Partners IN Biomaterials, Inc. · LZU Plug, Punctum

Cleared on Nov 16, 2004 as substantially equivalent to K022043 (Medennium, Inc., 2002) and 1 other predicate after a 222-day review. Its family tree reaches back 1 generation to 1995. 1 later device descends from it.

Decided
Nov 16, 2004
Review
222 days
Class
Class U
Product code
LZU
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K946357 (1995). 2 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2002: 1 other ancestor2022: 1 descendant clearedK946357 · Collagen Intracanalicular Plug · Oasis Medical, Inc. · 19951995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 1 descendant K946357 · Collagen Intracanalicular Plug · Oasis Medical, Inc. · 19950
  1. Root · 1 generation backK946357 Collagen Intracanalicular PlugOasis Medical, Inc. · 1995
  2. This deviceK040912 Hydrogel Canalicular PlugPartners IN Biomaterials, Inc. · 2004
  3. Descendant · cites it directly · 0 of its ownK222164 Visant Medical Canalicular PlugVisant Medical, Inc. · 2022

Most influential descendants

Showing 1 of 1 · See all
  • K222164Visant Medical Canalicular PlugVisant Medical, Inc. · 2022 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K946357Collagen Intracanalicular PlugOasis Medical, Inc.1995—
0 (this device)K040912Hydrogel Canalicular PlugPartners IN Biomaterials, Inc.2004—
+1K222164Visant Medical Canalicular PlugVisant Medical, Inc.2022—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
FIG. 1 — Lineage of K040912, 1995–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LZU? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LZU device

  1. #1 K241229 Hello,eyes® BIO Plugscore 8.5 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K022043Smart Plug, Model 500; Smartplug Forceps, Model 502; Push Rod, Model 503
Summary page 4
…The proposed device, the Hydrogel Canalicular Plug, claims substantial equivalence in intended use and method of operation to the Medennium Smart Plug (K022043). Both plugs are a one-size-fits-all design that change shape upon insertion in to the canaliculus in order to…
Medennium, Inc.2002—
*K946357Collagen Intracanalicular Plug
Summary page 4
…prior to insertion into the canaliculus. The Hydrogel Canalicular Plug also claims substantial equivalence to collagen plugs marketed by Oasis Medical (K946357), and others, in both size and function. Both of these plugs are approximately 0.3mm diameter by 2.5mm long. W…
Oasis Medical, Inc.1995—

Also cleared against K022043: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K222164Visant Medical Canalicular PlugVisant Medical, Inc.20220

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.
  • Of its descendants, K222164 (Visant Medical, Inc., 2022) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K022043.

How does its category compare?

All LZU devices

LZU Plug, Punctum: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LZU

1in 2024

2009: 12014: 32015: 12016: 12017: 12019: 12022: 22024: 1
2007high 3 (2014) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LZU

148in 2014

2014: 148 days median
2007high 148 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LZU

2in 2022

2022: 2
2007high 2 (2022) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LZU

3in 2025

2007: 102008: 122009: 112010: 52011: 62012: 72013: 172014: 102015: 12017: 32018: 22020: 22023: 52024: 12025: 3
2007high 17 (2013) · low 0 (2016)2025

MAUDE reports naming product code LZU, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—010
20080—012
20091—011
20100—05
20110—06
20120—07
20130—017
20143148010
20151—01
20161—00
20171—03
20180—02
20191—00
20200—02
20210—00
20222—20
20230—05
20241—01
20250—03
20260—0—

What is it indicated for?

The Hydrogel Canalicular Plug is intended for use in patients experiencing dry eye symptoms such as redness, burning, reflex tearing, itching, or foreign body sensations, which can be relieved by blocking of the punctum.

The Hydrogel Canalicular Plug may be used in the treatment of dry eye syndrome and the dry eye component of various ocular surface diseases.

When indicated, the Hydrogel Canalicular Plug may be used after surgery of the eye to prevent complications due to dry eye and to enhance the retention of ocular medications on the eye. Patients experiencing dry eye related contact lens problems may also be aided by the Hydrogel Canalicular Plug.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K040912: Hydrogel Canalicular Plug.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K040912

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026