510(k) · Cleared
ClearedGeneros, Models GO-01G, GO-05G, GO-10G, GO-15G, GO-20G, GO-30G, GO-40G, GO-60G, GO-Xyz Series, GO-DZ Series
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Berkeley Advanced Biomaterials, Inc. · MQV Filler, Bone Void, Calcium Compound
Cleared on Apr 11, 2005 as substantially equivalent to K023703 (Berkeley Advanced Biomaterials, Inc., 2003) and 1 other predicate after a 28-day review. Its family tree reaches back 1 generation to 2000.
- Decided
- Apr 11, 2005
- Review
- 28 days
- Class
- Class II
- Product code
- MQV
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 1 generation to K994337 (2000). 2 ancestors in all. No later device cites it as a predicate yet.
- Root · 1 generation backK994337 Vitoss Scaffold Synthetic Cancellous Bone Void FillerOrthovita Co. · 2000
- This deviceK050666 Generos, Models GO-01G, GO-05G, GO-10G, GO-15G, GO-20G, GO-30G…Berkeley Advanced Biomaterials, Inc. · 2005
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K994337 | Vitoss Scaffold Synthetic Cancellous Bone Void Filler | Orthovita Co. | 2000 | — |
| 0 (this device) | K050666 | Generos, Models GO-01G, GO-05G, GO-10G, GO-15G, GO-20G, GO-30G, GO-40G… | Berkeley Advanced Biomaterials, Inc. | 2005 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2003 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MQV? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MQV device
- #1 K232315 Catalyst Bone Void Fillerscore 25.2 · 25 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K023703 | BI-OsteticSummary page 1…ant is bioresorbable and radio-opaque. C. SUBSTANTIAL EQUIVALENCE INFORMATION GenerOSTM is substantially equivalent to legally marketed, predicate devices Bi-Ostetic (K023703) and Vitoss (K994337). The products have identical indlications-for-use, identical or very similar composition, and equivalent c… | 2003 |
| * | K994337 | Vitoss Scaffold Synthetic Cancellous Bone Void FillerSummary page 1…and radio-opaque. C. SUBSTANTIAL EQUIVALENCE INFORMATION GenerOSTM is substantially equivalent to legally marketed, predicate devices Bi-Ostetic (K023703) and Vitoss (K994337). The products have identical indlications-for-use, identical or very similar composition, and equivalent contraindications. The… | 2000 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- None of the 2 ancestors has a recall.
- 3 other devices also cite its predicate K023703.
How does its category compare?
All MQV devicesMQV Filler, Bone Void, Calcium Compound: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MQV
14in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MQV
57in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MQV
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MQV
57in 2025
MAUDE reports naming product code MQV, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 35 | 144 | 5 | 67 |
| 2008 | 32 | 102 | 3 | 71 |
| 2009 | 23 | 180 | 1 | 81 |
| 2010 | 17 | 147 | 0 | 68 |
| 2011 | 16 | 92 | 6 | 114 |
| 2012 | 9 | 107 | 3 | 149 |
| 2013 | 12 | 197 | 2 | 223 |
| 2014 | 20 | 153 | 0 | 111 |
| 2015 | 18 | 184 | 0 | 125 |
| 2016 | 8 | 214 | 1 | 106 |
| 2017 | 17 | 124 | 1 | 107 |
| 2018 | 23 | 124 | 2 | 86 |
| 2019 | 13 | 90 | 0 | 65 |
| 2020 | 15 | 132 | 1 | 126 |
| 2021 | 8 | 88 | 0 | 101 |
| 2022 | 9 | 118 | 0 | 47 |
| 2023 | 21 | 74 | 3 | 120 |
| 2024 | 28 | 55 | 2 | 68 |
| 2025 | 14 | 57 | 1 | 57 |
| 2026 | 5 | 96 | 4 | — |
What is it indicated for?
GenerOsTM is an osteoconductive bone substitute shaped as granules or blocks (cancellous, cortical or cortico-cancellous) that are intended to be used to fill voids and gaps that are not intrinsic to the stability of the bone structure. These gaps or voids may be located in the extremities, spine, pelvis, or cranium. The granules or blocks may be pressed into the void or into the surgical site by hand. The GenerOsTM granules or blocks provide void…
Read the full statement (115 words)
GenerOsTM is an osteoconductive bone substitute shaped as granules or blocks (cancellous, cortical or cortico-cancellous) that are intended to be used to fill voids and gaps that are not intrinsic to the stability of the bone structure. These gaps or voids may be located in the extremities, spine, pelvis, or cranium.
The granules or blocks may be pressed into the void or into the surgical site by hand. The GenerOsTM granules or blocks provide void filling material that acts as a temporary support medium. The granules or blocks are not intended to provide structural support during the healing process. The implant is radio-opaque. GenerOsTM is biocompatible and resorbs in the body as bone ingrowth occurs.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K050666 · printed Nov 3, 2026
Cite this page
510(k) Report. “K050666: Generos, Models GO-01G, GO-05G, GO-10G, GO-15G, GO-20G, GO-30G, GO-40G, GO-60G, GO-Xyz Series, GO-DZ Series.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K050666
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026