510(k) · Cleared
ClearedTie-in Trapezium
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Wrightmedicaltechnologyinc · KYI Prosthesis, Wrist, Carpal Trapezium
Cleared on Dec 3, 2003 after a 23-day review. The FDA summary names its predicate without a number. 2 later devices descend from it.
- Decided
- Dec 3, 2003
- Review
- 23 days
- Class
- Class II
- Product code
- KYI
- Recalls
- None
- Predicates
- 0
2 later devices descend from it, 2 citing it directly.
- This deviceK033529 Tie-in TrapeziumWrightmedicaltechnologyinc · 2003
- Descendant · cites it directly · 1 of its ownK092548 Extremity Medical Trapezium ProsthesisExtremity Medical, LLC · 2009
- Descendant · cites it directly · 0 of its ownK201072 Ensemble CMC, Size 141, Ensemble CMC, Size 151, Ensemble CMC, Size 161Ensemble Orthopedics, LLC · 2020
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K033529 | Tie-in Trapezium | Wrightmedicaltechnologyinc | 2003 | — |
| +1 | K092548 | Extremity Medical Trapezium Prosthesis | Extremity Medical, LLC | 2009 | — |
| +1 | K201072 | Ensemble CMC, Size 141, Ensemble CMC, Size 151, Ensemble CMC, Size 161 | Ensemble Orthopedics, LLC | 2020 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2009 | 1 | 0 |
| 2020 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KYI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KYI device
- #1 K201072 Ensemble CMC, Size 141, Ensemble CMC, Size…score 1.9 · 6 generations · no Class I recall
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Swanson Trapezium Implant Named without a submission number |
What descends from it? (2)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K092548 (Extremity Medical, LLC, 2009) has gone furthest, with 1 descendant of its own.
How does its category compare?
All KYI devicesKYI Prosthesis, Wrist, Carpal Trapezium: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KYI
1in 2020
2026 to Oct 25, outlined.
Median 510(k) review, days · KYI
Too few KYI 510(k)s in any year since 2007 to give a median.
Recalls per year · KYI
1in 2016
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KYI
1in 2024
MAUDE reports naming product code KYI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 32 |
| 2008 | 0 | — | 0 | 51 |
| 2009 | 1 | — | 0 | 56 |
| 2010 | 0 | — | 2 | 25 |
| 2011 | 2 | — | 0 | 72 |
| 2012 | 0 | — | 0 | 22 |
| 2013 | 0 | — | 0 | 23 |
| 2014 | 0 | — | 0 | 4 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 1 | 3 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 1 | — | 0 | 4 |
| 2019 | 0 | — | 0 | 14 |
| 2020 | 1 | — | 0 | 8 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 1 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
Use of the TIE-INTm Trapezium may be considered in degenerative or post-traumatic disabilities of the thumb basil joint with:
* Localized pain and palpable crepitation during circumduction movement with axial compression of involved thumb ("grind test")
* Decreased motion, decreased pinch and decreased grip strength
* X-ray evidence of arthritic changes of the trapeziometacarpal, trapezioscaphoid, trapeziotrapezoid, and trapezium second metacarpal joints, singly or in combination
* Associated unstable, stiff, or painful distal joints of thumb or swan-neck deformity
The TIE-INTM Trapezium is for single use.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K033529 · printed Nov 5, 2026
Cite this page
510(k) Report. “K033529: Tie-in Trapezium.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K033529
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026