510(k) · Cleared
ClearedStryker Plating System Periarticular Plates
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Howmedica Osteonics Corp. · LXT Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component, Metal Composite
Cleared on Jul 25, 2003 after a 30-day review. The FDA summary names its predicate without a number.
- Decided
- Jul 25, 2003
- Review
- 30 days
- Class
- Class II
- Product code
- LXT
- Recalls
- None
- Predicates
- 0
The FDA summary names its predicate without a number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LXT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LXT device
- #1 K230067 Para-Fix External Fixation Systemscore 6.4 · 2 generations · no Class I recall
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | SPS Small Fragment Set Named without a submission number | |
| * | — | SPS Basic Fragment Set Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All LXT devicesLXT Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component, Metal Composite: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · LXT
1in 2023
2026 to Oct 25, outlined.
Median 510(k) review, days · LXT
Too few LXT 510(k)s in any year since 2007 to give a median.
Recalls per year · LXT
2in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LXT
7in 2025
MAUDE reports naming product code LXT, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 1 | 26 |
| 2008 | 1 | — | 0 | 58 |
| 2009 | 1 | — | 7 | 41 |
| 2010 | 0 | — | 0 | 33 |
| 2011 | 1 | — | 0 | 85 |
| 2012 | 0 | — | 0 | 42 |
| 2013 | 2 | — | 0 | 39 |
| 2014 | 0 | — | 0 | 36 |
| 2015 | 0 | — | 0 | 35 |
| 2016 | 0 | — | 0 | 38 |
| 2017 | 0 | — | 0 | 66 |
| 2018 | 0 | — | 2 | 73 |
| 2019 | 0 | — | 0 | 40 |
| 2020 | 0 | — | 0 | 32 |
| 2021 | 0 | — | 0 | 24 |
| 2022 | 0 | — | 0 | 21 |
| 2023 | 1 | — | 0 | 18 |
| 2024 | 0 | — | 0 | 27 |
| 2025 | 0 | — | 0 | 7 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The 3.5mm and 4.5mm Periarticular Plate components are intended for use in long bone fracture fixation.
The 3.5mm and 4.5mm proximal tibial Periarticular Plates are indicated for fixation of long bone fractures, including, but not limited to, fractures of the tibia. The 4.5mm distal femur Periarticular Plates are indicated for fixation of long bone fractures, including, but not limited to, fractures of the femur.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K031959 · printed Nov 5, 2026
Cite this page
510(k) Report. “K031959: Stryker Plating System Periarticular Plates.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K031959
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026