510(k) · Cleared
ClearedPorta Reflex
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Wieland Dental + Technik GmbH & Co. KG · EJT Alloy, Gold-Based Noble Metal
Cleared on May 27, 2004 as substantially equivalent to K023389 (Wieland Dental + Technik GmbH & Co. KG, 2002) after a 73-day review. Its family tree reaches back 2 generations to 1994.
- Decided
- May 27, 2004
- Review
- 73 days
- Class
- Class II
- Product code
- EJT
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K935507 (1994). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in EJT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K023389 | Porta Geo TISummary page 1…EJT C.D.R section: 872.3060 Classification: Class II Legally marketed equivalent device: Porta Geo Ti 510(k) number. K 023389 Device description Porta Reflex is an extra-hard gold-platinum ceramic alloy with high contents of noble metals (97,7%), inte… | 2002 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 10 years and passes through 2 companies; a new generation was cleared every 8.9 years on median.
- None of the 2 ancestors has a recall.
How does its category compare?
All EJT devicesEJT Alloy, Gold-Based Noble Metal: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · EJT
FDA has decided no EJT device since 2007.
Median 510(k) review, days · EJT
Too few EJT 510(k)s in any year since 2007 to give a median.
Recalls per year · EJT
No recall names EJT since 2007.
Adverse event reports per year · EJT
1in 2017
MAUDE reports naming product code EJT, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 1 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 1 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 1 |
| 2017 | 0 | — | 0 | 1 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
Porta Reflex is a gold-platinum alloy that can be used by dental technicians to fabricate dental appliances for patients.
It is intended for manufacturing
• Inlays/ Onlays
- Partial crowns
• Crowns
Short span bridges
* Long span bridges
* Removable partials
and can be used for
Telescopic and milling work
Porta Reflex can be veneered with suitable dental ceramics as well as with dental-composites.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K040672 · printed Nov 3, 2026
Cite this page
510(k) Report. “K040672: Porta Reflex.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K040672
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026