510(k) · Cleared
ClearedAladyn Rigid Spine Plate
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Scient'X · MNH Orthosis, Spondylolisthesis Spinal Fixation
Cleared on Jun 17, 2004 as substantially equivalent to K990721 (Scien'Tx USA, Inc., 1999) and 1 other predicate after an 86-day review. Its family tree reaches back 5 generations to 1990.
- Decided
- Jun 17, 2004
- Review
- 86 days
- Class
- Class II
- Product code
- MNH
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 5 generations to K901587 (1990). 28 ancestors in all. No later device cites it as a predicate yet.
- Root · 5 generations backK901587 TSRH Sacral L-ConnectorDanek Medical, Inc. · 1990
- 4 generations backK950099 Synergy (TM) TI Posterior Spinal SystemBuckman Co., Inc. · 1997
- 3 generations backK973836 Synergy 6.35MM SS Rod with Screws for Anterior Use, Part of the…Cross Medical Products, Inc. · 1998
- 2 generations backK980484 Aesculap Spine System EvolutionAesculap, Inc. · 1998
- 1 generation backK990118 Isobar Spinal SystemScien'Tx USA, Inc. · 1999
- This deviceK040747 Aladyn Rigid Spine PlateScient'X · 2004
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −5 | K901587 | TSRH Sacral L-Connector | Danek Medical, Inc. | 1990 | — |
| −4 | K950099 | Synergy (TM) TI Posterior Spinal System | Buckman Co., Inc. | 1997 | — |
| −3 | K973836 | Synergy 6.35MM SS Rod with Screws for Anterior Use, Part of the Cross… | Cross Medical Products, Inc. | 1998 | — |
| −2 | K980484 | Aesculap Spine System Evolution | Aesculap, Inc. | 1998 | — |
| −1 | K990118 | Isobar Spinal System | Scien'Tx USA, Inc. | 1999 | — |
| 0 (this device) | K040747 | Aladyn Rigid Spine Plate | Scient'X | 2004 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1990 | 1 | 0 |
| 1992 | 5 | 0 |
| 1993 | 2 | 0 |
| 1994 | 2 | 0 |
| 1995 | 3 | 0 |
| 1996 | 4 | 0 |
| 1997 | 2 | 0 |
| 1998 | 2 | 0 |
| 1999 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MNH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K990721 | Isolock Spinal SystemSummary page 1…cation name Spondylolisthesis spinal fixation device system Pedicle screw spinal system Equivalent Device The Aladyn Rigid Spine Plate is a modification to the ISOLOCK (K990721) and ISOBAR (K9901 18) Pedicle Screw Systems. Device Description The Aladyn Rigid Spine Plate consists of plates, pedicle screws… | 1999 |
| * | K990118 | Isobar Spinal SystemSummary page 1…isthesis spinal fixation device system Pedicle screw spinal system Equivalent Device The Aladyn Rigid Spine Plate is a modification to the ISOLOCK (K990721) and ISOBAR (K9901 18) Pedicle Screw Systems. Device Description The Aladyn Rigid Spine Plate consists of plates, pedicle screws and a polyaxial nut.… | 1999 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 14 years and passes through 6 companies; a new generation was cleared every 1.1 years on median.
- None of the 28 ancestors has a recall.
- 1 other device also cites its predicate K990721.
How does its category compare?
All MNH devicesMNH Orthosis, Spondylolisthesis Spinal Fixation: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MNH
8in 2016
2026 to Oct 25, outlined.
Median 510(k) review, days · MNH
93in 2016
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MNH
1in 2016
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MNH
89in 2025
MAUDE reports naming product code MNH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 5 | 123 | 0 | 18 |
| 2008 | 13 | 65 | 0 | 30 |
| 2009 | 13 | 151 | 7 | 45 |
| 2010 | 10 | 106 | 0 | 59 |
| 2011 | 17 | 171 | 0 | 107 |
| 2012 | 7 | 93 | 1 | 433 |
| 2013 | 10 | 124 | 1 | 464 |
| 2014 | 12 | 140 | 0 | 286 |
| 2015 | 10 | 99 | 0 | 152 |
| 2016 | 8 | 93 | 1 | 216 |
| 2017 | 0 | — | 0 | 174 |
| 2018 | 0 | — | 0 | 129 |
| 2019 | 0 | — | 0 | 403 |
| 2020 | 0 | — | 0 | 432 |
| 2021 | 0 | — | 0 | 531 |
| 2022 | 0 | — | 0 | 265 |
| 2023 | 0 | — | 0 | 121 |
| 2024 | 0 | — | 0 | 302 |
| 2025 | 0 | — | 0 | 89 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The Aladyn Rigid Spine Plate is a pedicle screw system intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed…
Read the full statement (125 words)
The Aladyn Rigid Spine Plate is a pedicle screw system intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudarthrosis).
As a pedicle screw system Aladyn Rigid Spine Plate is indicated for the treatment of severe spondylolisthesis (Grades 3 and 4) of the L5-S1 vertebra in skeletally mature patients receiving fusion by autogenous bone graft having implants attached to the lumnbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K040747 · printed Nov 5, 2026
Cite this page
510(k) Report. “K040747: Aladyn Rigid Spine Plate.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K040747
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026