510(k) · Cleared
Recalled · Class II · 2025H&S-Conductivity Standard Solution
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
H & S Technical Services · FKH Solution-Test Standard-Conductivity, Dialysis
Cleared on Jul 2, 2004 as substantially equivalent to K032075 (Ibp Instruments GmbH, 2003) after a 15-day review. Its family tree reaches back 2 generations to 1985. It has been recalled once.
- Decided
- Jul 2, 2004
- Review
- 15 days
- Class
- Class II
- Product code
- FKH
- Recalls
- 1
- Predicates
- 2
Its longest line of descent runs back 2 generations to K851362 (1985). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FKH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K032075 | Conductivity Standard Solution-Metercare Our OCR of the scanned summary read K032073, FDA’s number for Gore Introducer Sheath with Silicone Pinch Valve (W. L. Gore & Associates, Inc.). Corrected to the number one digit away whose FDA name carries the summary’s words for the device, “Conductivity Standard Solution - MeterCare”. | 2003 |
| Kept off the family tree | K043330 | FDA’s K043330 is Polypropilene Surgical Sutures Not matched in our reading of the summary (scans can blur digits), so it is kept off the family tree | 2005 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Dec 12, 2025 | Class II | Z-1185-2026 | Under Investigation by firm | due to a defect associated with the conductivity values of the solution used to calibrate meters and result in the reporting of incorrect conductivity values for dialysate. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 19 years and passes through 3 companies; a new generation was cleared every 18.3 years on median.
- None of the 2 ancestors has a recall.
How does its category compare?
All FKH devicesFKH Solution-Test Standard-Conductivity, Dialysis: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FKH
1in 2019
2026 to Oct 25, outlined.
Median 510(k) review, days · FKH
Too few FKH 510(k)s in any year since 2007 to give a median.
Recalls per year · FKH
No recall names FKH since 2007.
Adverse event reports per year · FKH
2in 2013
MAUDE reports naming product code FKH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 1 | — | 0 | 2 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 1 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
"H&S - Conductivity Standard Solutions" are a secondary standard solution used for the calibration of conductivity cells together with conductivity meters; which may include meters and cells used by the hemodialysis technician to verify or calibrate conductivity functions of dialysis related equipment.
These solutions are used remotely from the hemodialysis machine or water purification equipment and do not come in contact with the patient.
Conductivity Standard Solution is for In-Vitro Use Only.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K041636 · printed Nov 6, 2026
Cite this page
510(k) Report. “K041636: H&S-Conductivity Standard Solution.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K041636
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026