510(k) Report

510(k) · Cleared

Recalled · 2006

Agfa CR50.0

K050810510(k) SpecialCleared Apr 21, 200521-day reviewClass II21 CFR 892.1680Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Agfa Corp. · MQB Solid State X-Ray Imager (Flat Panel/Digital Imager)

Cleared on Apr 21, 2005 as substantially equivalent to K041701 (Agfa Corp., 2004) after a 21-day review. Its family tree reaches back 4 generations to 1991. It has been recalled 2 times.

Decided
Apr 21, 2005
Review
21 days
Class
Class II
Product code
MQB
Recalls
2
Predicates
1

Its longest line of descent runs back 4 generations to K904519 (1991). No later device cites it as a predicate yet.

  1. Root · 4 generations backK904519 Agfa Diagnostic Center (Adc)Enhanced Imaging Technologies, Inc. · 1991
  2. 3 generations backK974597 Adc Compact (Agfa Diagnostic Center)Bayer Corp., Agfa Div. · 1998 · Recalled
  3. 2 generations backK013138 Adc Compact PlusAgfa-Gevaert AG · 2001
  4. 1 generation backK041701 Afga CR25.0 Computed Radiography SystemAgfa Corp. · 2004
  5. This deviceK050810 Agfa CR50.0Agfa Corp. · 2005
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K904519Agfa Diagnostic Center (Adc)Enhanced Imaging Technologies, Inc.1991—
−3K974597Adc Compact (Agfa Diagnostic Center)Bayer Corp., Agfa Div.19981
−2K013138Adc Compact PlusAgfa-Gevaert AG2001—
−1K041701Afga CR25.0 Computed Radiography SystemAgfa Corp.2004—
0 (this device)K050810Agfa CR50.0Agfa Corp.2005—
FIG. 1 — Lineage of K050810, 1991–2005Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQB device

  1. #1 K201528 Yushan X-Ray Flat Panel Detector with DROCscore 21.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K041701Afga CR25.0 Computed Radiography System
Summary page 1
…10(k) for Device Modification. The predicate device is the device that was modifted to produce the CR50.0, namely the CR25.0, which was cleared by FDA on 22 July 2004 as K041701. B. DEVICE DESCRIPTION The CR50.0, the predicate device, is a computed radiology imaging system. Instead of screens and photogr…
Agfa Corp.2004—

Also cleared against K041701: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 28, 2006Not classifiedZ-0031-2007OtherThree separate issues involving the Agfa DX-S CR System, were detected that could lead to an image loss.
Nov 3, 2005Not classifiedZ-0855-06OtherCorrupted image after system start; Corrupted image after workflow interruption; An erasure unit problem can cause system to stop.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 4 companies; a new generation was cleared every 3.6 years on median.
  • 1 of the 4 ancestors has a recall of any class.
  • 2 other devices also cite its predicate K041701.

How does its category compare?

All MQB devices

MQB Solid State X-Ray Imager (Flat Panel/Digital Imager): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MQB

8in 2025

2007: 132008: 82009: 152010: 112011: 242012: 222013: 212014: 322015: 212016: 222017: 312018: 162019: 222020: 192021: 212022: 312023: 102024: 82025: 82026 (partial year): 3
2007high 32 (2014) · low 8 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQB

127in 2025

2007: 22 days median2008: 15 days median2009: 57 days median2010: 116 days median2011: 102 days median2012: 80 days median2013: 105 days median2014: 102 days median2015: 81 days median2016: 92 days median2017: 30 days median2018: 30 days median2019: 30 days median2020: 28 days median2021: 48 days median2022: 48 days median2023: 30 days median2024: 187 days median2025: 127 days median2026 (partial year): 245 days median
2007high 245 (2026) · low 15 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQB

1in 2025

2007: 152008: 362009: 192010: 142011: 102012: 82013: 62017: 12018: 42019: 12020: 42021: 12025: 12026 (partial year): 1
2007high 36 (2008) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQB

141in 2025

2007: 252008: 302009: 342010: 392011: 1012012: 2672013: 1592014: 292015: 212016: 262017: 202018: 842019: 452020: 92021: 262022: 132023: 512024: 912025: 141
2007high 267 (2012) · low 9 (2020)2025

MAUDE reports naming product code MQB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200713221525
20088153630
200915571934
2010111161439
20112410210101
201222808267
2013211056159
201432102029
20152181021
20162292026
20173130120
20181630484
20192230145
2020192849
20212148126
20223148013
20231030051
20248187091
202581271141
202632451—

What is it indicated for?

The CR50.0 is indicated for use to provide diagnostic quality images to aid in physician diagnosis. The CR50.0 is intended to be used mainly in chest, skeletal and gastro-intestinal imaging applications.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K050810: Agfa CR50.0.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K050810

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026