510(k) Report

510(k) · Cleared

Cleared

Randox Uric Acid

K033278510(k) TraditionalCleared Feb 27, 2004140-day reviewClass I21 CFR 862.1775

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Randox Laboratories, Ltd. · CDO Acid, Uric, Uricase (U.V.)

Cleared on Feb 27, 2004 after a 140-day review. FDA’s file for it is a 510(k) statement, which names no predicate.

Decided
Feb 27, 2004
Review
140 days
Class
Class I
Product code
CDO
Recalls
None
Predicates
0

FDA’s file for it is a 510(k) statement, which names no predicate.

FIG. 1 — Lineage of K033278Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CDO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All CDO devices

CDO Acid, Uric, Uricase (U.V.): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CDO

FDA has decided no CDO device since 2007.

Median 510(k) review, days · CDO

Too few CDO 510(k)s in any year since 2007 to give a median.

Recalls per year · CDO

No recall names CDO since 2007.

Adverse event reports per year · CDO

No MAUDE report names CDO since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The Randox Laboratories Limited Uric Acid Test Kit is an in vitro diagnostic reagent for the quantitative determination of uric acid in serum. The method used is based on UV detection. Uric acid, which absorbs light at 293nm, is converted by uricase to allantoin, which is non-absorbing at 293nm. The change in absorbance at 293nm due to the disappearance of uric acid is indirectly proportional to the concentration of uric acid in the sample and is…

Read the full statement (144 words)

The Randox Laboratories Limited Uric Acid Test Kit is an in vitro diagnostic reagent for the quantitative determination of uric acid in serum. The method used is based on UV detection. Uric acid, which absorbs light at 293nm, is converted by uricase to allantoin, which is non-absorbing at 293nm. The change in absorbance at 293nm due to the disappearance of uric acid is indirectly proportional to the concentration of uric acid in the sample and is measured using a bichromatic (293, 700nm) end-point technique.

Uric acid measurements are used in the diagnosis and treatment of numerous renal and metabolic disorders including renal failure, gout, leukemia, psoriasis, starvation or other wasting conditions and of patients receiving cytotoxic drugs.

This application sheet has been developed for the Dade Dimension Clinical Chemistry Analyser and must be used by suitably qualified laboratory personnel under appropriate clinical laboratory conditions.

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K033278: Randox Uric Acid.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K033278

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026