510(k) Report

510(k) · Cleared

Cleared

Medical Image Digitizer, Model 2908

K033637510(k) SpecialCleared Dec 17, 200328-day reviewClass II21 CFR 892.2030

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Array Corp. · LMA Digitizer, Image, Radiological

Cleared on Dec 17, 2003 after a 28-day review. FDA’s file for it is a 510(k) statement, which names no predicate.

Decided
Dec 17, 2003
Review
28 days
Class
Class II
Product code
LMA
Recalls
None
Predicates
0

FDA’s file for it is a 510(k) statement, which names no predicate.

FIG. 1 — Lineage of K033637Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LMA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All LMA devices

LMA Digitizer, Image, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LMA

3in 2013

2009: 12010: 22013: 3
2007high 3 (2013) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LMA

80in 2013

2013: 80 days median
2007high 80 (2013)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LMA

1in 2019

2019: 1
2007high 1 (2019) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LMA

1in 2013

2008: 32012: 12013: 1
2007high 3 (2008) · low 0 (2007)2025

MAUDE reports naming product code LMA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—03
20091—00
20102—00
20110—00
20120—01
201338001
20140—00
20150—00
20160—00
20170—00
20180—00
20190—10
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

Model 2908 is an image scanner which reads black and white Images from transmitted light through an X-ray film and the like, and transfers the images, as the digital data, to a computer. This device has no patient contacting materials and Is Intended to be used by trained personnel only.

The output of the device is to be evaluated by additionally trained personnel capable of sufficient review to afford identification and Intervention In case of malfunction.

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K033637: Medical Image Digitizer, Model 2908.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K033637

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026