510(k) · Cleared
ClearedExam-Pacs
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Coactiv, LLC · LLZ System, Image Processing, Radiological
Cleared on Oct 7, 2004 as substantially equivalent to K032533 (Intelerad Medical Systems, Inc., 2003) after a 9-day review. Its family tree reaches back 4 generations to 2001.
- Decided
- Oct 7, 2004
- Review
- 9 days
- Class
- Class II
- Product code
- LLZ
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 4 generations to K010259 (2001). No later device cites it as a predicate yet.
- Root · 4 generations backK010259 Mediface PacsMediface Co., Ltd. · 2001
- 3 generations backK012844 Marosis PacsMarotech, Inc. · 2001
- 2 generations backK023460 PacsplusMedical Standard Co., Ltd. · 2003
- 1 generation backK032533 IntelepacsIntelerad Medical Systems, Inc. · 2003
- This deviceK042647 Exam-PacsCoactiv, LLC · 2004
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LLZ device
- #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K032533 | IntelepacsSummary page 1…vice Classification Name System, Image Processing, Radiology Regulation Number 892.2050 510(k) Number K032533 Device Name INTELEPACS TM Applicant Intelerad Medical Systems Inc… | 2003 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 3 years and passes through 5 companies; a new generation was cleared every 12 months on median.
- None of the 4 ancestors has a recall.
- 1 other device also cites its predicate K032533.
How does its category compare?
All LLZ devicesLLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · LLZ
58in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LLZ
173in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LLZ
11in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LLZ
116in 2025
MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 76 | 36 | 20 | 152 |
| 2008 | 94 | 52 | 32 | 154 |
| 2009 | 70 | 62 | 21 | 145 |
| 2010 | 51 | 98 | 17 | 145 |
| 2011 | 106 | 79 | 30 | 454 |
| 2012 | 82 | 87 | 12 | 266 |
| 2013 | 95 | 84 | 64 | 1,130 |
| 2014 | 78 | 89 | 6 | 15,631 |
| 2015 | 64 | 90 | 16 | 211 |
| 2016 | 82 | 90 | 12 | 290 |
| 2017 | 78 | 107 | 5 | 104 |
| 2018 | 104 | 105 | 7 | 72 |
| 2019 | 74 | 107 | 2 | 88 |
| 2020 | 81 | 115 | 6 | 82 |
| 2021 | 83 | 116 | 3 | 70 |
| 2022 | 65 | 137 | 4 | 28 |
| 2023 | 87 | 157 | 8 | 26 |
| 2024 | 62 | 131 | 6 | 42 |
| 2025 | 58 | 173 | 11 | 116 |
| 2026 | 45 | 110 | 14 | — |
What is it indicated for?
Exam-PACSTM is a device that receives digital images (including mammograms) and data from various sources (e.g. CT scanners, MR scanners, ultrasound systems, R/F units, computer & direct radiographic devices, secondary capture devices, scanners, imaging gateways or other imaging sources). Images and data can be communicated, processed, manipulated, enhanced, stored, and displayed within the system and or across computer networks at distributed locations.…
Read the full statement (119 words)
Exam-PACSTM is a device that receives digital images (including mammograms) and data from various sources (e.g. CT scanners, MR scanners, ultrasound systems, R/F units, computer & direct radiographic devices, secondary capture devices, scanners, imaging gateways or other imaging sources). Images and data can be communicated, processed, manipulated, enhanced, stored, and displayed within the system and or across computer networks at distributed locations.
Lossy compressed mammographic images and digitized film screen images must not be reviewed for primary image interpretations. Mammographic images may only be interpreted using an FDA approved monitor that offers at least 5 Mpixel resolution and meets other technical specifications reviewed and accepted by FDA.
Typical users of this system are trained professionals, physicians, nurses, and technicians.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K042647 · printed Nov 4, 2026
Cite this page
510(k) Report. “K042647: Exam-Pacs.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K042647
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026