Limited · 2006
  5. Descendant · cites it directly · 71 of its ownK113054 EquivitalHidalgo Limited · 2012
  6. Descendant · 2 generations on · 70 of its ownK141167 Vitalconnect Platform (Consisting of Vitalconnect Sensor, Relay…Vitalconnect, Inc. · 2014
  7. Descendant · 3 generations on · 43 of its ownK152139 Vital Connect Platform, HealthPatch MD, VitalPatchVitalconnect, Inc. · 2015
  8. Descendant · 2 generations on · 22 of its ownK081140 VisensiaObs Medical · 2008

Showing 5 of 109 descendants. See all descendants

Descendants cleared per year

2006: 12008: 12009: 12010: 12011: 22012: 32013: 12014: 12015: 42016: 32017: 52018: 62019: 92020: 92021: 52022: 82023: 132024: 122025: 162026: 8
2006high 16 (2025) · low 0 (2007)2026

Most influential descendants

Showing 5 of 109 · See all
  • K061993Equivital, Model EQ-01Hidalgo Limited · 2006 · cites it directly99descendants
  • K113054EquivitalHidalgo Limited · 2012 · cites it directly71descendants
  • K141167Vitalconnect Platform (Consisting of Vitalconnect Sensor, Relay Software Library and…Vitalconnect, Inc. · 2014 · 2 generations on70descendants
  • K152139Vital Connect Platform, HealthPatch MD, VitalPatchVitalconnect, Inc. · 2015 · 3 generations on43descendants
  • K081140VisensiaObs Medical · 2008 · 2 generations on22descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K891104CD Telemetry SystemsMarquette Electronics, Inc.1989—
−1K974149Ambulatory X-12 Telemetry ModuleMortara Instrument, Inc.19981
0 (this device)K030795Lifesyne SystemsGmp/Companies, Inc.2003—
+1K061993Equivital, Model EQ-01Hidalgo Limited2006—
+1K113054EquivitalHidalgo Limited2012—
+2K141167Vitalconnect Platform (Consisting of Vitalconnect Sensor, Relay Software…Vitalconnect, Inc.2014—
+3K152139Vital Connect Platform, HealthPatch MD, VitalPatchVitalconnect, Inc.2015—
+2K081140VisensiaObs Medical2008—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200610
200810
200910
201010
201120
201230
201310
201410
201540
201630
201750
201860
201990
202090
202150
202280
2023130
2024120
2025160
202680
FIG. 1 — Lineage of K030795, 1989–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DRG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DRG device

  1. #1 K223711 ANNE Onescore 20.8 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K974149Ambulatory X-12 Telemetry Module
Summary page 1
…ICE The GMPl Wireless Medicine LifeSyncTMSystem is substantially equivalent to the Mortara Ambulatory X-12 Telemetry Module that was cleared by FDA under K974149 on January 8, 1998. B. DEVICE DESCRIPTION The GMPlWireless Medicine LifeSyncTMSystem is comprised of 4 primary comp…
Mortara Instrument, Inc.19981

Also cleared against K974149: 6 other devices →

What descends from it? (109)

See all 109

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K061993Equivital, Model EQ-01Hidalgo Limited200699
K113054EquivitalHidalgo Limited201271
K090610Hospira Vital Signs Wireless Monitoring SystemHospira, Inc.20099
K100040BioharnessZephyr Technology Corporation20103

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Dec 13, 2007Not classifiedZ-1659-2008Nonconforming Material/ComponentLifeSync Wireless ECG System - Intermittent failure when using LS-202 and LS-232 LeadWear in conjunction with LS-41245 and LS-41285 Adaptors. The out of box failure manifests as a V-Lead failure, leading to a possible delay in treatment…
Dec 13, 2007Not classifiedZ-1660-2008Nonconforming Material/ComponentLifeSync Wireless ECG System - Intermittent failure when using LS-202 and LS-232 LeadWear in conjunction with LS-41245 and LS-41285 Adaptors. The out of box failure manifests as a V-Lead failure, intended for use as a radiofrequency…
Jan 10, 2007Not classifiedZ-0546-2007OtherWhen the V-lead is separated from the rest of the lead set, the laminate may tear, exposing the dielectric layer causing a break in the silver ink. If the product is used during a defibrillation after such a de-lamination, it could burn…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 3 companies; a new generation was cleared every 8.7 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • Of its descendants, K061993 (Hidalgo Limited, 2006) has gone furthest, with 99 descendants of its own.
  • 6 other devices also cite its predicate K974149.

How does its category compare?

All DRG devices

DRG Transmitters And Receivers, Physiological Signal, Radiofrequency: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DRG

3in 2025

2007: 62008: 52009: 132010: 102011: 92012: 122013: 132014: 102015: 22016: 22017: 72018: 62019: 52020: 62021: 22022: 62023: 42024: 32025: 32026 (partial year): 2
2007high 13 (2009) · low 2 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DRG

127in 2025

2007: 63 days median2008: 74 days median2009: 94 days median2010: 68 days median2011: 104 days median2012: 103 days median2013: 146 days median2014: 177 days median2017: 98 days median2018: 220 days median2019: 122 days median2020: 159 days median2022: 287 days median2023: 212 days median2024: 125 days median2025: 127 days median
2007high 287 (2022) · low 63 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DRG

3in 2007

2007: 32026 (partial year): 1
2007high 3 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DRG

52in 2025

2007: 142008: 92009: 52010: 132011: 122012: 92013: 132014: 972015: 1312016: 1822017: 4842018: 1662019: 702020: 822021: 1072022: 432023: 192024: 262025: 52
2007high 484 (2017) · low 5 (2009)2025

MAUDE reports naming product code DRG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007663314
200857409
2009139405
20101068013
20119104012
20121210309
201313146013
201410177097
20152—0131
20162—0182
20177980484
201862200166
20195122070
20206159082
20212—0107
20226287043
20234212019
20243125026
20253127052
20262—1—

What is it indicated for?

The GMPlWireless Medicine LifeSyncTMSystem is indicated for use when ECG monitoring is needed and a wireless cable-free connection is desired between the patient and the ECG Monitor. The LifeSyncTMSystem will also transmit the patient respiration waveform for those ECG systems that include a respiration function.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K030795: Lifesyne Systems.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K030795

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026