510(k) · Cleared
ClearedMeter Trax Trilevel, Low Level, Mid Level, High Level Trilevel Minipak
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Bio-Rad Laboratories, Inc. · JPK Mixture, Hematology Quality Control
Cleared on Oct 14, 2004 as substantially equivalent to K904461 (Hematronix, Inc., 1990) after a 45-day review. Its family tree reaches back 1 generation to 1990.
- Decided
- Oct 14, 2004
- Review
- 45 days
- Class
- Class II
- Product code
- JPK
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K904461 (1990). No later device cites it as a predicate yet.
- Root · 1 generation backK904461 Meter TraxHematronix, Inc. · 1990
- This deviceK042336 Meter Trax Trilevel, Low Level, Mid Level, High Level Trilevel MinipakBio-Rad Laboratories, Inc. · 2004
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K904461 | Meter Trax | Hematronix, Inc. | 1990 | — |
| 0 (this device) | K042336 | Meter Trax Trilevel, Low Level, Mid Level, High Level Trilevel Minipak | Bio-Rad Laboratories, Inc. | 2004 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JPK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K904461 | Meter TraxSummary page 2…age 2 of 2 Meter Trax TM Control 5.0 Comparison of the new device with the Predicate Device Meter Trax Control it substantial equivalent to Meter Trax (K904461) currently in commercial distribution The similarities and differences are listed below. Table 1. Similariti… | 1990 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Its one ancestor has no recall.
How does its category compare?
All JPK devicesJPK Mixture, Hematology Quality Control: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JPK
4in 2016
2026 to Oct 25, outlined.
Median 510(k) review, days · JPK
296in 2016
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JPK
1in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JPK
2in 2023
MAUDE reports naming product code JPK, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 5 | 44 | 1 | 14 |
| 2008 | 0 | — | 0 | 1 |
| 2009 | 5 | 187 | 0 | 0 |
| 2010 | 4 | 267 | 2 | 5 |
| 2011 | 1 | — | 3 | 56 |
| 2012 | 2 | — | 1 | 2 |
| 2013 | 1 | — | 0 | 0 |
| 2014 | 2 | — | 0 | 1 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 4 | 296 | 0 | 0 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 1 |
| 2020 | 0 | — | 1 | 1 |
| 2021 | 0 | — | 2 | 1 |
| 2022 | 0 | — | 1 | 0 |
| 2023 | 0 | — | 0 | 2 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
Meter Trax is an assayed whole blood control used in monitoring the precision of laboratory testing procedures for the analytes listed in this package insert.
The following parameters are listed in the package insert:
* Glucose
* Hemoglobin
* Hematoait
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K042336 · printed Nov 6, 2026
Cite this page
510(k) Report. “K042336: Meter Trax Trilevel, Low Level, Mid Level, High Level Trilevel Minipak.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K042336
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026