510(k) Report

510(k) · Cleared

Cleared

Fisch Titanium Middle Ear Prostheses

K043375510(k) TraditionalCleared Jan 24, 200547-day reviewClass II21 CFR 874.3495

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Karl Storz Endoscopy · ETA Replacement, Ossicular Prosthesis, Total

Cleared on Jan 24, 2005 as substantially equivalent to K993583 (Stryker Corp., 1999) after a 47-day review. Its family tree reaches back 1 generation to 1999.

Decided
Jan 24, 2005
Review
47 days
Class
Class II
Product code
ETA
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K993583 (1999). No later device cites it as a predicate yet.

K993583 · Zurich Titanium Ossicular Replacement System · Stryker Corp. · 1999199619982000200220042006
  1. Root · 1 generation backK993583 Zurich Titanium Ossicular Replacement SystemStryker Corp. · 1999
  2. This deviceK043375 Fisch Titanium Middle Ear ProsthesesKarl Storz Endoscopy · 2005
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K993583Zurich Titanium Ossicular Replacement SystemStryker Corp.1999—
0 (this device)K043375Fisch Titanium Middle Ear ProsthesesKarl Storz Endoscopy2005—
FIG. 1 — Lineage of K043375, 1999–2005Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ETA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ETA device

  1. #1 K241269 mXACT Total Prosthesis Offcenter, mXACT Total…score 12.0 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K993583Zurich Titanium Ossicular Replacement System
Summary page 2
…ium Stapes Prosthesis DEVICE STRYKER/ LEIBINGER - FISCH KARL STORZ - FISCH TITANIUM TITANIUM STAPES PISTON (K993583) STAPES PISTON 1.INTENDED USE Flat band and piston prosthesis for Same…
Stryker Corp.1999—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.

How does its category compare?

All ETA devices

ETA Replacement, Ossicular Prosthesis, Total: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · ETA

1in 2025

2009: 22025: 12026 (partial year): 2
2007high 2 (2009) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ETA

Too few ETA 510(k)s in any year since 2007 to give a median.

Recalls per year · ETA

1in 2011

2011: 1
2007high 1 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · ETA

4in 2025

2008: 52009: 22010: 12011: 32012: 42013: 12014: 62015: 52016: 122017: 92019: 92020: 12022: 42023: 52024: 82025: 4
2007high 12 (2016) · low 0 (2007)2025

MAUDE reports naming product code ETA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—05
20092—02
20100—01
20110—13
20120—04
20130—01
20140—06
20150—05
20160—012
20170—09
20180—00
20190—09
20200—01
20210—00
20220—04
20230—05
20240—08
20251—04
20262—0—

What is it indicated for?

The FISCH Titanium Middle Ear Prostheses are intended for ossicle replacement to restore middle ear function when the sound transmission chain is broken. The various prosthetic models are implanted for partial or complete reconstruction, to replace missing or malformed ossicles or in secondary procedures after tumor or trauma operations.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K043375: Fisch Titanium Middle Ear Prostheses.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K043375

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026