510(k) Report

510(k) · Cleared

Recalled · 2005

Vascular Solutions D-Stat 2 Dry Hemostatic Bandage

K033709510(k) SpecialCleared Dec 18, 200322-day reviewClass URecalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Vascular Solutions, Inc. · QSX Hemostatic Wound Dressing With Thrombin Or Other Biologics

Cleared on Dec 18, 2003 after a 22-day review. The FDA summary names its predicate without a number. 1 later device descends from it. It has been recalled once.

Decided
Dec 18, 2003
Review
22 days
Class
Class U
Product code
QSX
Recalls
1
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2004: 1 descendant cleared200020052010201520202025
  1. This deviceK033709 Vascular Solutions D-Stat 2 Dry Hemostatic BandageVascular Solutions, Inc. · 2003
  2. Descendant · cites it directly · 0 of its ownK040118 Vascular Solutions D-Stat Dry Hemostatic Bandage, the D-Stat Radial…Vascular Solutions, Inc. · 2004

Most influential descendants

Showing 1 of 1 · See all
  • K040118Vascular Solutions D-Stat Dry Hemostatic Bandage, the D-Stat Radial Hemostatic Band and…Vascular Solutions, Inc. · 2004 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K033709Vascular Solutions D-Stat 2 Dry Hemostatic BandageVascular Solutions, Inc.2003—
+1K040118Vascular Solutions D-Stat Dry Hemostatic Bandage, the D-Stat Radial Hemostatic…Vascular Solutions, Inc.2004—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200410
FIG. 1 — Lineage of K033709, 2003–2004Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QSX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QSX device

  1. #1 K200720 D-Stat Radial Topical Hemostatscore 0.8 · 5 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Vascular Solutions Inc., D-Stat Dry Hemostatic Bandage
Named without a submission number
—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K040118Vascular Solutions D-Stat Dry Hemostatic Bandage, the D-Stat Radial Hemostatic Band and…Vascular Solutions, Inc.20040

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 9, 2005Not classifiedZ-0144-06OtherA defect affecting the seals of the paper pouch holding the adhesive bandage provided with the D-Stat products was noted during manufacturing. The integrity of the seals of the D-stat Dry pads which are packaged separately in a foil pouch…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K040118 (Vascular Solutions, Inc., 2004) has gone furthest, with 0 descendants of its own.

How does its category compare?

All QSX devices

QSX Hemostatic Wound Dressing With Thrombin Or Other Biologics: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · QSX

1in 2020

2007: 42008: 12009: 12011: 12020: 1
2007high 4 (2007) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QSX

56in 2007

2007: 56 days median
2007high 56 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QSX

No recall names QSX since 2007.

Adverse event reports per year · QSX

No MAUDE report names QSX since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200745600
20081—00
20091—00
20100—00
20111—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20201—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The Vascular Solutions D-Stat 2 Dry Hemostatic Bandage is intended for use

under the direction of a healthcare professional for the local management and

control of bleeding from vascular access sites and percutaneous catheters and

tubes.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K033709: Vascular Solutions D-Stat 2 Dry Hemostatic Bandage.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K033709

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026