510(k) Report

510(k) · Cleared

Cleared

Ossaplast Ortho, O.5ML, Model# 221 900, Ossaplast Ortho, 1.0ML, Model# 221 901, Ossaplast Ortho, 3.0ML, Model# 221 903

K042305510(k) AbbreviatedCleared Oct 21, 200457-day reviewClass II21 CFR 888.3045

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ossacur AG · MQV Filler, Bone Void, Calcium Compound

Cleared on Oct 21, 2004 as substantially equivalent to K014156 (Curasan AG, 2002) after a 57-day review. Its family tree reaches back 1 generation to 2002. 2 later devices descend from it.

Decided
Oct 21, 2004
Review
57 days
Class
Class II
Product code
MQV
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K014156 (2002). 2 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2005: 1 descendant cleared2006: 1 descendant clearedK014156 · Cerasorb Ortho · Curasan AG · 2002200020052010201520202025
Descendants, by generation 1 generation forward: 2 descendants K014156 · Cerasorb Ortho · Curasan AG · 20020
  1. Root · 1 generation backK014156 Cerasorb OrthoCurasan AG · 2002
  2. This deviceK042305 Ossaplast Ortho, O.5ML, Model# 221 900, Ossaplast Ortho, 1.0ML…Ossacur AG · 2004
  3. Descendant · cites it directly · 1 of its ownK050416 Ossaplast OrthoOssacur AG · 2005
  4. Descendant · cites it directly · 0 of its ownK051047 Colloss E Bone Void FillerOssacur AG · 2006

Most influential descendants

Showing 2 of 2 · See all
  • K050416Ossaplast OrthoOssacur AG · 2005 · cites it directly1descendant
  • K051047Colloss E Bone Void FillerOssacur AG · 2006 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K014156Cerasorb OrthoCurasan AG2002—
0 (this device)K042305Ossaplast Ortho, O.5ML, Model# 221 900, Ossaplast Ortho, 1.0ML, Model# 221…Ossacur AG2004—
+1K050416Ossaplast OrthoOssacur AG2005—
+1K051047Colloss E Bone Void FillerOssacur AG2006—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200510
200610
FIG. 1 — Lineage of K042305, 2002–2006Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQV? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQV device

  1. #1 K232315 Catalyst Bone Void Fillerscore 25.2 · 25 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K014156Cerasorb Ortho
Summary page 1
…d filler device, §888.3045 (Product Code: MOV) C. Predicate Device Trade Name: Cerasorb® ORTIHO (K0141 56) D. Device Description OSSAPLAST ORTHO is a synthetic, implantable, resorbable, radiopaque f3-trical…
Curasan AG2002—

Also cleared against K014156: 7 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K050416Ossaplast OrthoOssacur AG20051
K051047Colloss E Bone Void FillerOssacur AG20060

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K050416 (Ossacur AG, 2005) has gone furthest, with 1 descendant of its own.
  • 7 other devices also cite its predicate K014156.

How does its category compare?

All MQV devices

MQV Filler, Bone Void, Calcium Compound: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MQV

14in 2025

2007: 352008: 322009: 232010: 172011: 162012: 92013: 122014: 202015: 182016: 82017: 172018: 232019: 132020: 152021: 82022: 92023: 212024: 282025: 142026 (partial year): 5
2007high 35 (2007) · low 8 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQV

57in 2025

2007: 144 days median2008: 102 days median2009: 180 days median2010: 147 days median2011: 92 days median2012: 107 days median2013: 197 days median2014: 153 days median2015: 184 days median2016: 214 days median2017: 124 days median2018: 124 days median2019: 90 days median2020: 132 days median2021: 88 days median2022: 118 days median2023: 74 days median2024: 55 days median2025: 57 days median2026 (partial year): 96 days median
2007high 214 (2016) · low 55 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQV

1in 2025

2007: 52008: 32009: 12011: 62012: 32013: 22016: 12017: 12018: 22020: 12023: 32024: 22025: 12026 (partial year): 4
2007high 6 (2011) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQV

57in 2025

2007: 672008: 712009: 812010: 682011: 1142012: 1492013: 2232014: 1112015: 1252016: 1062017: 1072018: 862019: 652020: 1262021: 1012022: 472023: 1202024: 682025: 57
2007high 223 (2013) · low 47 (2022)2025

MAUDE reports naming product code MQV, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735144567
200832102371
200923180181
201017147068
201116926114
201291073149
2013121972223
2014201530111
2015181840125
201682141106
2017171241107
201823124286
20191390065
2020151321126
20218880101
20229118047
202321743120
20242855268
20251457157
20265964—

What is it indicated for?

OSSAPLAST ORTHO is intended for use in filling bony voids or gaps of the skeletal system (e.g., the spine, pelvis, ilium, and/or extremities) that are not intrinsic to the stability of the bony structure. These defects may be surgically created osseous defects or osseous defects resulting from traumatic injury to the bone or a degenerative process. OSSAPLAST ORTHO is gradually resorbed and replaced with bone during the healing process.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K042305: Ossaplast Ortho, O.5ML, Model# 221 900, Ossaplast Ortho, 1.0ML, Model# 221 901, Ossaplast Ortho, 3.0ML, Model# 221 903.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K042305

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026