510(k) Report

510(k) · Cleared

Recalled · Class II · 2016

Polestar N-20

K032541510(k) SpecialCleared Sep 12, 200325-day reviewClass II21 CFR 892.1000Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Odin Medical Technologies, Ltd. · LNH System, Nuclear Magnetic Resonance Imaging

Cleared on Sep 12, 2003 as substantially equivalent to K010850 (Odin Medical Technologies, Ltd., 2001) after a 25-day review. Its family tree reaches back 1 generation to 2001. 1 of the 3 devices in its family, counting itself, has a Class I recall. 1 later device descends from it. It has been recalled 2 times.

Decided
Sep 12, 2003
Review
25 days
Class
Class II
Product code
LNH
Recalls
2
Predicates
1

Its longest line of descent runs back 1 generation to K010850 (2001). 1 later device descends from it, 1 citing it directly. 1 of the 3 devices in this family, counting this one, has a Class I recall.

Descendants, by year cleared 2010: 1 descendant clearedK010850 · Polestar N-10 · Odin Medical Technologies, Ltd. · 2001 · Class I recall200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant K010850 · Polestar N-10 · Odin Medical Technologies, Ltd. · 2001 · Class I recall0
  1. Root · 1 generation backK010850 Polestar N-10Odin Medical Technologies, Ltd. · 2001 · Recalled (Class I)
  2. This deviceK032541 Polestar N-20Odin Medical Technologies, Ltd. · 2003
  3. Descendant · cites it directly · 0 of its ownK092308 Polestar, Model N-30Medtronic Navigation Israel, Ltd. · 2010 · Recalled

Class I recalls in this family

Most influential descendants

Showing 1 of 1 · See all
  • K092308Polestar, Model N-30Medtronic Navigation Israel, Ltd. · 2010 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K010850Polestar N-10Odin Medical Technologies, Ltd.2001Class I
0 (this device)K032541Polestar N-20Odin Medical Technologies, Ltd.2003—
+1K092308Polestar, Model N-30Medtronic Navigation Israel, Ltd.20101

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201010
FIG. 1 — Lineage of K032541, 2001–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LNH device

  1. #1 K213693 MAGNETOM Vida with syngo MR XA50Ascore 23.0 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K010850Polestar N-10
Summary page 4
…807.92(a)(6) - Substantial Equivalence Comparison Table: Odin Odin Polestar N-10 (K010850) Polestar N-20 Clinical application Extremities and selected Extremities and selected…
Odin Medical Technologies, Ltd.2001Class I

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K092308Polestar, Model N-30Medtronic Navigation Israel, Ltd.20100

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 20, 2016Class IIZ-2129-2016Process change controlMedtronic Navigation is recalling certain components of the PoleStar system (N20 / N30) because of misplaced ground pins which may cause electrical shock to the user.
Jul 1, 2010Not classifiedZ-2240-2010Device DesignElectronic box on headstrap may overheat, causing burn to patient.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K010850Polestar N-10Odin Medical Technologies, Ltd. · 2001 · Direct predicate · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • Its one ancestor has a recall, Class I.
  • Of its descendants, K092308 (Medtronic Navigation Israel, Ltd., 2010) has gone furthest, with 0 descendants of its own.

How does its category compare?

All LNH devices

LNH System, Nuclear Magnetic Resonance Imaging: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LNH

26in 2025

2007: 122008: 192009: 172010: 122011: 162012: 222013: 192014: 172015: 192016: 202017: 182018: 292019: 262020: 322021: 272022: 302023: 302024: 262025: 262026 (partial year): 24
2007high 32 (2020) · low 12 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LNH

122in 2025

2007: 35 days median2008: 53 days median2009: 70 days median2010: 94 days median2011: 81 days median2012: 89 days median2013: 108 days median2014: 108 days median2015: 140 days median2016: 108 days median2017: 98 days median2018: 128 days median2019: 62 days median2020: 121 days median2021: 87 days median2022: 74 days median2023: 124 days median2024: 104 days median2025: 122 days median2026 (partial year): 126 days median
2007high 140 (2015) · low 35 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LNH

8in 2025

2007: 252008: 122009: 72010: 172011: 112012: 52013: 22014: 132015: 12, 2 Class I2016: 12018: 712019: 52020: 42021: 412022: 132023: 10, 1 Class I2024: 42025: 8, 5 Class I2026 (partial year): 43
2007high 71 (2018) · low 0 (2017)2026

Class I (8 since 2007) Class II/III not classified

Adverse event reports per year · LNH

1,263in 2025

2007: 1142008: 1672009: 1942010: 1652011: 1822012: 1702013: 1072014: 1192015: 1132016: 1352017: 1212018: 1582019: 1582020: 982021: 842022: 1382023: 1592024: 2812025: 1,263
2007high 1,263 (2025) · low 84 (2021)2025

MAUDE reports naming product code LNH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007123525114
2008195312167
200917707194
2010129417165
2011168111182
201222895170
2013191082107
20141710813119
20151914012 (2)113
2016201081135
201718980121
20182912871158
201926625158
202032121498
202127874184
2022307413138
20233012410 (1)159
2024261044281
2025261228 (5)1,263
20262412643—

What is it indicated for?

The Polestar N-20 is a Magnetic Resonance Diagnostic Device intended to produce transverse, sagittal, coronal, and oblique 2D and 3D images of the extremities and selected sections of the head. The images produced by the Polestar N-20 reflect the spatial distribution of protons (Hydrogen Nuclei) exhibiting magnetic resonance. The NMR properties that determine the image appearance are proton density, spin-lattice relaxation time (Tl), spin-spin relaxation…

Read the full statement (123 words)

The Polestar N-20 is a Magnetic Resonance Diagnostic Device intended to produce transverse, sagittal, coronal, and oblique 2D and 3D images of the extremities and selected sections of the head. The images produced by the Polestar N-20 reflect the spatial distribution of protons (Hydrogen Nuclei) exhibiting magnetic resonance. The NMR properties that determine the image appearance are proton density, spin-lattice relaxation time (Tl), spin-spin relaxation time (T2) and T2*.

Anatomical regions: extremities and selected sections of the head.

Nuclei excited: H- 1

Diagnostic uses: T1, T2, T2* and density weighted imaging.

The Polestar N-20 is intended to be used intraoperatively in a standard operating room. When interpreted by trained physicians, the MR images provide information that can be useful in determining a diagnosis.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K032541: Polestar N-20.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K032541

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026