510(k) Report

510(k) · Cleared

Recalled · 2005

Groshong NXT Picc Catheters

K034020510(k) SpecialCleared Jan 21, 200428-day reviewClass II21 CFR 880.5970Recalls 4

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

C.R. Bard, Inc. · LJS Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 Days

Cleared on Jan 21, 2004 as substantially equivalent to K023374 (C.R. Bard, Inc., 2002) after a 28-day review. Its family tree reaches back 2 generations to 1991. 1 later device descends from it. It has been recalled 4 times.

Decided
Jan 21, 2004
Review
28 days
Class
Class II
Product code
LJS
Recalls
4
Predicates
1

Its longest line of descent runs back 2 generations to K904558 (1991). 3 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1994: 1 other ancestor2021: 1 descendant clearedK904558 · Dual Lumen 5 FR Perip Cent Ven Cath W/Groshong Val · Davol, Inc. · 1991K023374 · Groshong NXT Dual Lumen Picc Catheters · C.R. Bard, Inc. · 2002 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor 1 generation forward: 1 descendant K023374 · Groshong NXT Dual Lumen Picc Catheters · C.R. Bard, Inc. · 2002 · recalledK904558 · Dual Lumen 5 FR Perip Cent Ven Cath W/Groshong Val · Davol, Inc. · 19910
  1. Root · 2 generations backK904558 Dual Lumen 5 FR Perip Cent Ven Cath W/Groshong ValDavol, Inc. · 1991
  2. 1 generation backK023374 Groshong NXT Dual Lumen Picc CathetersC.R. Bard, Inc. · 2002 · Recalled
  3. This deviceK034020 Groshong NXT Picc CathetersC.R. Bard, Inc. · 2004
  4. Descendant · cites it directly · 0 of its ownK201452 Groshong NXT PICC CatheterC.R. Bard, Inc. · 2021 · Recalled

Most influential descendants

Showing 1 of 1 · See all
  • K201452Groshong NXT PICC CatheterC.R. Bard, Inc. · 2021 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K904558Dual Lumen 5 FR Perip Cent Ven Cath W/Groshong ValDavol, Inc.1991—
−1K023374Groshong NXT Dual Lumen Picc CathetersC.R. Bard, Inc.20025
0 (this device)K034020Groshong NXT Picc CathetersC.R. Bard, Inc.2004—
+1K201452Groshong NXT PICC CatheterC.R. Bard, Inc.202119

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202110
FIG. 1 — Lineage of K034020, 1991–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LJS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LJS device

  1. #1 K241910 Neonav ECG Tip Location Systemscore 18.0 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K023374Groshong NXT Dual Lumen Picc Catheters
Summary page 1
…Class II, 80 LJS - Long Term Intravascular Catheter Classification Panel: General Hospital Premarket Notification: K023374 6.4 Device Description The 4 Fr single lumen silicone Groshong® NXT PICC catheter is a 60 cm, trimmable catheter with…
C.R. Bard, Inc.20025

Also cleared against K023374: 2 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K201452Groshong NXT PICC CatheterC.R. Bard, Inc.20210

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Dec 20, 2005Not classifiedZ-0544-06OtherMultiple pages in the Instructions For Use booklet were missing print. Booklets were missing either pages 1,4,5,8,9,12,13,and 15, or 2,3,6,7,10,11,14, and 15. These pages contain product description, indications, contraindications…
Dec 20, 2005Not classifiedZ-0541-06OtherMultiple pages in the Instructions For Use booklet were missing print. Booklets were missing either pages 1,4,5,8,9,12,13,and 15, or 2,3,6,7,10,11,14, and 15. These pages contain product description, indications, contraindications…
Dec 20, 2005Not classifiedZ-0543-06OtherMultiple pages in the Instructions For Use booklet were missing print. Booklets were missing either pages 1,4,5,8,9,12,13,and 15, or 2,3,6,7,10,11,14, and 15. These pages contain product description, indications, contraindications…
Dec 20, 2005Not classifiedZ-0542-06OtherMultiple pages in the Instructions For Use booklet were missing print. Booklets were missing either pages 1,4,5,8,9,12,13,and 15, or 2,3,6,7,10,11,14, and 15. These pages contain product description, indications, contraindications…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 13 years and passes through 2 companies; a new generation was cleared every 11.8 years on median.
  • 2 of the 3 ancestors have a recall of any class.
  • Of its descendants, K201452 (C.R. Bard, Inc., 2021) has gone furthest, with 0 descendants of its own.
  • 2 other devices also cite its predicate K023374.

How does its category compare?

All LJS devices

LJS Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 Days: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LJS

8in 2025

2007: 142008: 42009: 162010: 92011: 62012: 142013: 142014: 82015: 72016: 92017: 72018: 102020: 22021: 32022: 32023: 42024: 12025: 82026 (partial year): 2
2007high 16 (2009) · low 0 (2019)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LJS

171in 2025

2007: 92 days median2008: 97 days median2009: 70 days median2010: 114 days median2011: 55 days median2012: 77 days median2013: 31 days median2014: 47 days median2015: 71 days median2016: 128 days median2017: 101 days median2018: 148 days median2021: 284 days median2022: 177 days median2023: 47 days median2025: 171 days median
2007high 284 (2021) · low 31 (2013)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LJS

5in 2023

2008: 12009: 12010: 122011: 42012: 402014: 152015: 22016: 182017: 92018: 32021: 12023: 5, 2 Class I2026 (partial year): 8, 1 Class I
2007high 40 (2012) · low 0 (2007)2026

Class I (3 since 2007) Class II/III not classified

Adverse event reports per year · LJS

4,372in 2025

2007: 3922008: 3692009: 3792010: 4952011: 6962012: 5642013: 6802014: 8422015: 1,3062016: 1,1232017: 2,1002018: 2,3242019: 2,0522020: 2,5392021: 3,0842022: 3,2562023: 2,7992024: 4,2432025: 4,372
2007high 4,372 (2025) · low 369 (2008)2025

MAUDE reports naming product code LJS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200714920392
20084971369
200916701379
2010911412495
20116554696
2012147740564
201314310680
201484715842
201577121,306
20169128181,123
2017710192,100
20181014832,324
20190—02,052
20202—02,539
2021328413,084
2022317703,256
20234475 (2)2,799
20241—04,243
2025817104,372
20262—8 (1)—

What is it indicated for?

The Groshong® NXT PICC provides short (less than 30 days) or long (greater than 30 days) term peripheral access to the central venous system for intravenous therapy or blood sampling.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K034020: Groshong NXT Picc Catheters.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K034020

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026