510(k) Report

510(k) · Cleared

Cleared

Micromlc

K032790510(k) SpecialCleared Oct 2, 200324-day reviewClass II21 CFR 892.5710

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Siemens Medical Solutions USA, Inc. · IXI Block, Beam-Shaping, Radiation Therapy

Cleared on Oct 2, 2003 as substantially equivalent to K000349 (Stryker Leibinger, 2000) after a 24-day review. Its family tree reaches back 1 generation to 2000.

Decided
Oct 2, 2003
Review
24 days
Class
Class II
Product code
IXI
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K000349 (2000). No later device cites it as a predicate yet.

K000349 · Motorized Micro Multileaf Collimator · Stryker Leibinger · 2000200020022004
  1. Root · 1 generation backK000349 Motorized Micro Multileaf CollimatorStryker Leibinger · 2000
  2. This deviceK032790 MicromlcSiemens Medical Solutions USA, Inc. · 2003
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K000349Motorized Micro Multileaf CollimatorStryker Leibinger2000—
0 (this device)K032790MicromlcSiemens Medical Solutions USA, Inc.2003—
FIG. 1 — Lineage of K032790, 2000–2003Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IXI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IXI device

  1. #1 K253025 Ricoh 3D for Healthcare Bolusscore 12.9 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K000349Motorized Micro Multileaf Collimator
Summary page 1
…Class II device Product Code: 1x1 Substantial Equivalence Claimed To: Motorized Micro Multileaf Collimator (K000349) Description: The microMLC is a conformal radiation therapy and radiosurgery device that is mounted to a standard ra…
Stryker Leibinger2000—

Also cleared against K000349: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 1 other device also cites its predicate K000349.

How does its category compare?

All IXI devices

IXI Block, Beam-Shaping, Radiation Therapy: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · IXI

2in 2022

2007: 22009: 32011: 22012: 12013: 32022: 22026 (partial year): 1
2007high 3 (2009) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IXI

90in 2013

2009: 78 days median2013: 90 days median
2007high 90 (2013) · low 78 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IXI

2in 2013

2008: 12011: 12012: 12013: 2
2007high 2 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IXI

1in 2016

2010: 12011: 282012: 32013: 22014: 12016: 1
2007high 28 (2011) · low 0 (2007)2025

MAUDE reports naming product code IXI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
20080—10
200937800
20100—01
20112—128
20121—13
201339022
20140—01
20150—00
20160—01
20170—00
20180—00
20190—00
20200—00
20210—00
20222—00
20230—00
20240—00
20250—00
20261—0—

What is it indicated for?

The microMLC is a conformal radiation therapy and radiosurgery device that delivers a shaped X-ray beam from a radiation therapy source. The microMLC is attached to a linear accelerator and consists of a series of pairs of tungsten leaves that collimate the radiation delivery to a target based on a treatment plan generated by planning software. The device is used to assist the clinician in the delivery of well-defined target volumes of radiation while…

Read the full statement (111 words)

The microMLC is a conformal radiation therapy and radiosurgery device that delivers a shaped X-ray beam from a radiation therapy source. The microMLC is attached to a linear accelerator and consists of a series of pairs of tungsten leaves that collimate the radiation delivery to a target based on a treatment plan generated by planning software. The device is used to assist the clinician in the delivery of well-defined target volumes of radiation while sparing the surrounding tissues and organs.

The Siemens Medical Solutions Oncology Care Systems, microMLC. is intended to be used for medical procedures on patients to be prescribed and performed by a suitably trained and certified medical professional.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K032790: Micromlc.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K032790

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026