510(k) Report

510(k) · Cleared

Cleared

Vitros Immunodiagnostic Products Progestrone Reagent Pack and Calibrators

K032296510(k) SpecialCleared Aug 13, 200319-day reviewClass II21 CFR 862.1150

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ortho-Clinical Diagnostics, Inc. · JIS Calibrator, Primary

Cleared on Aug 13, 2003 as substantially equivalent to K022901 (Ortho-Clinical Diagnostics, 2002) after a 19-day review. Its family tree reaches back 2 generations to 1997.

Decided
Aug 13, 2003
Review
19 days
Class
Class II
Product code
JIS
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K972133 (1997). No later device cites it as a predicate yet.

  1. Root · 2 generations backK972133 Vitros Immunodiagnostics Products Progesterone Reagent Pack…Johnson & Johnson Clinical Diagnostics, Inc. · 1997
  2. 1 generation backK022901 Vitros Immunodiagnostic Products Progesterone Reagent Pack and…Ortho-Clinical Diagnostics · 2002
  3. This deviceK032296 Vitros Immunodiagnostic Products Progestrone Reagent Pack and…Ortho-Clinical Diagnostics, Inc. · 2003
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K972133Vitros Immunodiagnostics Products Progesterone Reagent Pack (Gem.1070)…Johnson & Johnson Clinical Diagnostics, Inc.1997—
−1K022901Vitros Immunodiagnostic Products Progesterone Reagent Pack and CalibratorsOrtho-Clinical Diagnostics2002—
0 (this device)K032296Vitros Immunodiagnostic Products Progestrone Reagent Pack and CalibratorsOrtho-Clinical Diagnostics, Inc.2003—
FIG. 1 — Lineage of K032296, 1997–2003Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JIS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K022901Vitros Immunodiagnostic Products Progesterone Reagent Pack and Calibrators
Summary page 3
…ied) are device substantially equivalent to VITROS Immunodiagnostic Products Progesterone Reagent Pack and Calibrators cleared by the FDA (K022901) for in vitro diagnostic use. Table 1 lists the characteristics of the modified VITROS…
Ortho-Clinical Diagnostics2002—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 6 years and passes through 3 companies; a new generation was cleared every 5.3 years on median.
  • None of the 2 ancestors has a recall.

How does its category compare?

All JIS devices

JIS Calibrator, Primary: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JIS

1in 2012

2012: 1
2007high 1 (2012) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JIS

Too few JIS 510(k)s in any year since 2007 to give a median.

Recalls per year · JIS

1in 2022

2008: 12011: 22012: 12016: 12018: 12020: 12021: 12022: 1
2007high 2 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JIS

1in 2024

2010: 12011: 52012: 52013: 12015: 12016: 12017: 32018: 72019: 12020: 12022: 112024: 1
2007high 11 (2022) · low 0 (2007)2025

MAUDE reports naming product code JIS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—10
20090—00
20100—01
20110—25
20121—15
20130—01
20140—00
20150—01
20160—11
20170—03
20180—17
20190—01
20200—11
20210—10
20220—111
20230—00
20240—01
20250—00
20260—0—

What is it indicated for?

VITROS Progesterone Reagent Pack

For in vitro diagnostic use only.

The Vitros Progesterone Reagent Pack quantitatively measures progesterone concentration in human serum and plasma.

VITROS Progesterone Calibrators

For in vitro use in the calibration of the VITROS Immunodiagnostic System for the quantitative measurement of progesterone in human serum and plasma (EDTA or heparin).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K032296: Vitros Immunodiagnostic Products Progestrone Reagent Pack and Calibrators.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K032296

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026