510(k) · Cleared
Recalled · 2004Aeroneb GO Nebulizer, Model AG-AG2000
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Aerogen, Inc. · CAF Nebulizer (Direct Patient Interface)
Cleared on Nov 21, 2003 as substantially equivalent to K970010 (Fluid Propulsion Technologies, Inc., 1997) and 3 other predicates after a 70-day review. Its family tree reaches back 1 generation to 1992. 1 later device descends from it. It has been recalled once.
- Decided
- Nov 21, 2003
- Review
- 70 days
- Class
- Class II
- Product code
- CAF
- Recalls
- 1
- Predicates
- 4
Its longest line of descent runs back 1 generation to K923024 (1992). 4 ancestors in all. 1 later device descends from it, 1 citing it directly.
Most influential descendants
Showing 1 of 1 · See all- K162041Airworks Nebulizer pe1200mConvexity Scientific, LLC · 2017 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K923024 | NE-U04/NE U04F | Omron Healthcare, Inc. | 1992 | 1 |
| 0 (this device) | K032849 | Aeroneb GO Nebulizer, Model AG-AG2000 | Aerogen, Inc. | 2003 | — |
| +1 | K162041 | Airworks Nebulizer pe1200m | Convexity Scientific, LLC | 2017 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1996 | 1 | 0 |
| 1997 | 1 | 0 |
| 2000 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2017 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in CAF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new CAF device
- #1 K260270 FindAir ONE for pMDI (FAO-MDI-V12-GRE-001)score 13.2 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K970010 | FPT Nebulizer | 1997 |
| * | K003022 | Aeroneb Portable Nebulizer | 2000 |
| * | K963924 | LC Star Reusable Nebulizer 22F50 and LC Star Disposable Nebulizer 22F70Summary page 1…KO03022 Pare Holding Co. Pari LC Star"* Reusable Nebulizer K963924 Omron Healthcare, Inc. Omron MicroAir@Portable Ultrasonic Nebulizer… | 1996 |
| * | K923024 | NE-U04/NE U04FSummary page 1…er K963924 Omron Healthcare, Inc. Omron MicroAir@Portable Ultrasonic Nebulizer K923024 (4) DescriDtion of the device: The Aeroneb Go nebulizer, for use by pediatric and adult patients, is intended to… | 1992 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K162041 | Airworks Nebulizer pe1200m | 2017 | 0 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Sep 7, 2004 | Not classified | Z-0177-05 | Other | The nebulizer can either fail or provide a low flow (partial dose) of medication |
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All CAF devicesCAF Nebulizer (Direct Patient Interface): FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · CAF
7in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · CAF
211in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · CAF
1in 2018
Class I (13 since 2007) Class II/III not classified
Adverse event reports per year · CAF
191in 2025
MAUDE reports naming product code CAF, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 18 | 98 | 1 | 26 |
| 2008 | 12 | 123 | 0 | 11 |
| 2009 | 8 | 163 | 0 | 15 |
| 2010 | 10 | 114 | 0 | 37 |
| 2011 | 10 | 157 | 1 | 237 |
| 2012 | 9 | 126 | 0 | 138 |
| 2013 | 9 | 238 | 0 | 217 |
| 2014 | 9 | 151 | 5 | 123 |
| 2015 | 8 | 186 | 3 | 166 |
| 2016 | 5 | 186 | 1 | 201 |
| 2017 | 8 | 253 | 14 (13) | 256 |
| 2018 | 9 | 161 | 1 | 162 |
| 2019 | 3 | 266 | 0 | 185 |
| 2020 | 6 | 219 | 0 | 117 |
| 2021 | 8 | 324 | 0 | 161 |
| 2022 | 4 | 176 | 0 | 55 |
| 2023 | 8 | 279 | 0 | 107 |
| 2024 | 4 | 251 | 0 | 102 |
| 2025 | 7 | 211 | 0 | 191 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
The Aeroneb Go nebulizer, for use by pediatric and adult patients, is intended to aerosolize physician-prescribed solutions for inhalation that are approved for use with a general-purpose nebulizer.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K032849 · printed Nov 6, 2026
Cite this page
510(k) Report. “K032849: Aeroneb GO Nebulizer, Model AG-AG2000.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K032849
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026