Omron Healthcare, Inc. · DXN System, Measurement, Blood-Pressure, Non-Invasive
Cleared on Apr 5, 2005 after a 202-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 49 later devices descend from it.
- Decided
- Apr 5, 2005
- Review
- 202 days
- Class
- Class II
- Product code
- DXN
- Recalls
- None
- Predicates
- 0
49 later devices descend from it, 7 citing it directly.
- This deviceK042505 Omron Digital Wrist Blood Pressure Monitor, Model Hem-609NOmron Healthcare, Inc. · 2005
- Descendant · cites it directly · 21 of its ownK123498 BP652N (Hem-6300-Z)Omron Healthcare, Inc. · 2013
- Descendant · 2 generations on · 19 of its ownK142917 BP652N (Hem-6300-Z)Omron Healthcare, Inc. · 2014
- Descendant · cites it directly · 15 of its ownK131742 HEM-6131Omron Healthcare, Inc. · 2013
- Descendant · 2 generations on · 11 of its ownK182127 Wrist Blood Pressure Monitor Model BP6100Omron Healthcare, Inc. · 2018
- Descendant · 3 generations on · 10 of its ownK182166 Wrist Blood Pressure Monitor Model BP4350Omron Healthcare, Inc. · 2018
Showing 5 of 49 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 49 · See all- K123498BP652N (Hem-6300-Z)Omron Healthcare, Inc. · 2013 · cites it directly21descendants
- K142917BP652N (Hem-6300-Z)Omron Healthcare, Inc. · 2014 · 2 generations on19descendants
- K131742HEM-6131Omron Healthcare, Inc. · 2013 · cites it directly15descendants
- K182127Wrist Blood Pressure Monitor Model BP6100Omron Healthcare, Inc. · 2018 · 2 generations on11descendants
- K182166Wrist Blood Pressure Monitor Model BP4350Omron Healthcare, Inc. · 2018 · 3 generations on10descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K042505 | Omron Digital Wrist Blood Pressure Monitor, Model Hem-609N | Omron Healthcare, Inc. | 2005 | — |
| +1 | K123498 | BP652N (Hem-6300-Z) | Omron Healthcare, Inc. | 2013 | — |
| +2 | K142917 | BP652N (Hem-6300-Z) | Omron Healthcare, Inc. | 2014 | — |
| +1 | K131742 | HEM-6131 | Omron Healthcare, Inc. | 2013 | — |
| +2 | K182127 | Wrist Blood Pressure Monitor Model BP6100 | Omron Healthcare, Inc. | 2018 | — |
| +3 | K182166 | Wrist Blood Pressure Monitor Model BP4350 | Omron Healthcare, Inc. | 2018 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2008 | 1 | 0 |
| 2009 | 1 | 0 |
| 2012 | 5 | 0 |
| 2013 | 3 | 0 |
| 2014 | 3 | 0 |
| 2015 | 2 | 0 |
| 2016 | 3 | 0 |
| 2017 | 1 | 0 |
| 2018 | 4 | 0 |
| 2019 | 2 | 0 |
| 2020 | 2 | 0 |
| 2021 | 2 | 0 |
| 2022 | 3 | 0 |
| 2023 | 6 | 0 |
| 2025 | 4 | 0 |
| 2026 | 7 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DXN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DXN device
- #1 K222125 Arm Blood Pressure Monitor, models AOJ-30A…score 18.5 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it? (49)
See all 497 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K123498 | BP652N (Hem-6300-Z) | 2013 | 21 |
| K131742 | HEM-6131 | 2013 | 15 |
| K122482 | Transtek Wrist Blood Pressure Monitor | 2012 | 5 |
| K083043 | King`Yield Wrist Blood Pressure Monitor, Model BP201 | 2008 | 5 |
| K120430 | Microlife Wrist Watch Blood Preeure Monitor, BP3MO1-3P | 2012 | 4 |
| K092163 | Full Automatic (Nibp) Blood Pressure Monitor, Model HL168KB | 2009 | 1 |
| K131749 | HEM-6221 | 2013 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K123498 (Omron Healthcare, Inc., 2013) has gone furthest, with 21 descendants of its own.
How does its category compare?
All DXN devicesDXN System, Measurement, Blood-Pressure, Non-Invasive: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DXN
28in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DXN
142in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DXN
3in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DXN
239in 2025
MAUDE reports naming product code DXN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 27 | 118 | 0 | 21 |
| 2008 | 23 | 82 | 1 | 8 |
| 2009 | 46 | 73 | 3 | 17 |
| 2010 | 43 | 94 | 0 | 14 |
| 2011 | 34 | 72 | 1 | 10 |
| 2012 | 36 | 116 | 0 | 19 |
| 2013 | 34 | 150 | 1 | 72 |
| 2014 | 29 | 133 | 0 | 47 |
| 2015 | 30 | 97 | 0 | 62 |
| 2016 | 30 | 144 | 1 | 54 |
| 2017 | 33 | 184 | 0 | 90 |
| 2018 | 22 | 235 | 0 | 617 |
| 2019 | 33 | 156 | 1 | 96 |
| 2020 | 24 | 198 | 0 | 130 |
| 2021 | 23 | 190 | 0 | 162 |
| 2022 | 25 | 137 | 0 | 155 |
| 2023 | 35 | 182 | 0 | 162 |
| 2024 | 17 | 107 | 3 | 270 |
| 2025 | 28 | 142 | 0 | 239 |
| 2026 | 29 | 147 | 0 | — |
What is it indicated for?
The device is a digital monitor intended for use in measuring blood pressure and pulse rate in adult patient population with wrist circumference ranging from 5 1/4 inches to 8 1/2 inches (13.5 cm to 21.5 cm).
The device detects the appearance of irregular heartbeats during measurement and gives a warning signal with readings.
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K042505 · printed Nov 6, 2026
Cite this page
510(k) Report. “K042505: Omron Digital Wrist Blood Pressure Monitor, Model Hem-609N.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K042505
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026