510(k) Report

510(k) · Cleared

Cleared

Duralite-GL

K041262510(k) TraditionalCleared Aug 13, 200494-day reviewClass II21 CFR 878.4810

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Laser Scientific · GEX Powered Laser Surgical Instrument

Cleared on Aug 13, 2004 as substantially equivalent to K024371 (Candela Corp., 2003) and 4 other predicates after a 94-day review. Its family tree reaches back 6 generations to 1996.

Decided
Aug 13, 2004
Review
94 days
Class
Class II
Product code
GEX
Recalls
None
Predicates
6

Its longest line of descent runs back 6 generations to K963094 (1996). 18 ancestors in all, the oldest K950019 (1995). No later device cites it as a predicate yet.

  1. Root · 6 generations backK963094 Cynosure Photogenica LP Dermatological Vascular Lesion LaserCynosure, Inc. · 1996
  2. 5 generations backK972767 Candela Gentlelase GL Dermatological Vascular Lesion LaserCandela Corp. · 1997 · Recalled
  3. 4 generations backK974381 Candela Gentlelase GL Dermatological LaserCandela Corp. · 1998
  4. 3 generations backK981351 Candela Gentlelase GL Dermatological LaserCandela Corp. · 1998
  5. 2 generations backK994260 Candela Gentlelase GL Dermatological LaserCandela Corp. · 2000
  6. 1 generation backK024335 Candela Gentlelase Family of Laser SystemsCandela Corp. · 2003 · Recalled
  7. This deviceK041262 Duralite-GLLaser Scientific · 2004
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K963094Cynosure Photogenica LP Dermatological Vascular Lesion LaserCynosure, Inc.1996—
−5K972767Candela Gentlelase GL Dermatological Vascular Lesion LaserCandela Corp.19971
−4K974381Candela Gentlelase GL Dermatological LaserCandela Corp.1998—
−3K981351Candela Gentlelase GL Dermatological LaserCandela Corp.1998—
−2K994260Candela Gentlelase GL Dermatological LaserCandela Corp.2000—
−1K024335Candela Gentlelase Family of Laser SystemsCandela Corp.20031
0 (this device)K041262Duralite-GLLaser Scientific2004—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
199610
199740
199810
199920
200110
200320
FIG. 1 — Lineage of K041262, 1996–2004Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GEX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GEX device

  1. #1 K222064 The Alma Soprano Titaniumscore 38.1 · 24 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (6)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.

TypeNumberDeviceApplicantDecidedRecalls
*K024371Candela Gentle Lase Family of Laser System
Summary page 1
…al, Powered, laser 79-GEX, 21 CFR 878-48 Legally Marketed Predicate Device: GentleLASE Plus Fiber Optic cleared under K024371, K024260, K024335, K994260, K98460 IK003460 Description of the DuraLITE-GL…
Candela Corp.2003—
*K024260Candela Gentlelase Family of Laser Systems
Summary page 1
…ed, laser 79-GEX, 21 CFR 878-48 Legally Marketed Predicate Device: GentleLASE Plus Fiber Optic cleared under K024371, K024260, K024335, K994260, K98460 IK003460 Description of the DuraLITE-GL The Du…
Candela Corp.20031
*K024335Candela Gentlelase Family of Laser Systems
Summary page 1
…79-GEX, 21 CFR 878-48 Legally Marketed Predicate Device: GentleLASE Plus Fiber Optic cleared under K024371, K024260, K024335, K994260, K98460 IK003460 Description of the DuraLITE-GL The DuraLITE-GL is an exact replacament campoatxt for the…
Candela Corp.20031
*K994260Candela Gentlelase GL Dermatological Laser
Summary page 1
…21 CFR 878-48 Legally Marketed Predicate Device: GentleLASE Plus Fiber Optic cleared under K024371, K024260, K024335, K994260, K98460 IK003460 Description of the DuraLITE-GL The DuraLITE-GL is an exact replacament campoatxt for the…
Candela Corp.2000—
Kept off the family treeK984606GentleLASE Plus Fiber Optic
Not matched in our reading of the summary (scans can blur digits), so it is kept off the family tree
*K003460Palomar Clear Light ND: Yag Laser System
Summary page 1
…gally Marketed Predicate Device: GentleLASE Plus Fiber Optic cleared under K024371, K024260, K024335, K994260, K98460 IK003460 Description of the DuraLITE-GL The DuraLITE-GL is an exact replacament campoatxt for the…
Palomar Medical Technologies, Inc.2001—

Also cleared against K024371: 5 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 8 years and passes through 3 companies; a new generation was cleared every 1.4 years on median.
  • 3 of the 18 ancestors have a recall of any class.
  • 5 other devices also cite its predicate K024371.

How does its category compare?

All GEX devices

GEX Powered Laser Surgical Instrument: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GEX

83in 2025

2007: 732008: 1072009: 692010: 502011: 412012: 452013: 462014: 612015: 472016: 512017: 672018: 512019: 412020: 522021: 532022: 602023: 522024: 822025: 832026 (partial year): 57
2007high 107 (2008) · low 41 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GEX

90in 2025

2007: 79 days median2008: 86 days median2009: 100 days median2010: 96 days median2011: 83 days median2012: 118 days median2013: 144 days median2014: 147 days median2015: 112 days median2016: 114 days median2017: 90 days median2018: 78 days median2019: 88 days median2020: 90 days median2021: 123 days median2022: 152 days median2023: 87 days median2024: 90 days median2025: 90 days median2026 (partial year): 90 days median
2007high 152 (2022) · low 78 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GEX

3in 2024

2007: 92008: 22010: 42011: 182012: 52013: 32014: 62016: 12017: 5, 1 Class I2018: 52019: 62020: 12023: 62024: 32026 (partial year): 2
2007high 18 (2011) · low 0 (2009)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · GEX

2,720in 2025

2007: 3422008: 2322009: 2092010: 1,7112011: 3,0242012: 2,0002013: 2,2362014: 2,0362015: 2,0992016: 2,5852017: 2,9772018: 3,5252019: 2,7092020: 2,1832021: 3,4652022: 2,2882023: 2,3372024: 2,1872025: 2,720
2007high 3,525 (2018) · low 209 (2009)2025

MAUDE reports naming product code GEX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200773799342
2008107862232
2009691000209
2010509641,711
20114183183,024
20124511852,000
20134614432,236
20146114762,036
20154711202,099
20165111412,585
201767905 (1)2,977
2018517853,525
2019418862,709
2020529012,183
20215312303,465
20226015202,288
2023528762,337
2024829032,187
2025839002,720
202657902—

What is it indicated for?

The DuraLite-GL Is a mplacement fiber optic component for the Candela GeirnleLASE family of lasers.

The DuraLltsGL may be used as a replacement part for all procedures as cleared by the FDA for the Candela GentleLase family of lasers.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K041262: Duralite-GL.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K041262

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026