# K042476: Vitros Chemistry Products Valp Reagent; Vitro Chemistry Products Calibrator Kit 12; Vitros Chemistry Products TDM Perfos

- Pathway: 510(k) (Traditional)
- Applicant: Ortho-Clinical Diagnostics, Inc.
- Decided: Dec 1, 2004 after 79 days
- Product code: LEG (Enzyme Immunoassay, Valproic Acid)
- Device class: 2
- Regulation: 21 CFR 862.3645
- Recalls of this device: 3 (0 Class I)
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 1 generation back to K984288 (1999). 2 ancestors in all.
3 later devices descend from it; 3 cite it directly.
0 of 6 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K002551: Emit 2000 Valproic Acid Assay, Emit 2000 Valproic Acid Calibrators, Model 4G019UL, 4G109UL, Dade Behring, Inc. (2000) Summary page 3.
- K984288: Vitros Chemistry Products PHBR Slides, Ortho-Clinical Diagnostics, Inc. (1999) Summary page 3.

## Most influential descendants
- K043384: Vitros Chemistry Products Tobra Reagent, Calibrator Kit 14 and TDM Performance Verifiers I, II and Iii (2005), 0 descendants of its own
- K043386: Vitros Chemistry Products Vanc Reagent, Calibrator Kit 11 and TDM Performance Verifiers I, II and Iii (2005), 0 descendants of its own
- K042479: Vitros Chemistry Products Gent, Tobra & Vanc Reagents; Vitros Chemistyr Products Calibrator Kits 11, 13 & 14; Vitros Che (2005), 0 descendants of its own

## Recalls of this device
- Dec 11, 2018 · Class II · Z-0848-2019: Negative bias results when using VITROS VALP Reagent, GEN 25.
- May 10, 2011 · Not classified · Z-0984-2012: Results using VITROS Chemistry Products VALP Reagent were negatively biased compared to other manufacturers. OCD confirmed that patient results were also affected by this issue.
- Apr 18, 2005 · Not classified · Z-0866-05: Negatively biased results may be observed when the reagent is stored on the VITROS 5,1FS Chemistry System for less than seven days.

## Indications for use
For in vitro diagnostic use only. VITROS Chemistry Products VALP Reagent is used on the VITROS 5,1 FS Chemistry System to quantitatively measure valproic acid (VALP) concentration in human serum and plasma. Serum or plasma valproic acid measurements are used in the diagnosis and treatment of valproic acid overdose and in monitoring levels of valproic acid to ensure appropriate therapy. For in vitro diagnostic use only. VITROS Chemistry Products Calibrator Kit 12 is used to calibrate VITROS 5,1 FS Chemistry Systems for the quantitative measurement of valproic acid (VALP). For in vitro diagnostic use only. VITROS TDM Performance Verifier is an assayed control used to monitor performance of ACET, CRBM, DGXN, PHBR, PHYT and VALP on VITROS Chemistry Systems.