510(k) · Cleared
ClearedRabbit
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Scion International, Inc. · KNW Instrument, Biopsy
Cleared on Apr 1, 2004 as substantially equivalent to K983296 (United States Surgical, A Division of Tyco Healthc, 1999) and 2 other predicates after a 76-day review. Its family tree reaches back 4 generations to 1987.
- Decided
- Apr 1, 2004
- Review
- 76 days
- Class
- Class II
- Product code
- KNW
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 4 generations to K871390 (1987). 7 ancestors in all. No later device cites it as a predicate yet.
- Root · 4 generations backK871390 Bard Biopty Biopsy SystemC.R. Bard, Inc. · 1987
- 3 generations backK963825 Auto Suture* Abbi* SystemUnited States Surgical, A Division of Tyco Healthc · 1996
- 2 generations backK983296 Auto Suture Abbi SystemUnited States Surgical, A Division of Tyco Healthc · 1999
- 1 generation backK011575 22MM Siteselect Breast Biopsy Device Model SSD022Imagyn Surgical · 2001
- This deviceK040087 RabbitScion International, Inc. · 2004
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K871390 | Bard Biopty Biopsy System | C.R. Bard, Inc. | 1987 | — |
| −3 | K963825 | Auto Suture* Abbi* System | United States Surgical, A Division of Tyco Healthc | 1996 | — |
| −2 | K983296 | Auto Suture Abbi System | United States Surgical, A Division of Tyco Healthc | 1999 | — |
| −1 | K011575 | 22MM Siteselect Breast Biopsy Device Model SSD022 | Imagyn Surgical | 2001 | — |
| 0 (this device) | K040087 | Rabbit | Scion International, Inc. | 2004 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1998 | 1 | 0 |
| 1999 | 1 | 0 |
| 2001 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KNW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KNW device
- #1 K260572 Marrow Marxmanscore 14.5 · 10 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K983296 | Auto Suture Abbi SystemSummary page 1…iopsy Devices to which substantial equivalence is claimed: 5 10(K) ft Device Manufacture K983296 Auto Suture ABBI System U.S. Surgical Corporation K01 1575 SiteSelect Breast… | 1999 |
| * | K011575 | 22MM Siteselect Breast Biopsy Device Model SSD022Summary page 1…Device Manufacture K983296 Auto Suture ABBI System U.S. Surgical Corporation K01 1575 SiteSelect Breast Biopsy Device Imagyn Surgical K003297 Mammotomne… | 2001 |
| * | K003297 | Mammotome Hand Held Probe, Model MHH8Summary page 1…ture ABBI System U.S. Surgical Corporation K01 1575 SiteSelect Breast Biopsy Device Imagyn Surgical K003297 Mammotomne Eth icon Device Description: The Candidate Device is a coaxial breast biopsy… | 2001 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 17 years and passes through 4 companies; a new generation was cleared every 2.6 years on median.
- None of the 7 ancestors has a recall.
- 3 other devices also cite its predicate K983296.
How does its category compare?
All KNW devicesKNW Instrument, Biopsy: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KNW
12in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KNW
178in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KNW
1in 2024
Class I (4 since 2007) Class II/III not classified
Adverse event reports per year · KNW
1,667in 2025
MAUDE reports naming product code KNW, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 6 | 94 | 1 | 766 |
| 2008 | 4 | 53 | 7 | 363 |
| 2009 | 6 | 35 | 3 | 351 |
| 2010 | 3 | 57 | 2 | 162 |
| 2011 | 10 | 64 | 5 | 67 |
| 2012 | 7 | 94 | 1 | 93 |
| 2013 | 3 | 100 | 1 (1) | 98 |
| 2014 | 8 | 95 | 3 | 193 |
| 2015 | 10 | 106 | 0 | 591 |
| 2016 | 9 | 127 | 5 | 297 |
| 2017 | 8 | 90 | 1 | 760 |
| 2018 | 7 | 71 | 0 | 1,012 |
| 2019 | 5 | 94 | 4 | 4,195 |
| 2020 | 8 | 92 | 0 | 5,120 |
| 2021 | 9 | 54 | 3 | 1,020 |
| 2022 | 8 | 203 | 3 | 535 |
| 2023 | 7 | 164 | 2 | 931 |
| 2024 | 5 | 114 | 1 | 1,283 |
| 2025 | 12 | 178 | 0 | 1,667 |
| 2026 | 7 | 29 | 4 (3) | — |
What is it indicated for?
The Rabbit is indicated to provide breast tissue samples for diagnostic sampling of breast abnormalities. It is designed to provide breast tissue for histologic examination with partial or complete removal of the imaged abnormality.
The extent of histologic abnormality cannot be reliably determined from its mammographic appearance. Therefore, the extent of removal of the imaged evidence of an abnormality does not predict the extent of removal of a histologic abnormality (e.g., malignancy). When the sampled abnormality is not histologically benign, it is essential that the tissue margins be examined for completeness of removal using standard surgical procedures.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K040087 · printed Nov 4, 2026
Cite this page
510(k) Report. “K040087: Rabbit.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K040087