510(k) Report

510(k) · Cleared

Cleared

Ceraform Bone Void Filler

K040669510(k) SpecialCleared May 3, 200449-day reviewClass II21 CFR 888.3045

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Teknimed, S.A. · MQV Filler, Bone Void, Calcium Compound

Cleared on May 3, 2004 as substantially equivalent to K031826 (Teknimed, S.A., 2003) after a 49-day review. Its family tree reaches back 3 generations to 2000. 1 later device descends from it.

Decided
May 3, 2004
Review
49 days
Class
Class II
Product code
MQV
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K994337 (2000). 1 later device descends from it, 1 citing it directly.

  1. Root · 3 generations backK994337 Vitoss Scaffold Synthetic Cancellous Bone Void FillerOrthovita Co. · 2000
  2. 2 generations backK021963 Biosorb Resorbable Void FillerSciences ET Bio Materiaux (Sbm) · 2003 · Recalled
  3. 1 generation backK031826 TRIHA +Teknimed, S.A. · 2003 · Recalled
  4. This deviceK040669 Ceraform Bone Void FillerTeknimed, S.A. · 2004
  5. Descendant · cites it directly · 0 of its ownK042911 Cementek LVTeknimed, S.A. · 2004

Most influential descendants

Showing 1 of 1 · See all
  • K042911Cementek LVTeknimed, S.A. · 2004 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K994337Vitoss Scaffold Synthetic Cancellous Bone Void FillerOrthovita Co.2000—
−2K021963Biosorb Resorbable Void FillerSciences ET Bio Materiaux (Sbm)20031
−1K031826TRIHA +Teknimed, S.A.20031
0 (this device)K040669Ceraform Bone Void FillerTeknimed, S.A.2004—
+1K042911Cementek LVTeknimed, S.A.2004—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200410
FIG. 1 — Lineage of K040669, 2000–2004Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQV? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQV device

  1. #1 K232315 Catalyst Bone Void Fillerscore 25.2 · 25 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K031826TRIHA +
Summary page 1
…Filler, calcium sulfate, preformed pellets per 21 CFR Sec. 888.3045 Equivalent Device Ceraform Bone Void Filler is a modification to Teknimed's TRIHA+ Bone Void Filler (K031826). Device Description Ceraform Bone Void Filler is an osseo-conductive macroporous implant made of synthetic beta tri-calcium pho…
Teknimed, S.A.20031

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K042911Cementek LVTeknimed, S.A.20040

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 4 years and passes through 3 companies; a new generation was cleared every 10 months on median.
  • 2 of the 3 ancestors have a recall of any class.
  • Of its descendants, K042911 (Teknimed, S.A., 2004) has gone furthest, with 0 descendants of its own.

How does its category compare?

All MQV devices

MQV Filler, Bone Void, Calcium Compound: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MQV

14in 2025

2007: 352008: 322009: 232010: 172011: 162012: 92013: 122014: 202015: 182016: 82017: 172018: 232019: 132020: 152021: 82022: 92023: 212024: 282025: 142026 (partial year): 5
2007high 35 (2007) · low 8 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQV

57in 2025

2007: 144 days median2008: 102 days median2009: 180 days median2010: 147 days median2011: 92 days median2012: 107 days median2013: 197 days median2014: 153 days median2015: 184 days median2016: 214 days median2017: 124 days median2018: 124 days median2019: 90 days median2020: 132 days median2021: 88 days median2022: 118 days median2023: 74 days median2024: 55 days median2025: 57 days median2026 (partial year): 96 days median
2007high 214 (2016) · low 55 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQV

1in 2025

2007: 52008: 32009: 12011: 62012: 32013: 22016: 12017: 12018: 22020: 12023: 32024: 22025: 12026 (partial year): 4
2007high 6 (2011) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQV

57in 2025

2007: 672008: 712009: 812010: 682011: 1142012: 1492013: 2232014: 1112015: 1252016: 1062017: 1072018: 862019: 652020: 1262021: 1012022: 472023: 1202024: 682025: 57
2007high 223 (2013) · low 47 (2022)2025

MAUDE reports naming product code MQV, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735144567
200832102371
200923180181
201017147068
201116926114
201291073149
2013121972223
2014201530111
2015181840125
201682141106
2017171241107
201823124286
20191390065
2020151321126
20218880101
20229118047
202321743120
20242855268
20251457157
20265964—

What is it indicated for?

Ceraform Bone Void Filler is intended for use only as bone void filler for voids or gaps that are not intrinsic to the stability of the bony structure. Ceraform Bone Void Filler is indicated for use in the treatment of surgically created osseous defects or osseous defects created from traumatic injury to bone. Ceraform Bone Void Filler should not be used to treat large defects that in the surgeon's opinion would fail to heal spontaneously. Ceraform Bone…

Read the full statement (120 words)

Ceraform Bone Void Filler is intended for use only as bone void filler for voids or gaps that are not intrinsic to the stability of the bony structure. Ceraform Bone Void Filler is indicated for use in the treatment of surgically created osseous defects or osseous defects created from traumatic injury to bone. Ceraform Bone Void Filler should not be used to treat large defects that in the surgeon's opinion would fail to heal spontaneously.

Ceraform Bone Void Filler is intended to be gently packed into voids or gaps in the skeletal system (i.e. extremities, spine, and pelvis). Following placement in the bony voids or gap, the calcium phosphate scaffold resorbs and is replaced with bone during the healing process.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K040669: Ceraform Bone Void Filler.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K040669

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026