510(k) Report

510(k) · Cleared

Cleared

Watch Pat 100S

K042916510(k) TraditionalCleared Dec 29, 200469-day reviewClass II21 CFR 868.2375

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Itamar Medical · MNR Ventilatory Effort Recorder

Cleared on Dec 29, 2004 after a 69-day review. The FDA summary names its predicate without a number. 71 later devices descend from it.

Decided
Dec 29, 2004
Review
69 days
Class
Class II
Product code
MNR
Recalls
None
Predicates
0

71 later devices descend from it, 3 citing it directly.

Descendants, by year cleared 2008: 3 descendants cleared2007: 1 descendant cleared2011: 4 descendants cleared2014: 2 descendants cleared2017: 5 descendants cleared2012: 3 descendants cleared2013: 3 descendants cleared2016: 2 descendants cleared2015: 3 descendants cleared2018: 3 descendants cleared2020: 3 descendants cleared2022: 8 descendants cleared2024: 5 descendants cleared2019: 2 descendants cleared2026: 9 descendants cleared2023: 6 descendants cleared2025: 7 descendants cleared2021: 2 descendants cleared200020052010201520202025
  1. This deviceK042916 Watch Pat 100SItamar Medical · 2004
  2. Descendant · cites it directly · 43 of its ownK071230 Apnea Risk Evaluation System (Ares), Model 600Advanced Brain Monitoring, Inc. · 2007
  3. Descendant · 2 generations on · 41 of its ownK110705 Apnea Risk Evaluation System (Ares)Advanced Brain Monitoring, Inc. · 2011
  4. Descendant · 3 generations on · 40 of its ownK111194 Apnea Risk Evaluation System (Ares)Advanced Brain Monitoring, Inc. · 2011
  5. Descendant · 4 generations on · 38 of its ownK112514 Apnea Risk Evaluation System (Ares)Advanced Brain Monitoring, Inc. · 2012
  6. Descendant · cites it directly · 25 of its ownK081037 Watch-Pat 200I (WP200I)Itamar Medical · 2008

Showing 5 of 71 descendants. See all descendants

Descendants cleared per year

2007: 12008: 32011: 42012: 32013: 32014: 22015: 32016: 22017: 52018: 32019: 22020: 32021: 22022: 82023: 62024: 52025: 72026: 9
2007high 9 (2026) · low 0 (2009)2026

Most influential descendants

Showing 5 of 71 · See all
  • K071230Apnea Risk Evaluation System (Ares), Model 600Advanced Brain Monitoring, Inc. · 2007 · cites it directly43descendants
  • K110705Apnea Risk Evaluation System (Ares)Advanced Brain Monitoring, Inc. · 2011 · 2 generations on41descendants
  • K111194Apnea Risk Evaluation System (Ares)Advanced Brain Monitoring, Inc. · 2011 · 3 generations on40descendants
  • K112514Apnea Risk Evaluation System (Ares)Advanced Brain Monitoring, Inc. · 2012 · 4 generations on38descendants
  • K081037Watch-Pat 200I (WP200I)Itamar Medical · 2008 · cites it directly25descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K042916Watch Pat 100SItamar Medical2004—
+1K071230Apnea Risk Evaluation System (Ares), Model 600Advanced Brain Monitoring, Inc.2007—
+2K110705Apnea Risk Evaluation System (Ares)Advanced Brain Monitoring, Inc.2011—
+3K111194Apnea Risk Evaluation System (Ares)Advanced Brain Monitoring, Inc.2011—
+4K112514Apnea Risk Evaluation System (Ares)Advanced Brain Monitoring, Inc.2012—
+1K081037Watch-Pat 200I (WP200I)Itamar Medical2008—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200710
200830
201140
201230
201330
201420
201530
201620
201750
201830
201920
202030
202120
202280
202360
202450
202570
202690
FIG. 1 — Lineage of K042916, 2004–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MNR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MNR device

  1. #1 K244027 Sansa Hsatscore 18.1 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Itamar's Watch PAT 100 (WP100)
Named without a submission number
—
*—Oxford BioSignal's BioSleep (BioSleep)
Named without a submission number
—

What descends from it? (71)

See all 71

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K071230Apnea Risk Evaluation System (Ares), Model 600Advanced Brain Monitoring, Inc.200743
K081037Watch-Pat 200I (WP200I)Itamar Medical200825
K080427Watch-Pat Model 100S-2Itamar Medical200825

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K071230 (Advanced Brain Monitoring, Inc., 2007) has gone furthest, with 43 descendants of its own.

How does its category compare?

All MNR devices

MNR Ventilatory Effort Recorder: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MNR

10in 2025

2007: 62008: 142009: 82011: 92012: 12013: 42014: 22015: 42016: 32017: 42018: 32019: 82020: 52021: 32022: 72023: 62024: 62025: 102026 (partial year): 5
2007high 14 (2008) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MNR

165in 2025

2007: 124 days median2008: 118 days median2009: 89 days median2011: 90 days median2013: 161 days median2015: 229 days median2016: 281 days median2017: 275 days median2018: 147 days median2019: 383 days median2020: 192 days median2021: 137 days median2022: 266 days median2023: 183 days median2024: 217 days median2025: 165 days median2026 (partial year): 227 days median
2007high 383 (2019) · low 89 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MNR

1in 2021

2007: 22009: 12011: 12021: 12026 (partial year): 1
2007high 2 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MNR

43in 2025

2007: 12010: 12011: 12012: 12014: 12015: 42016: 102017: 42018: 22019: 32020: 52021: 52022: 42023: 132024: 112025: 43
2007high 43 (2025) · low 0 (2008)2025

MAUDE reports naming product code MNR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007612421
20081411800
200988910
20100—01
201199011
20121—01
2013416100
20142—01
2015422904
20163281010
2017427504
2018314702
2019838303
2020519205
2021313715
2022726604
20236183013
20246217011
202510165043
202652271—

What is it indicated for?

The Watch-PAT 100S ("WP100S") device is a non-invasive home care device for use with patients suspected to have sleep related breathing disorders. The WP100S is a diagnostic aid for the detection of sleep related breathing disorders and rapid eye movement ("REM") sleep stages. The WP100S generates a peripheral arterial tonometry ("PAT") respiratory disturbance index ("PRDI") and PAT REM sleep stage identification ("PREM"). The WP100S's PREM provides…

Read the full statement (124 words)

The Watch-PAT 100S ("WP100S") device is a non-invasive home care device for use with patients suspected to have sleep related breathing disorders. The WP100S is a diagnostic aid for the detection of sleep related breathing disorders and rapid eye movement ("REM") sleep stages. The WP100S generates a peripheral arterial tonometry ("PAT") respiratory disturbance index ("PRDI") and PAT REM sleep stage identification ("PREM"). The WP100S's PREM provides supplemental information to its PRDI. The WP100S's PREM is not intended to be used as the sole or primary basis for diagnosing any sleep related breathing disorder, prescribing treatment, or determining whether additional diagnostic assessment is warranted.

The WP100S is not indicated for children less than 17 years old. The WP100S is contraindicated for patients with latex allergy.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K042916: Watch Pat 100S.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K042916

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026