Bayer Advia 1650 Special Chemistry Calibrator

K030804510(k) AbbreviatedCleared Apr 10, 200328-day reviewClass II21 CFR 862.1150

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bayer Healthcare, LLC · JIX Calibrator, Multi-Analyte Mixture

Cleared on Apr 10, 2003 as substantially equivalent to K023840 (Bayer Diagnostics Corp., 2003) after a 28-day review. Its family tree reaches back 1 generation to 2003. 1 later device descends from it.

Decided
Apr 10, 2003
Review
28 days
Class
Class II
Product code
JIX
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K023840 (2003). 1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2003: 1 descendant clearedK023840 · Acid Phosphatase Assay for the Advia 1650 · Bayer Diagnostics Corp. · 2003200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant K023840 · Acid Phosphatase Assay for the Advia 1650 · Bayer Diagnostics Corp. · 20030
  1. Root · 1 generation backK023840 Acid Phosphatase Assay for the Advia 1650Bayer Diagnostics Corp. · 2003
  2. This deviceK030804 Bayer Advia 1650 Special Chemistry CalibratorBayer Healthcare, LLC · 2003
  3. Descendant · cites it directly · 0 of its ownK033380 Bayer Special Chemistry CalibratorsBayer Diagnostics Corp. · 2003

Most influential descendants

Showing 1 of 1 · See all
  • K033380Bayer Special Chemistry CalibratorsBayer Diagnostics Corp. · 2003 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K023840Acid Phosphatase Assay for the Advia 1650Bayer Diagnostics Corp.2003—
0 (this device)K030804Bayer Advia 1650 Special Chemistry CalibratorBayer Healthcare, LLC2003—
+1K033380Bayer Special Chemistry CalibratorsBayer Diagnostics Corp.2003—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200310
FIG. 1 — Lineage of K030804, 2003–2003Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JIX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K023840Acid Phosphatase Assay for the Advia 1650Bayer Diagnostics Corp.2003—

Also cleared against K023840: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K033380Bayer Special Chemistry CalibratorsBayer Diagnostics Corp.20030

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K033380 (Bayer Diagnostics Corp., 2003) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K023840.

How does its category compare?

All JIX devices

JIX Calibrator, Multi-Analyte Mixture: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JIX

1in 2016

2007: 62008: 52009: 42010: 52011: 72012: 22013: 42014: 12015: 32016: 1
2007high 7 (2011) · low 0 (2017)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JIX

29in 2015

2007: 53 days median2008: 69 days median2009: 121 days median2010: 100 days median2011: 77 days median2013: 50 days median2015: 29 days median
2007high 121 (2009) · low 29 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JIX

7in 2023

2007: 22008: 32009: 22010: 12011: 22012: 12014: 12016: 12017: 12018: 12019: 12020: 22023: 72026 (partial year): 1
2007high 7 (2023) · low 0 (2013)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JIX

18in 2025

2007: 1402008: 1732009: 392011: 92012: 32013: 242014: 352015: 42016: 62017: 172018: 162019: 122020: 222021: 92022: 112023: 132024: 152025: 18
2007high 173 (2008) · low 0 (2010)2025

MAUDE reports naming product code JIX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20076532140
20085693173
20094121239
2010510010
201177729
20122—13
2013450024
20141—135
201532904
20161—16
20170—117
20180—116
20190—112
20200—222
20210—09
20220—011
20230—713
20240—015
20250—018
20260—1—

What is it indicated for?

For in vitro diagnostic use in the calibration of the ADVIA 1650 Chemistry system for certain chemistry methods.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K030804: Bayer Advia 1650 Special Chemistry Calibrator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K030804

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026