510(k) Report

510(k) · Cleared

Cleared

Modification to Hermes O.R. Control Center

K031720510(k) SpecialCleared Jul 11, 200338-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Computer Motion, Inc. · GCJ Laparoscope, General & Plastic Surgery

Cleared on Jul 11, 2003 as substantially equivalent to K973700 (Computer Motion, Inc., 1998) and 1 other predicate after a 38-day review. Its family tree reaches back 6 generations to 1993.

Decided
Jul 11, 2003
Review
38 days
Class
Class II
Product code
GCJ
Recalls
None
Predicates
2

Its longest line of descent runs back 6 generations to K931783 (1993). 8 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 6 generations backK931783 Aesop (Automated Endoscopic System for Optimal PosComputer Motion, Inc. · 1993
  2. 5 generations backK960655 Aesop System and AccessoriesComputer Motion, Inc. · 1996
  3. 4 generations backK973700 Hermes Operating Room Control CenterComputer Motion, Inc. · 1998
  4. 3 generations backK023095 Hermes Operating Room Control CenterComputer Motion, Inc. · 2002
  5. 2 generations backK024294 Modification to Hermes Operating Room Control CenterComputer Motion, Inc. · 2003
  6. 1 generation backK030240 Modification to Hermes Operating Room Control CenterComputer Motion, Inc. · 2003
  7. This deviceK031720 Modification to Hermes O.R. Control CenterComputer Motion, Inc. · 2003
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K931783Aesop (Automated Endoscopic System for Optimal PosComputer Motion, Inc.1993—
−5K960655Aesop System and AccessoriesComputer Motion, Inc.1996—
−4K973700Hermes Operating Room Control CenterComputer Motion, Inc.1998—
−3K023095Hermes Operating Room Control CenterComputer Motion, Inc.2002—
−2K024294Modification to Hermes Operating Room Control CenterComputer Motion, Inc.2003—
−1K030240Modification to Hermes Operating Room Control CenterComputer Motion, Inc.2003—
0 (this device)K031720Modification to Hermes O.R. Control CenterComputer Motion, Inc.2003—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610
200010
FIG. 1 — Lineage of K031720, 1993–2003Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GCJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GCJ device

  1. #1 K214046 780 nm 1688 4K Camera System, 780 nm L11 LED…score 21.4 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K973700Hermes Operating Room Control Center
Summary page 1
…c Surgeiy Regulation Number: 876.1500 Regulation Class: Class 11. This device is substantially equivalent to the HERMES O.R. Control Center, K973700, and the more recent 510(k) for HERMES control of the S&N Dyonics@ Power Shaver, K030240. The HERMES O.R. Control…
Computer Motion, Inc.1998—
*K030240Modification to Hermes Operating Room Control Center
Summary page 1
…ice is substantially equivalent to the HERMES O.R. Control Center, K973700, and the more recent 510(k) for HERMES control of the S&N Dyonics@ Power Shaver, K030240. The HERMES O.R. Control Center is a computer-driven system whose basic function is to offer the surgeon the addit…
Computer Motion, Inc.2003—

Also cleared against K973700: 8 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 10 years and passes through 1 company; a new generation was cleared every 1.8 years on median.
  • None of the 8 ancestors has a recall.
  • 8 other devices also cite its predicate K973700.

How does its category compare?

All GCJ devices

GCJ Laparoscope, General & Plastic Surgery: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GCJ

21in 2025

2007: 182008: 192009: 212010: 242011: 152012: 172013: 152014: 192015: 262016: 272017: 202018: 212019: 152020: 282021: 182022: 202023: 312024: 292025: 212026 (partial year): 26
2007high 31 (2023) · low 15 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GCJ

108in 2025

2007: 42 days median2008: 73 days median2009: 85 days median2010: 122 days median2011: 113 days median2012: 88 days median2013: 93 days median2014: 90 days median2015: 76 days median2016: 99 days median2017: 77 days median2018: 88 days median2019: 60 days median2020: 61 days median2021: 116 days median2022: 103 days median2023: 109 days median2024: 90 days median2025: 108 days median2026 (partial year): 122 days median
2007high 122 (2010) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GCJ

5in 2025

2007: 122008: 162009: 62010: 302011: 92012: 12013: 7, 1 Class I2014: 22016: 52017: 12018: 12022: 12023: 12025: 52026 (partial year): 1
2007high 30 (2010) · low 0 (2015)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · GCJ

5,860in 2025

2007: 1,6392008: 1,3192009: 1,9952010: 2,6572011: 2,1332012: 1,5262013: 1,5652014: 1,7142015: 1,7102016: 2,0802017: 3,4682018: 2,5622019: 2,5782020: 2,6182021: 3,4312022: 3,9452023: 6,0022024: 6,0472025: 5,860
2007high 6,047 (2024) · low 1,319 (2008)2025

MAUDE reports naming product code GCJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071842121,639
20081973161,319
2009218561,995
201024122302,657
20111511392,133
2012178811,526
201315937 (1)1,565
2014199021,714
2015267601,710
2016279952,080
2017207713,468
2018218812,562
2019156002,578
2020286102,618
20211811603,431
20222010313,945
20233110916,002
2024299006,047
20252110855,860
2026261221—

What is it indicated for?

The [email protected]. Control Center and Port Expander is indicated for use with Stryker Endoscopy 882 Camera, Stryker Quantum 5000 Light Source, Stryker SE5 Shaver, WOM 201 Insufflator System, WOM 2.0L Arthroscopy Pump, Stryker Total Performance System, Berchtold Surgical Li hts, Steris Amsco Table Model SP3085, Steris Amsco Table Model SP3085, AESOP HR (HERMES-ReadyTM),Valleylab Force FXTMElectro-surgical Unit, Smith & Nephew Dyonics" Access 15 Arthroscopic…

Read the full statement (209 words)

The [email protected]. Control Center and Port Expander is indicated for use with Stryker Endoscopy 882 Camera, Stryker Quantum 5000 Light Source, Stryker SE5 Shaver, WOM 201 Insufflator System, WOM 2.0L Arthroscopy Pump, Stryker Total Performance System, Berchtold Surgical Li hts, Steris Amsco Table Model SP3085, Steris Amsco Table Model SP3085, AESOP HR (HERMES-ReadyTM),Valleylab Force FXTMElectro-surgical Unit, Smith & Nephew Dyonics" Access 15 Arthroscopic Fluid Irrigation System, Smith & Nephew Dyonics@Vision 635 Digital Image Management System, Skytron Stellar Series O.R. Lights, S&N Dyonics" Power Shaver (K030240) and the Smith & Nephew InteliJET Arthroscopic Fluid Management System. It can be used in general laparoscopy, nasopharyngoscopy, ear endoscopy, and sinuscopy where a laparoscope/endoscope is indicated for use. A few examples of the more common endoscopic surgeries are laparoscopic cholecystectomy, laparoscopic hernia repair, laparoscopic appendectomy, laparoscopic pelvic lymph node dissection, laparoscopically assisted hysterectomy, laparoscopic & thoracoscopic anterior spinal fusion, decompression fixation, wedge resection, lung biopsy, pleural biopsy, dorsal sympathectomy, pleurodesis, internal mammary artery dissection for coronary artery bypass, coronary artery bypass grafting where endoscopic visualization in indicated and examination of the evacuated cardiac chamber during performance of valve replacement. The users of the HERMES O.R. Control Center are general surgeons, gynecologists, cardiac surgeons, thoracic surgeons, plastic surgeons, orthopedic surgeons, ENT surgeons and urologists.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K031720: Modification to Hermes O.R. Control Center.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K031720

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026