510(k) Report

510(k) · Cleared

Cleared

CDS Hematology Calibrator (CDS Cal)

K041130510(k) AbbreviatedCleared Jun 10, 200441-day reviewClass II21 CFR 864.8165

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Clinical Diagnostic Solutions, Inc. · KRZ Calibrator For Hemoglobin And Hematocrit Measurement

Cleared on Jun 10, 2004 after a 41-day review. FDA’s file for it is a 510(k) statement, which names no predicate.

Decided
Jun 10, 2004
Review
41 days
Class
Class II
Product code
KRZ
Recalls
None
Predicates
0

FDA’s file for it is a 510(k) statement, which names no predicate.

FIG. 1 — Lineage of K041130Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KRZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All KRZ devices

KRZ Calibrator For Hemoglobin And Hematocrit Measurement: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KRZ

FDA has decided no KRZ device since 2007.

Median 510(k) review, days · KRZ

Too few KRZ 510(k)s in any year since 2007 to give a median.

Recalls per year · KRZ

1in 2011

2011: 1
2007high 1 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KRZ

1in 2022

2007: 22018: 22022: 1
2007high 2 (2007) · low 0 (2008)2025

MAUDE reports naming product code KRZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—02
20080—00
20090—00
20100—00
20110—10
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—02
20190—00
20200—00
20210—00
20220—01
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The CDS Hematology Calibrator for red cell, white cell and platelet counting is a device that resembles red cells, white cells and platelets in whole blood specimens and is intended to serve as a calibration standard for automated hematology analyzers, including Beckman Coulter S Plus IL-VI series, STKR, JS, JR, ST and JT series, STKS, MAXM, HmX, Gen.S, MD series, OnyX, T series and AT and AT diff series analyzers; the Abbott Cell-Dyn 1400, 1500, 1600…

Read the full statement (118 words)

The CDS Hematology Calibrator for red cell, white cell and platelet counting is a device that resembles red cells, white cells and platelets in whole blood specimens and is intended to serve as a calibration standard for automated hematology analyzers, including Beckman Coulter S Plus IL-VI series, STKR, JS, JR, ST and JT series, STKS, MAXM, HmX, Gen.S, MD series, OnyX, T series and AT and AT diff series analyzers; the Abbott Cell-Dyn 1400, 1500, 1600 and 1700 analyzers; and the Danam EXCEL 16 and EXCEL 22 analyzers, intended to count red cells, white cells and platelets. It is a suspension of particles or cells whose size, shape, concentration and other characteristics have been precisely and accurately determined.

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K041130: CDS Hematology Calibrator (CDS Cal).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K041130

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026