510(k) · Cleared
ClearedTrio Monitor
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Datascope Corp. · MWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)
Cleared on Jul 23, 2004 as substantially equivalent to K032338 (Datascope Corp., 2004) and 1 other predicate after an 8-day review. Its family tree reaches back 4 generations to 1994.
- Decided
- Jul 23, 2004
- Review
- 8 days
- Class
- Class II
- Product code
- MWI
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 4 generations to K933143 (1994). 25 ancestors in all, the oldest K842616 (1984). No later device cites it as a predicate yet.
- Root · 4 generations backK933143 Model Eli 300 ElectrocardiographMortara Instrument, Inc. · 1994
- 3 generations backK962970 Spacelabs Medical 12-Lead Diagnostic Ecg Analysis OptionSpacelabs Medical, Inc. · 1997
- 2 generations backK972502 Spacelabs Medical Integrated Multiparameter Module 90496Spacelabs Medical, Inc. · 1998 · Recalled
- 1 generation backK993531 Passport 2 Vital Signs Monitor, Model 0998-00-0170-XXDatascope Corp. · 2000 · Recalled
- This deviceK041907 Trio MonitorDatascope Corp. · 2004
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K933143 | Model Eli 300 Electrocardiograph | Mortara Instrument, Inc. | 1994 | — |
| −3 | K962970 | Spacelabs Medical 12-Lead Diagnostic Ecg Analysis Option | Spacelabs Medical, Inc. | 1997 | — |
| −2 | K972502 | Spacelabs Medical Integrated Multiparameter Module 90496 | Spacelabs Medical, Inc. | 1998 | 3 |
| −1 | K993531 | Passport 2 Vital Signs Monitor, Model 0998-00-0170-XX | Datascope Corp. | 2000 | 1 |
| 0 (this device) | K041907 | Trio Monitor | Datascope Corp. | 2004 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1984 | 1 | 0 |
| 1989 | 1 | 0 |
| 1990 | 2 | 0 |
| 1991 | 2 | 0 |
| 1993 | 1 | 0 |
| 1994 | 3 | 0 |
| 1995 | 3 | 0 |
| 1996 | 3 | 0 |
| 1997 | 2 | 0 |
| 1998 | 1 | 0 |
| 1999 | 1 | 0 |
| 2004 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MWI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MWI device
- #1 K230457 Empatica Health Monitoring Platform…score 28.0 · 39 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K032338 | Trio Monitor Model 0998-00-0600Summary page 1…870.2340 Electrocardiograph 21 CFR 870.2700 Oximeter 21 CFR 880.2910 Clinical electronic thermometers Predicate Device: Datascope Trio Monitor, 510(k) K032338 (FDA determination of substantial equivalence, February 11, 2004) Datascope Passport 2,… | 2004 |
| * | K993531 | Passport 2 Vital Signs Monitor, Model 0998-00-0170-XXSummary page 1…ope Trio Monitor, 510(k) K032338 (FDA determination of substantial equivalence, February 11, 2004) Datascope Passport 2, 510(k) K993531 (FDA determination of substantial equivalence, January 13, 2000) Device Description: Mindray Bio-Medical C… | 2000 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 10 years and passes through 3 companies; a new generation was cleared every 2.9 years on median.
- 6 of the 25 ancestors have a recall of any class.
How does its category compare?
All MWI devicesMWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MWI
4in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MWI
247in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MWI
9so far in 2026, the most since 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MWI
182in 2025
MAUDE reports naming product code MWI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 9 | 42 | 1 | 3 |
| 2008 | 9 | 49 | 1 | 3 |
| 2009 | 6 | 112 | 2 | 20 |
| 2010 | 17 | 58 | 2 | 17 |
| 2011 | 11 | 78 | 3 | 16 |
| 2012 | 13 | 104 | 5 | 31 |
| 2013 | 20 | 85 | 3 | 42 |
| 2014 | 16 | 148 | 6 | 30 |
| 2015 | 19 | 127 | 1 | 31 |
| 2016 | 12 | 165 | 0 | 51 |
| 2017 | 13 | 205 | 2 | 85 |
| 2018 | 11 | 217 | 0 | 158 |
| 2019 | 14 | 255 | 4 | 169 |
| 2020 | 8 | 138 | 0 | 110 |
| 2021 | 9 | 161 | 0 | 188 |
| 2022 | 5 | 231 | 2 | 168 |
| 2023 | 8 | 250 | 0 | 179 |
| 2024 | 10 | 202 | 5 | 120 |
| 2025 | 4 | 247 | 0 | 182 |
| 2026 | 6 | 239 | 9 | — |
What is it indicated for?
The Trio TM monitor is intended for use in healthcare settings under the direct supervision of a licensed healthcare practitioner. The intended use of the monitor is to monitor physiologic parameter data on adult and pediatric patients. Physiologic data includes: electrocardiogram, invasive blood pressure, non-invasive blood pressure (NIBP), pulse oximetry, heart rate (derived from ECG, SpO2 or NIBP), respiration and temperature as summarized in the…
Read the full statement (107 words)
The Trio TM monitor is intended for use in healthcare settings under the direct supervision of a licensed healthcare practitioner. The intended use of the monitor is to monitor physiologic parameter data on adult and pediatric patients. Physiologic data includes: electrocardiogram, invasive blood pressure, non-invasive blood pressure (NIBP), pulse oximetry, heart rate (derived from ECG, SpO2 or NIBP), respiration and temperature as summarized in the operating instructions manual. The information can be displayed, stored, trended and printed.
The monitor is not intended for home use. The monitor is not intended to be an apnea monitor. It was not designed or validated for use as an apnea monitor
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K041907 · printed Nov 5, 2026
Cite this page
510(k) Report. “K041907: Trio Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K041907
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026