K043044510(k) TraditionalCleared May 6, 2005183-day reviewClass II21 CFR 876.5980Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Viasys Medsystems · KNT Tubes, Gastrointestinal (And Accessories)

Cleared on May 6, 2005 after a 183-day review. FDA’s file for it is a 510(k) statement, which names no predicate. It has been recalled 2 times.

Decided
May 6, 2005
Review
183 days
Class
Class II
Product code
KNT
Recalls
2
Predicates
0

FDA’s file for it is a 510(k) statement, which names no predicate.

FIG. 1 — Lineage of K043044Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KNT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KNT device

  1. #1 K261890 52Fr ViSiGi LUX™; 52Fr ViSiGi 3D®score 12.7 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Oct 16, 2020Class IIZ-0540-2021Under Investigation by firmDetachment of the Male AIV Adaptor from the Y-Connector.
Jun 25, 2008Not classifiedZ-2306-2008Mixed-up of materials/componentsThe male Luer adapter may be the wrong component therefore the feeding set would not be able to be connected to the tube nor would the cap fit securely.

No ancestor or descendant has a Class I recall.

How does its category compare?

All KNT devices

KNT Tubes, Gastrointestinal (And Accessories): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KNT

4in 2025

2007: 102008: 102009: 112010: 122011: 72012: 122013: 72014: 162015: 102016: 62017: 92018: 72019: 102020: 52021: 62022: 72023: 52024: 92025: 42026 (partial year): 3
2007high 16 (2014) · low 4 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KNT

136in 2025

2007: 118 days median2008: 115 days median2009: 102 days median2010: 104 days median2011: 211 days median2012: 107 days median2013: 128 days median2014: 259 days median2015: 140 days median2016: 99 days median2017: 247 days median2018: 149 days median2019: 126 days median2020: 102 days median2021: 121 days median2022: 110 days median2023: 162 days median2024: 103 days median2025: 136 days median2026 (partial year): 105 days median
2007high 259 (2014) · low 99 (2016)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KNT

13in 2025

2007: 12008: 822009: 92010: 32011: 22012: 12015: 12016: 32017: 42018: 22019: 22020: 12021: 22022: 1, 1 Class I2023: 22025: 132026 (partial year): 20
2007high 82 (2008) · low 0 (2013)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · KNT

1,451in 2025

2007: 3002008: 8672009: 8182010: 5172011: 5312012: 5282013: 7472014: 1,0302015: 1,0482016: 1,2512017: 1,6722018: 1,9012019: 1,8382020: 1,6412021: 1,6552022: 1,6502023: 1,8632024: 1,3442025: 1,451
2007high 1,901 (2018) · low 300 (2007)2025

MAUDE reports naming product code KNT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007101181300
20081011582867
2009111029818
2010121043517
201172112531
2012121071528
201371280747
20141625901,030
20151014011,048
201669931,251
2017924741,672
2018714921,901
20191012621,838
2020510211,641
2021612121,655
202271101 (1)1,650
2023516221,863
2024910301,344
20254136131,451
2026310520—

What is it indicated for?

The Anti-I.V. Enteral Feeding System is intended for use in those patients who require intermittent or continuous tube feedings via the nasogastric or nasoentric route. The Anti-I.V. Enteral Feeding Tube is intended for use in those patients who require intermittent or continuous tube feedings via the nasogastric or nasoentric route. The Anti-I.V. Enteral Feeding Extension Set is intended to be used to deliver enteral formula from the nutritional source to the Anti-IN. Enteral Feeding Tube. The Anti-I.V. Enteral Feeding System is for pediatric and neonatal use only.

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K043044: Anti-I.V. Enteral Feeding System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K043044

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026