Flowmedic (Israel), Ltd. · JOW Sleeve, Limb, Compressible
Cleared on Jan 12, 2005 as substantially equivalent to K024019 (Aircast, Inc., 2003) and 2 other predicates after a 149-day review. Its family tree reaches back 1 generation to 1996.
- Decided
- Jan 12, 2005
- Review
- 149 days
- Class
- Class II
- Product code
- JOW
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 1 generation to K942530 (1996). 3 ancestors in all. No later device cites it as a predicate yet.
- Root · 1 generation backK942530 Art-Assist Model AA-1000Aci Medical, Inc. · 1996
- This deviceK042217 Flowmedic, Model 220Flowmedic (Israel), Ltd. · 2005
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K942530 | Art-Assist Model AA-1000 | Aci Medical, Inc. | 1996 | — |
| 0 (this device) | K042217 | Flowmedic, Model 220 | Flowmedic (Israel), Ltd. | 2005 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2002 | 1 | 0 |
| 2003 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JOW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JOW device
- #1 K253555 Flexitouch® Plus Advanced Pneumatic…score 14.8 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K024019 | Arterialflow System, Model 32ASummary page 3…Cardiovascular 7-4 Predicate Devices: • The ArterialFlowTM System (Aircast, Inc), cleared under K024019 * The ArtAssist® Model AA-1000 (ACI Medical, Inc.), cleared under K942530 * WizAir DVTTM (Medical Comp… | 2003 |
| * | K942530 | Art-Assist Model AA-1000Summary page 3…• The ArterialFlowTM System (Aircast, Inc), cleared under K024019 * The ArtAssist® Model AA-1000 (ACI Medical, Inc.), cleared under K942530 * WizAir DVTTM (Medical Compression Systems (DBN) Ltd.), cleared under K012994 Performance Standards:… | 1996 |
| * | K012994 | Wizair DVTSummary page 3…ArtAssist® Model AA-1000 (ACI Medical, Inc.), cleared under K942530 * WizAir DVTTM (Medical Compression Systems (DBN) Ltd.), cleared under K012994 Performance Standards: No performance standards have been established for such device under Section 514 of the Feder… | 2002 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- None of the 3 ancestors has a recall.
How does its category compare?
All JOW devicesJOW Sleeve, Limb, Compressible: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JOW
7in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JOW
168in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JOW
1in 2019
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JOW
24in 2025
MAUDE reports naming product code JOW, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 6 | 66 | 0 | 12 |
| 2008 | 4 | 112 | 7 | 36 |
| 2009 | 3 | 84 | 0 | 45 |
| 2010 | 18 | 71 | 2 | 66 |
| 2011 | 11 | 104 | 3 | 50 |
| 2012 | 13 | 63 | 2 | 100 |
| 2013 | 17 | 94 | 0 | 169 |
| 2014 | 16 | 91 | 0 | 93 |
| 2015 | 10 | 160 | 0 | 137 |
| 2016 | 9 | 121 | 0 | 150 |
| 2017 | 9 | 116 | 1 | 149 |
| 2018 | 11 | 136 | 0 | 114 |
| 2019 | 11 | 88 | 1 | 102 |
| 2020 | 14 | 158 | 0 | 50 |
| 2021 | 16 | 132 | 0 | 34 |
| 2022 | 7 | 80 | 0 | 27 |
| 2023 | 6 | 160 | 0 | 57 |
| 2024 | 8 | 197 | 0 | 30 |
| 2025 | 7 | 168 | 0 | 24 |
| 2026 | 6 | 252 | 0 | — |
What is it indicated for?
The FlowMedicTM FM220 System is intended for the improvement of blood circulation in the lower extremities to help prevent and reduce complications of poor circulation.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K042217 · printed Nov 6, 2026
Cite this page
510(k) Report. “K042217: Flowmedic, Model 220.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K042217
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026