510(k) Report

510(k) · Cleared

Cleared

Cook Coda Balloon Catheter

K032869510(k) TraditionalCleared Nov 19, 200365-day reviewClass II21 CFR 870.1250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cook, Inc. · DQY Catheter, Percutaneous

Cleared on Nov 19, 2003 as substantially equivalent to K002286 (Cook, Inc., 2001) and 1 other predicate after a 65-day review. Its family tree reaches back 1 generation to 2001. 26 later devices descend from it.

Decided
Nov 19, 2003
Review
65 days
Class
Class II
Product code
DQY
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K003495 (2001). 2 ancestors in all. 26 later devices descend from it, 9 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2001: 1 other ancestor2005: 1 descendant cleared2015: 2 descendants cleared2008: 2 descendants cleared2011: 1 descendant cleared2009: 1 descendant cleared2013: 2 descendants cleared2010: 1 descendant cleared2025: 3 descendants cleared2020: 3 descendants cleared2012: 3 descendants cleared2017: 2 descendants cleared2018: 1 descendant cleared2021: 2 descendants cleared2022: 1 descendant cleared2023: 1 descendant clearedK003495 · Ancure Lliac Balloon Catheter · Guidant Cardiac and Vascular Surgery · 2001200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 9 descendants2 generations forward: 8 descendants3 generations forward: 4 descendants4 generations forward: 4 descendants5 generations forward: 1 descendant K003495 · Ancure Lliac Balloon Catheter · Guidant Cardiac and Vascular Surgery · 20010+5
  1. Root · 1 generation backK003495 Ancure Lliac Balloon CatheterGuidant Cardiac and Vascular Surgery · 2001
  2. This deviceK032869 Cook Coda Balloon CatheterCook, Inc. · 2003
  3. Descendant · cites it directly · 11 of its ownK122917 Coda Balloon CatheterCook, Inc. · 2013
  4. Descendant · cites it directly · 11 of its ownK050038 Reliant Stent Graft Balloon CatheterMedtronic Endovascular Innovations · 2005
  5. Descendant · cites it directly · 10 of its ownK150970 Coda LP Balloon CatheterCook Incorporated · 2015
  6. Descendant · cites it directly · 9 of its ownK151821 ER-REBOA CatheterPryor Medical Devices, Inc. · 2015
  7. Descendant · 2 generations on · 8 of its ownK170411 ER-REBOA CatheterPrytime Medical Devices, Inc. · 2017

Showing 5 of 26 descendants. See all descendants

Descendants cleared per year

2005: 12008: 22009: 12010: 12011: 12012: 32013: 22015: 22017: 22018: 12020: 32021: 22022: 12023: 12025: 3
2005high 3 (2012) · low 0 (2006)2026

Most influential descendants

Showing 5 of 26 · See all
  • K122917Coda Balloon CatheterCook, Inc. · 2013 · cites it directly11descendants
  • K050038Reliant Stent Graft Balloon CatheterMedtronic Endovascular Innovations · 2005 · cites it directly11descendants
  • K150970Coda LP Balloon CatheterCook Incorporated · 2015 · cites it directly10descendants
  • K151821ER-REBOA CatheterPryor Medical Devices, Inc. · 2015 · cites it directly9descendants
  • K170411ER-REBOA CatheterPrytime Medical Devices, Inc. · 2017 · 2 generations on8descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K003495Ancure Lliac Balloon CatheterGuidant Cardiac and Vascular Surgery2001—
0 (this device)K032869Cook Coda Balloon CatheterCook, Inc.2003—
+1K122917Coda Balloon CatheterCook, Inc.2013—
+1K050038Reliant Stent Graft Balloon CatheterMedtronic Endovascular Innovations2005—
+1K150970Coda LP Balloon CatheterCook Incorporated2015—
+1K151821ER-REBOA CatheterPryor Medical Devices, Inc.2015—
+2K170411ER-REBOA CatheterPrytime Medical Devices, Inc.2017—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200510
200820
200910
201010
201110
201230
201320
201520
201720
201810
202030
202120
202210
202310
202530
FIG. 1 — Lineage of K032869, 2001–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQY device

