510(k) · Cleared
ClearedFlexi-Stat Disposable Adhesive SPO2 Sensors
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Elekon Industries U.S.A., Inc. · DQA Oximeter
Cleared on Sep 14, 2004 as substantially equivalent to K991823 (Nellcor Puritan Bennett, Inc., 1999) and 3 other predicates after a 99-day review. Its family tree reaches back 4 generations to 1997. 2 later devices descend from it.
- Decided
- Sep 14, 2004
- Review
- 99 days
- Class
- Class II
- Product code
- DQA
- Recalls
- None
- Predicates
- 5
Its longest line of descent runs back 4 generations to K962603 (1997). 8 ancestors in all, the oldest K955642 (1996). 2 later devices descend from it, 2 citing it directly.
- Root · 4 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
- 3 generations backK973887 Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and…Masimo Corp. · 1998
- 2 generations backK982255 Model 2000 Pulse OximeterIvy Biomedical Systems, Inc. · 1998
- 1 generation backK991823 N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc. · 1999
- This deviceK041522 Flexi-Stat Disposable Adhesive SPO2 SensorsElekon Industries U.S.A., Inc. · 2004
- Descendant · cites it directly · 1 of its ownK042705 Disposable Non-Adhesive SPO2 SensorsElekon Industries U.S.A., Inc. · 2004
- Descendant · cites it directly · 0 of its ownK061191 Finger and Ear Sensors and Neonatal-Adult and Adult/Pediatric…Measurement Specialties, Inc. · 2006
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K962603 | Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables | Masimo Corp. | 1997 | — |
| −3 | K973887 | Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables | Masimo Corp. | 1998 | — |
| −2 | K982255 | Model 2000 Pulse Oximeter | Ivy Biomedical Systems, Inc. | 1998 | — |
| −1 | K991823 | N-395 Pulse Oximeter, Model N-395 | Nellcor Puritan Bennett, Inc. | 1999 | — |
| 0 (this device) | K041522 | Flexi-Stat Disposable Adhesive SPO2 Sensors | Elekon Industries U.S.A., Inc. | 2004 | — |
| +1 | K042705 | Disposable Non-Adhesive SPO2 Sensors | Elekon Industries U.S.A., Inc. | 2004 | — |
| +1 | K061191 | Finger and Ear Sensors and Neonatal-Adult and Adult/Pediatric Adhesive Sensors… | Measurement Specialties, Inc. | 2006 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1996 | 2 | 0 |
| 1998 | 1 | 0 |
| 2000 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2004 | 1 | 0 |
| 2006 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DQA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DQA device
- #1 K221282 Empatica Health Monitoring Platformscore 20.1 · 38 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (5)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.
| Type | Number | Device | Decided |
|---|---|---|---|
| Kept off the family tree | K86378 | Nellcor, BCI, and Datex pulse oximeter sensors Number could not be read Summary page 1…Stat SpO2 Sensors Predicate Device: Elekon Flexi-StatTM sensors are substantially equivalent to Nellcor, BCI, and Datex pulse oximeter sensors marketed under 510(k) ft K86378, K991823, K962156, and K983684. These sensors are also equivalent to Envitec's after-market sensors marketed under 5 10O(k) Ii K9… | |
| * | K991823 | N-395 Pulse Oximeter, Model N-395Summary page 1…2 Sensors Predicate Device: Elekon Flexi-StatTM sensors are substantially equivalent to Nellcor, BCI, and Datex pulse oximeter sensors marketed under 510(k) ft K86378, K991823, K962156, and K983684. These sensors are also equivalent to Envitec's after-market sensors marketed under 5 10O(k) Ii K992215.… | 1999 |
| * | K962156 | 3304 Pulse OximeterSummary page 1…Predicate Device: Elekon Flexi-StatTM sensors are substantially equivalent to Nellcor, BCI, and Datex pulse oximeter sensors marketed under 510(k) ft K86378, K991823, K962156, and K983684. These sensors are also equivalent to Envitec's after-market sensors marketed under 5 10O(k) Ii K992215. Descripti… | 1996 |
| * | K983684 | Datex-Ohmeda 3800+/3800P+ or 3900/3900P Pulse OximetersSummary page 1…Device: Elekon Flexi-StatTM sensors are substantially equivalent to Nellcor, BCI, and Datex pulse oximeter sensors marketed under 510(k) ft K86378, K991823, K962156, and K983684. These sensors are also equivalent to Envitec's after-market sensors marketed under 5 10O(k) Ii K992215. Description: The Flex… | 1998 |
| * | K992215 | Multicompatible Envitec Finger Clip Sensor, Multicompatible Envitec Adult Disposable…Summary page 1…er sensors marketed under 510(k) ft K86378, K991823, K962156, and K983684. These sensors are also equivalent to Envitec's after-market sensors marketed under 5 10O(k) Ii K992215. Description: The Flexi-Stat(tm) SPO2 Sensor is an electro-optical sensor that functions without skin penetration, electrical… | 2000 |
What descends from it? (2)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 7 years and passes through 4 companies; a new generation was cleared every 11 months on median.
- None of the 8 ancestors has a recall.
- Of its descendants, K042705 (Elekon Industries U.S.A., Inc., 2004) has gone furthest, with 1 descendant of its own.
- 20 other devices also cite its predicate K991823.
How does its category compare?
All DQA devicesDQA Oximeter: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DQA
15in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DQA
182in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DQA
3in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DQA
399in 2025
MAUDE reports naming product code DQA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 20 | 122 | 6 | 325 |
| 2008 | 22 | 97 | 5 | 312 |
| 2009 | 35 | 117 | 29 | 281 |
| 2010 | 29 | 127 | 4 | 185 |
| 2011 | 15 | 195 | 1 | 164 |
| 2012 | 14 | 120 | 0 | 322 |
| 2013 | 15 | 182 | 0 | 468 |
| 2014 | 11 | 175 | 2 | 1,124 |
| 2015 | 13 | 158 | 1 | 2,082 |
| 2016 | 14 | 246 | 0 | 1,775 |
| 2017 | 9 | 200 | 0 | 1,190 |
| 2018 | 18 | 260 | 32 | 694 |
| 2019 | 19 | 158 | 0 | 548 |
| 2020 | 15 | 126 | 0 | 426 |
| 2021 | 10 | 174 | 0 | 553 |
| 2022 | 20 | 265 | 0 | 478 |
| 2023 | 13 | 317 | 0 | 392 |
| 2024 | 14 | 285 | 3 | 545 |
| 2025 | 15 | 182 | 0 | 399 |
| 2026 | 8 | 187 | 0 | — |
What is it indicated for?
The Flexi-Stat SpO₂ Sensor is indicated for continuous, non-invasive functional arterial oxygen saturation and pulse rate monitoring in patients Weighing > 30 kg.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K041522 · printed Nov 5, 2026
Cite this page
510(k) Report. “K041522: Flexi-Stat Disposable Adhesive SPO2 Sensors.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K041522
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026