Recalled · Class I · 2013Radius Cougar Wire
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Radius Medical Technologies, Inc. · DQX Wire, Guide, Catheter
Cleared on Oct 17, 2003 as substantially equivalent to K970466 (Radius Medical Technologies, Inc., 1997) and 1 other predicate after a 30-day review. Its family tree reaches back 1 generation to 1997. 2 of the 4 devices in its family, counting itself, have a Class I recall. 1 later device descends from it. It has been recalled 2 times, including 2 Class I recalls.
- Decided
- Oct 17, 2003
- Review
- 30 days
- Class
- Class II
- Product code
- DQX
- Recalls
- 2 (2 Class I)
- Predicates
- 2
Its longest line of descent runs back 1 generation to K970466 (1997). 2 ancestors in all. 1 later device descends from it, 1 citing it directly. 2 of the 4 devices in this family, counting this one, have a Class I recall.
- Root · 1 generation backK970466 Radius Ptca GuidewireRadius Medical Technologies, Inc. · 1997 · Recalled (Class I)
- This deviceK032899 Radius Cougar WireRadius Medical Technologies, Inc. · 2003
- Descendant · cites it directly · 0 of its ownK140695 Cougar Guidewire, Zinger Guidwire, Thunder Guidewire, Provia…Medtronic, Inc. · 2014
Class I recalls in this family
- K970466 Radius Ptca Guidewiredirect predicate · 1997
Most influential descendants
Showing 1 of 1 · See all- K140695Cougar Guidewire, Zinger Guidwire, Thunder Guidewire, Provia Guidewire, Intuition…Medtronic, Inc. · 2014 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K970466 | Radius Ptca Guidewire | Radius Medical Technologies, Inc. | 1997 | Class I |
| 0 (this device) | K032899 | Radius Cougar Wire | Radius Medical Technologies, Inc. | 2003 | — |
| +1 | K140695 | Cougar Guidewire, Zinger Guidwire, Thunder Guidewire, Provia Guidewire… | Medtronic, Inc. | 2014 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2001 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2014 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DQX device
- #1 K213854 SavvyWirescore 15.7 · 10 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K970466 | Radius Ptca GuidewireSummary page 1…g E T 0 gas. D. COMPARATIVE INFORMATION The Modified Radius Cougar Wire is substantially equivalent to the currently marketed Radius PTCA Guidewire (K970466) and the Radius Cougar Wire (K011287). E. PERFORMANCE TESTING The following in vitro perfomiance tests were performed… | 1997 |
| * | K011287 | Radius Cougar WireSummary page 1…RMATION The Modified Radius Cougar Wire is substantially equivalent to the currently marketed Radius PTCA Guidewire (K970466) and the Radius Cougar Wire (K011287). E. PERFORMANCE TESTING The following in vitro perfomiance tests were performed on the Modified Radius Cougar Wire:… | 2001 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K140695 | Cougar Guidewire, Zinger Guidwire, Thunder Guidewire, Provia Guidewire, Intuition… | 2014 | 0 |
Has anything in its family been recalled? (2 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Oct 21, 2013 | Class I | Z-0266-2014 | Nonconforming Material/Component | Potential for PTFE (polytetrafluroethylene) coating to delaminate and detach from Guidewire. |
| Oct 21, 2013 | Class I | Z-0261-2014 | Nonconforming Material/Component | Potential for PTFE (polytetrafluroethylene) coating to delaminate and detach from Guidewire. |
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K970466Radius Ptca GuidewireRadius Medical Technologies, Inc. · 1997 · Direct predicate · ◆ on the line of descent in FIG. 12 Class I recalls
What does this lineage say?
How does its category compare?
All DQX devicesDQX Wire, Guide, Catheter: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DQX
10in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DQX
177in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DQX
3in 2024
Class I (8 since 2007) Class II/III not classified
Adverse event reports per year · DQX
2,178in 2025
MAUDE reports naming product code DQX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 14 | 85 | 12 | 760 |
| 2008 | 19 | 87 | 7 | 715 |
| 2009 | 18 | 87 | 49 | 687 |
| 2010 | 21 | 63 | 34 | 987 |
| 2011 | 18 | 43 | 3 | 1,311 |
| 2012 | 20 | 62 | 5 | 1,337 |
| 2013 | 18 | 119 | 7 (4) | 1,474 |
| 2014 | 18 | 103 | 0 | 1,323 |
| 2015 | 15 | 112 | 1 | 1,323 |
| 2016 | 14 | 179 | 2 (2) | 1,466 |
| 2017 | 19 | 85 | 17 | 1,524 |
| 2018 | 19 | 114 | 9 | 1,737 |
| 2019 | 13 | 173 | 2 | 1,679 |
| 2020 | 14 | 106 | 1 (1) | 1,536 |
| 2021 | 6 | 161 | 0 | 1,713 |
| 2022 | 15 | 212 | 0 | 1,647 |
| 2023 | 10 | 136 | 0 | 2,068 |
| 2024 | 11 | 134 | 3 | 2,210 |
| 2025 | 10 | 177 | 0 | 2,178 |
| 2026 | 12 | 145 | 4 (1) | — |
What is it indicated for?
Radius Cougar Wire is intended for placement of balloon dilatation catheters during PTCA andor PTA.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K032899 · printed Nov 6, 2026
Cite this page
510(k) Report. “K032899: Radius Cougar Wire.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K032899
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026