510(k) Report

510(k) · Cleared

Cleared

MSD Cable Reduction System

K030816510(k) TraditionalCleared Jun 6, 200384-day reviewClass II21 CFR 888.3050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Medtronic Sofamor Danek · KWP Appliance, Fixation, Spinal Interlaminal

Cleared on Jun 6, 2003 after an 84-day review. The FDA summary names its predicate without a number. 1 later device descends from it.

Decided
Jun 6, 2003
Review
84 days
Class
Class II
Product code
KWP
Recalls
None
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2007: 1 descendant cleared200020052010201520202025
  1. This deviceK030816 MSD Cable Reduction SystemMedtronic Sofamor Danek · 2003
  2. Descendant · cites it directly · 0 of its ownK071271 Biomet Cable SystemBiomet Manufacturing, Inc. · 2007

Most influential descendants

Showing 1 of 1 · See all
  • K071271Biomet Cable SystemBiomet Manufacturing, Inc. · 2007 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K030816MSD Cable Reduction SystemMedtronic Sofamor Danek2003—
+1K071271Biomet Cable SystemBiomet Manufacturing, Inc.2007—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200710
FIG. 1 — Lineage of K030816, 2003–2007Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KWP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—ATLAS CABLE System
Named without a submission number
—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K071271Biomet Cable SystemBiomet Manufacturing, Inc.20070

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K071271 (Biomet Manufacturing, Inc., 2007) has gone furthest, with 0 descendants of its own.

How does its category compare?

All KWP devices

KWP Appliance, Fixation, Spinal Interlaminal: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KWP

9in 2015

2007: 142008: 132009: 122010: 142011: 122012: 182013: 122014: 132015: 9
2007high 18 (2012) · low 0 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KWP

113in 2015

2007: 96 days median2008: 50 days median2009: 89 days median2010: 186 days median2011: 67 days median2012: 112 days median2013: 99 days median2014: 138 days median2015: 113 days median
2007high 186 (2010) · low 50 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KWP

2in 2022

2007: 22008: 12009: 232010: 22011: 62012: 12013: 32015: 12016: 32018: 12019: 22022: 2
2007high 23 (2009) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KWP

494in 2025

2007: 2102008: 5942009: 6822010: 4742011: 7922012: 9182013: 1,0902014: 1,0222015: 1,3482016: 1,3792017: 8642018: 6572019: 5182020: 7962021: 5252022: 3352023: 3322024: 4362025: 494
2007high 1,379 (2016) · low 210 (2007)2025

MAUDE reports naming product code KWP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200714962210
200813501594
2009128923682
2010141862474
201112676792
2012181121918
2013129931,090
20141313801,022
2015911311,348
20160—31,379
20170—0864
20180—1657
20190—2518
20200—0796
20210—0525
20220—2335
20230—0332
20240—0436
20250—0494
20260—0—

What is it indicated for?

The MSD CABLE REDUCTION SYSTEM screws and hooks are only intended for use in the thoracic and lumbar spine. The system provides an alternative to sublaminar and intraspinous process wiring for trauma applications. Another application is the use of the MSD CABLE REDUCTION SYSTEM for instrumentation involved in the correction of scoliotic, kyphotic, and lordotic deformities. The system may also be used with other spinal implants such as the MSD Unit Rod, the ATLASTMCABLE System or the Luque Rod, or wherever “wiring” may help secure the attachment of other implants.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K030816: MSD Cable Reduction System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K030816

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026