510(k) Report

510(k) · Cleared

Cleared

Liquichek Reticulocyte Control (a)

K042836510(k) TraditionalCleared Nov 5, 200422-day reviewClass II21 CFR 864.8625

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bio-Rad · JPK Mixture, Hematology Quality Control

Cleared on Nov 5, 2004 as substantially equivalent to K993496 (Hematronix, Inc., 1999) after a 22-day review. Its family tree reaches back 2 generations to 1993.

Decided
Nov 5, 2004
Review
22 days
Class
Class II
Product code
JPK
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K930119 (1993). No later device cites it as a predicate yet.

  1. Root · 2 generations backK930119 Coulter Retic-C Cell ControlCoulter Electronics, Inc. · 1993
  2. 1 generation backK993496 Retic-QuinoxHematronix, Inc. · 1999
  3. This deviceK042836 Liquichek Reticulocyte Control (a)Bio-Rad · 2004
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K930119Coulter Retic-C Cell ControlCoulter Electronics, Inc.1993—
−1K993496Retic-QuinoxHematronix, Inc.1999—
0 (this device)K042836Liquichek Reticulocyte Control (a)Bio-Rad2004—
FIG. 1 — Lineage of K042836, 1993–2004Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JPK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K993496Retic-Quinox
Summary page 1
…Liquichek Reticulocyte Control Bio-Rad Laboratories (formerly known as Hematronix, Inc.) Benicia, California 94510 510 (k) Number: K993496 4.0 DescriptionofDevice This is a liquid product composed of stabilized human red blood…
Hematronix, Inc.1999—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 3 companies; a new generation was cleared every 6.7 years on median.
  • None of the 2 ancestors has a recall.

How does its category compare?

All JPK devices

JPK Mixture, Hematology Quality Control: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JPK

4in 2016

2007: 52009: 52010: 42011: 12012: 22013: 12014: 22016: 4
2007high 5 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JPK

296in 2016

2007: 44 days median2009: 187 days median2010: 267 days median2016: 296 days median
2007high 296 (2016) · low 44 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JPK

1in 2022

2007: 12010: 22011: 32012: 12020: 12021: 22022: 1
2007high 3 (2011) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JPK

2in 2023

2007: 142008: 12010: 52011: 562012: 22014: 12019: 12020: 12021: 12023: 2
2007high 56 (2011) · low 0 (2009)2025

MAUDE reports naming product code JPK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007544114
20080—01
2009518700
2010426725
20111—356
20122—12
20131—00
20142—01
20150—00
2016429600
20170—00
20180—00
20190—01
20200—11
20210—21
20220—10
20230—02
20240—00
20250—00
20260—0—

What is it indicated for?

Liquichek Reticulocyte Control (A) is an assayed whole blood control for evaluating precision of automated methods of reticulocyte counting.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K042836: Liquichek Reticulocyte Control (a).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K042836

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026