510(k) Report

510(k) · Cleared

Cleared

Fibrex Catheter Patency Device

K040427510(k) TraditionalCleared May 3, 200474-day reviewClass II21 CFR 880.5200

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Medical Device Technologies, Inc. · FOZ Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days

Cleared on May 3, 2004 as substantially equivalent to K021606 (Medical Device Technologies, Inc., 2002) after a 74-day review. Its family tree reaches back 3 generations to 1990.

Decided
May 3, 2004
Review
74 days
Class
Class II
Product code
FOZ
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K901502 (1990). 7 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 3 generations backK901502 Amplatz Goose-Neck SnareMicrovena Corp. · 1990 · Recalled
  2. 2 generations backK972511 Amplatz Goose Neck Snare Kit/ CatheterMicrovena Corp. · 1998 · Recalled
  3. 1 generation backK021606 EN-Snare Endovascular Snare and CatheterMedical Device Technologies, Inc. · 2002
  4. This deviceK040427 Fibrex Catheter Patency DeviceMedical Device Technologies, Inc. · 2004
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K901502Amplatz Goose-Neck SnareMicrovena Corp.19901
−2K972511Amplatz Goose Neck Snare Kit/ CatheterMicrovena Corp.19981
−1K021606EN-Snare Endovascular Snare and CatheterMedical Device Technologies, Inc.2002—
0 (this device)K040427Fibrex Catheter Patency DeviceMedical Device Technologies, Inc.2004—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199320
199810
FIG. 1 — Lineage of K040427, 1990–2004Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FOZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FOZ device

  1. #1 K243403 BD Nexiva™ Closed IV Catheter Systemscore 14.8 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K021606EN-Snare Endovascular Snare and Catheter
Summary page 1
…Product Name 510(k) No. Medical Device Technologies En-Snare Tm Endovascular Snare and Catheter K02 1606 DESCRIPTION OF DEVICE: The FibreXTM Catheter Patency Device is a tni-axial delivery catheter assembly comprised of an outer cat…
Medical Device Technologies, Inc.2002—

Also cleared against K021606: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 2 companies; a new generation was cleared every 4.2 years on median.
  • 2 of the 7 ancestors have a recall of any class.
  • 1 other device also cites its predicate K021606.

How does its category compare?

All FOZ devices

FOZ Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FOZ

11in 2025

2007: 62008: 92009: 92010: 32011: 62012: 132013: 42014: 92015: 102016: 92017: 92018: 12019: 82020: 102021: 42022: 82023: 92024: 62025: 112026 (partial year): 7
2007high 13 (2012) · low 1 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FOZ

91in 2025

2007: 159 days median2008: 103 days median2009: 30 days median2010: 28 days median2011: 132 days median2012: 122 days median2013: 104 days median2014: 99 days median2015: 107 days median2016: 63 days median2017: 51 days median2019: 140 days median2020: 191 days median2021: 242 days median2022: 183 days median2023: 129 days median2024: 190 days median2025: 91 days median2026 (partial year): 203 days median
2007high 242 (2021) · low 28 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FOZ

4in 2023

2007: 162009: 232010: 1152013: 22014: 42016: 3, 1 Class I2017: 222018: 42019: 32020: 32021: 12022: 4, 2 Class I2023: 4, 2 Class I2026 (partial year): 2
2007high 115 (2010) · low 0 (2008)2026

Class I (5 since 2007) Class II/III not classified

Adverse event reports per year · FOZ

5,110in 2025

2007: 3742008: 4222009: 5082010: 3702011: 7862012: 5602013: 6402014: 8152015: 7292016: 9252017: 1,9662018: 3,3052019: 4,3652020: 3,7972021: 4,6742022: 4,1332023: 4,4302024: 4,7722025: 5,110
2007high 5,110 (2025) · low 370 (2010)2025

MAUDE reports naming product code FOZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007615916374
200891030422
200993023508
2010328115370
201161320786
2012131220560
201341042640
20149994815
2015101070729
20169633 (1)925
2017951221,966
20181—43,305
2019814034,365
20201019133,797
2021424214,674
202281834 (2)4,133
202391294 (2)4,430
2024619004,772
2025119105,110
202672032—

What is it indicated for?

The FibrexTM Catheter Patency Device is intended to disrupt fibrin sheath formation on both the external and internal surface of vascular access catheters, thus restoring functional patency.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K040427: Fibrex Catheter Patency Device.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K040427

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026