  1. #1 K234115 APRO 55 Catheterscore 17.5 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K002286Ldob Occlusion Balloon Catheter
Summary page 1
…OON CATHETER is intended for temporary occlusion of large vessels, or to expand vascular prostheses. Predicate Devices: Predicate devices are the LDOB BALLOON CATHETER (K002286) manufactured by Cook Incorporated (vessel occlusion), and the ILIAC BALLOON CATHETER (K003495) manufactured by Guidant Corporati…
Cook, Inc.2001—
*K003495Ancure Lliac Balloon Catheter
Summary page 1
…eses. Predicate Devices: Predicate devices are the LDOB BALLOON CATHETER (K002286) manufactured by Cook Incorporated (vessel occlusion), and the ILIAC BALLOON CATHETER (K003495) manufactured by Guidant Corporation (prosthesis expansion). Device Description: The COOK CODATMBALLOON CATHETER is a 2-lumen ca…
Guidant Cardiac and Vascular Surgery2001—

Also cleared against K002286: 5 other devices →

What descends from it? (26)

See all 26

9 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K122917Coda Balloon CatheterCook, Inc.201311
K050038Reliant Stent Graft Balloon CatheterMedtronic Endovascular Innovations200511
K150970Coda LP Balloon CatheterCook Incorporated201510
K151821ER-REBOA CatheterPryor Medical Devices, Inc.20159
K110891The Unballoon Non-Occlusive Catheter; the Unballoon Non-Occlusive Modeling CatheterLeMaitre Vascular, Inc.20113
K091624Stent Graft Balloon CatheterVia Biomedical, Inc.20093
K081799Gore Tri-Lobe Balloon CatheterW. L. Gore & Associates, Inc.20082
K101877Occlusion Balloon Catheter Model ObcCook, Inc.20100
K070126Occlusion Balloon CatheterSentreheart, Inc.20080

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.
  • Of its descendants, K122917 (Cook, Inc., 2013) has gone furthest, with 11 descendants of its own.
  • 5 other devices also cite its predicate K002286.

How does its category compare?

All DQY devices

DQY Catheter, Percutaneous: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DQY

21in 2025

2007: 162008: 312009: 372010: 222011: 362012: 302013: 322014: 192015: 272016: 222017: 262018: 252019: 302020: 202021: 182022: 182023: 182024: 162025: 212026 (partial year): 11
2007high 37 (2009) · low 16 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQY

115in 2025

2007: 85 days median2008: 66 days median2009: 73 days median2010: 74 days median2011: 71 days median2012: 87 days median2013: 92 days median2014: 127 days median2015: 118 days median2016: 117 days median2017: 113 days median2018: 106 days median2019: 111 days median2020: 120 days median2021: 81 days median2022: 74 days median2023: 114 days median2024: 87 days median2025: 115 days median2026 (partial year): 30 days median
2007high 127 (2014) · low 66 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQY

1in 2025

2007: 62008: 122009: 172010: 322011: 62012: 22013: 36, 1 Class I2014: 32015: 32016: 22, 7 Class I2017: 82018: 22019: 12020: 22021: 22023: 172024: 12025: 1, 1 Class I2026 (partial year): 2, 1 Class I
2007high 36 (2013) · low 0 (2022)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · DQY

3,056in 2025

2007: 3132008: 4962009: 8192010: 1,2932011: 1,2112012: 1,1912013: 1,3522014: 1,4972015: 2,3372016: 2,2522017: 2,4892018: 2,8552019: 2,9022020: 2,8892021: 3,0062022: 2,6432023: 3,0492024: 3,1902025: 3,056
2007high 3,190 (2024) · low 313 (2007)2025

MAUDE reports naming product code DQY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200716856313
2008316612496
2009377317819
20102274321,293
2011367161,211
2012308721,191
2013329236 (1)1,352
20141912731,497
20152711832,337
20162211722 (7)2,252
20172611382,489
20182510622,855
20193011112,902
20202012022,889
2021188123,006
2022187402,643
202318114173,049
2024168713,190
2025211151 (1)3,056
202611302 (1)—

What is it indicated for?

The COOK CODA BALLOON CATHETER is intended for temporary occlusion of large vessels, or to expand vascular prostheses.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K032869: Cook Coda Balloon Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K032869

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026