510(k) · Cleared
Recalled · 2008Sterilmed Reprocessed Deflectable Electrophysiology Diagnostic Catheter
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Sterilmed, Inc. · NLH Catheter, Recording, Electrode, Reprocessed
Cleared on Mar 1, 2005 as substantially equivalent to K953768 (Cordis Webster, Inc., 1995) after a 71-day review. Its family tree reaches back 1 generation to 1995. It has been recalled once.
- Decided
- Mar 1, 2005
- Review
- 71 days
- Class
- Class II
- Product code
- NLH
- Recalls
- 1
- Predicates
- 2
Its longest line of descent runs back 1 generation to K953768 (1995). No later device cites it as a predicate yet.
- Root · 1 generation backK953768 Cordis Webster A20 Diagnostic Deflectable Tip CatheterCordis Webster, Inc. · 1995 · Recalled
- This deviceK043513 Sterilmed Reprocessed Deflectable Electrophysiology Diagnostic…Sterilmed, Inc. · 2005
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K953768 | Cordis Webster A20 Diagnostic Deflectable Tip Catheter | Cordis Webster, Inc. | 1995 | 4 |
| 0 (this device) | K043513 | Sterilmed Reprocessed Deflectable Electrophysiology Diagnostic Catheter | Sterilmed, Inc. | 2005 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in NLH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new NLH device
- #1 K252405 Medline ReNewal Reprocessed Boston Scientific…score 10.4 · 1 generation · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K953768 | Cordis Webster A20 Diagnostic Deflectable Tip CatheterSummary page 1…lMed reprocessed deflectable electrophysiology diagnostic catheter is substantially equivalent to: the A20 (K953768), manufactured by Biosense Webster (formerly known as Cordis Webster); the Bard Dynamic Tip Cathet… | 1995 |
| Kept off the family tree | K912213 | Bard Dynamic Tip Catheter Not in FDA’s 510(k), De Novo or PMA lists as we hold them (a misreading, a typo, or a number FDA does not list), so it is kept off the family tree Summary page 1…53768), manufactured by Biosense Webster (formerly known as Cordis Webster); the Bard Dynamic Tip Catheter (K912213), manufactured by C.R. Bard Inc.; and their counterparts from the original manufacturers. Device… |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Aug 8, 2008 | Not classified | Z-0555-2009 | Packaging process control | SteriMed, Inc is conducting a product removal of a small group of devices individually packaged and sealed within a pouch. The removal is being conducted because the possibility exists that some of the pouches were not properly sealed on… |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Its one ancestor has a recall.
- 6 other devices also cite its predicate K953768.
How does its category compare?
All NLH devicesNLH Catheter, Recording, Electrode, Reprocessed: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · NLH
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · NLH
165in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · NLH
28so far in 2026, the most since 2007
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · NLH
66in 2025
MAUDE reports naming product code NLH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 1 |
| 2008 | 2 | — | 1 | 0 |
| 2009 | 1 | — | 0 | 1 |
| 2010 | 3 | 120 | 0 | 8 |
| 2011 | 2 | — | 0 | 10 |
| 2012 | 1 | — | 0 | 9 |
| 2013 | 0 | — | 1 | 6 |
| 2014 | 0 | — | 0 | 17 |
| 2015 | 1 | — | 0 | 34 |
| 2016 | 11 | 133 | 3 | 25 |
| 2017 | 4 | 138 | 0 | 11 |
| 2018 | 4 | 122 | 4 | 21 |
| 2019 | 4 | 195 | 0 | 38 |
| 2020 | 2 | — | 0 | 28 |
| 2021 | 2 | — | 0 | 55 |
| 2022 | 1 | — | 0 | 12 |
| 2023 | 1 | — | 0 | 30 |
| 2024 | 6 | 165 | 0 | 47 |
| 2025 | 2 | — | 0 | 66 |
| 2026 | 0 | — | 28 (1) | — |
What is it indicated for?
The SterilMed Reprocessed Electrophysiological Diagnostic Catheters are intended for temporary use during electrophysiology studies for intracardiac sensing, recording, and stimulation. They also provide temporary pacing for the evaluation of cardiac arrhythmias, and are used for electrophysiology mapping of cardiac structures during these evaluations.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K043513 · printed Nov 4, 2026
Cite this page
510(k) Report. “K043513: Sterilmed Reprocessed Deflectable Electrophysiology Diagnostic Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K043513
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026