510(k) Report

510(k) · Cleared

Cleared

Sintea Biotech Anterior Plate System, Model Acp.XX.T5.X

K041989510(k) TraditionalCleared Sep 16, 200455-day reviewClass II21 CFR 888.3060

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sintea Biotech, Inc. · KWQ Appliance, Fixation, Spinal Intervertebral Body

Cleared on Sep 16, 2004 as substantially equivalent to K000742 (Synthes Spine, 2000) and 1 other predicate after a 55-day review. Its family tree reaches back 1 generation to 2000. 1 later device descends from it.

Decided
Sep 16, 2004
Review
55 days
Class
Class II
Product code
KWQ
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K000536 (2000). 2 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2000: 1 other ancestor2012: 1 descendant clearedK000536 · Synthes Anterior CSLP System · Synthes Spine · 2000 · recalled200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 1 descendant K000536 · Synthes Anterior CSLP System · Synthes Spine · 2000 · recalled0
  1. Root · 1 generation backK000536 Synthes Anterior CSLP SystemSynthes Spine · 2000 · Recalled
  2. This deviceK041989 Sintea Biotech Anterior Plate System, Model Acp.XX.T5.XSintea Biotech, Inc. · 2004
  3. Descendant · cites it directly · 0 of its ownK112861 Sintea Plustek Anterior Cervical Plate SystemSintea Plustek, LLC · 2012

Most influential descendants

Showing 1 of 1 · See all
  • K112861Sintea Plustek Anterior Cervical Plate SystemSintea Plustek, LLC · 2012 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K000536Synthes Anterior CSLP SystemSynthes Spine20001
0 (this device)K041989Sintea Biotech Anterior Plate System, Model Acp.XX.T5.XSintea Biotech, Inc.2004—
+1K112861Sintea Plustek Anterior Cervical Plate SystemSintea Plustek, LLC2012—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201210
FIG. 1 — Lineage of K041989, 2000–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KWQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KWQ device

  1. #1 K233640 Segmental Plating System (SPS);IdentiTi SPS…score 21.9 · 31 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K000742Synthes Anterior CSLP System
Summary page 2
…System is substantially equivalent to Synthes' Cervical Spine Locking Plate (CSLP), K000742 and K000536, (Decision Dates: 03/29/2000 and 03/15/2000, respectively). A basic feature comparison table for the Sintea Biotech A…
Synthes Spine2000—
*K000536Synthes Anterior CSLP System
Summary page 2
…is substantially equivalent to Synthes' Cervical Spine Locking Plate (CSLP), K000742 and K000536, (Decision Dates: 03/29/2000 and 03/15/2000, respectively). A basic feature comparison table for the Sintea Biotech Anterior Cerv…
Synthes Spine20001

Also cleared against K000742: 15 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K112861Sintea Plustek Anterior Cervical Plate SystemSintea Plustek, LLC20120

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 1 of the 2 ancestors has a recall of any class.
  • Of its descendants, K112861 (Sintea Plustek, LLC, 2012) has gone furthest, with 0 descendants of its own.
  • 15 other devices also cite its predicate K000742.

How does its category compare?

All KWQ devices

KWQ Appliance, Fixation, Spinal Intervertebral Body: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KWQ

7in 2025

2007: 272008: 322009: 232010: 232011: 222012: 262013: 222014: 172015: 252016: 152017: 202018: 222019: 262020: 262021: 172022: 182023: 162024: 172025: 72026 (partial year): 10
2007high 32 (2008) · low 7 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KWQ

64in 2025

2007: 101 days median2008: 70 days median2009: 90 days median2010: 104 days median2011: 95 days median2012: 90 days median2013: 88 days median2014: 124 days median2015: 102 days median2016: 121 days median2017: 67 days median2018: 95 days median2019: 81 days median2020: 55 days median2021: 59 days median2022: 85 days median2023: 59 days median2024: 64 days median2025: 64 days median2026 (partial year): 76 days median
2007high 124 (2014) · low 55 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KWQ

1in 2018

2007: 22008: 332009: 352010: 22011: 52012: 72013: 62015: 22016: 92017: 82018: 1
2007high 35 (2009) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KWQ

248in 2025

2007: 2882008: 3482009: 3552010: 6912011: 4152012: 5442013: 7962014: 5462015: 5622016: 5022017: 4922018: 3412019: 2982020: 4002021: 5912022: 3922023: 3202024: 4192025: 248
2007high 796 (2013) · low 248 (2025)2025

MAUDE reports naming product code KWQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007271012288
2008327033348
2009239035355
2010231042691
201122955415
201226907544
201322886796
2014171240546
2015251022562
2016151219502
201720678492
201822951341
201926810298
202026550400
202117590591
202218850392
202316590320
202417640419
20257640248
202610760—

What is it indicated for?

The Sintea Biotech Anterior Cervical Plate System is indicated for use in the cervical spine (levels C3 to C7) in the following conditions:

* Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies)

* Spondylolisthesis

* Trauma (fracture or dislocation)

* Spinal stenosis

* Deformities or curvature (scoliosis, kyphosis, lordosis)

* Tumor

* Pseudarthrosis

* Failed previous fusion

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K041989: Sintea Biotech Anterior Plate System, Model Acp.XX.T5.X.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K041989

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026