510(k) · Cleared
Recalled · Class II · 2026Claviculaplate with Angular Stablity Bone Plate System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
I.T.S. Implantat-Technologie-Systeme GmbH · HRS Plate, Fixation, Bone
Cleared on Jun 22, 2005 as substantially equivalent to K011334 (Synthes (Usa), 2001) and 1 other predicate after a 79-day review. Its family tree reaches back 3 generations to 2000. 38 later devices descend from it. It has been recalled once.
- Decided
- Jun 22, 2005
- Review
- 79 days
- Class
- Class II
- Product code
- HRS
- Recalls
- 1
- Predicates
- 3
Its longest line of descent runs back 3 generations to K000684 (2000). 8 ancestors in all, the oldest K890939 (1989). 38 later devices descend from it, 4 citing it directly.
- Root · 3 generations backK000684 Small Fragment Dynamic Compression Locking (DCL) SystemSynthes (Usa) · 2000 · Recalled
- 2 generations backK011335 Synths One-Third Tubular DCL PlateSynthes (Usa) · 2001 · Recalled
- 1 generation backK012655 Congruent Bone Plate SystemAcu Med, Inc. · 2001 · Recalled
- This deviceK050852 Claviculaplate with Angular Stablity Bone Plate SystemI.T.S. Implantat-Technologie-Systeme GmbH · 2005
- Descendant · cites it directly · 27 of its ownK060156 Straight Plate with Angular Stability & Screw SystemI.T.S. Implantat-Technologie-Systeme GmbH · 2006 · Recalled
- Descendant · 2 generations on · 9 of its ownK150693 PHIN-FX Cannulated Lag Screw SystemAscent Medical, LLC · 2015
- Descendant · cites it directly · 9 of its ownK100944 Clavicle Locking Plate SystemNewclip Technics · 2010
- Descendant · 2 generations on · 9 of its ownK063166 I.T.S. Pelvic Reconstruction SystemI.T.S. Implantat-Technologie-Systeme GmbH · 2006 · Recalled
- Descendant · 2 generations on · 8 of its ownK110895 Ortho Solutions Trauma Implants for OsteosynthesisOrtho Solutions Limited · 2011
Showing 5 of 38 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 38 · See all- K060156Straight Plate with Angular Stability & Screw SystemI.T.S. Implantat-Technologie-Systeme GmbH · 2006 · cites it directly27descendants
- K150693PHIN-FX Cannulated Lag Screw SystemAscent Medical, LLC · 2015 · 2 generations on9descendants
- K100944Clavicle Locking Plate SystemNewclip Technics · 2010 · cites it directly9descendants
- K063166I.T.S. Pelvic Reconstruction SystemI.T.S. Implantat-Technologie-Systeme GmbH · 2006 · 2 generations on9descendants
- K110895Ortho Solutions Trauma Implants for OsteosynthesisOrtho Solutions Limited · 2011 · 2 generations on8descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K000684 | Small Fragment Dynamic Compression Locking (DCL) System | Synthes (Usa) | 2000 | 1 |
| −2 | K011335 | Synths One-Third Tubular DCL Plate | Synthes (Usa) | 2001 | 2 |
| −1 | K012655 | Congruent Bone Plate System | Acu Med, Inc. | 2001 | 16 |
| 0 (this device) | K050852 | Claviculaplate with Angular Stablity Bone Plate System | I.T.S. Implantat-Technologie-Systeme GmbH | 2005 | — |
| +1 | K060156 | Straight Plate with Angular Stability & Screw System | I.T.S. Implantat-Technologie-Systeme GmbH | 2006 | 2 |
| +2 | K150693 | PHIN-FX Cannulated Lag Screw System | Ascent Medical, LLC | 2015 | — |
| +1 | K100944 | Clavicle Locking Plate System | Newclip Technics | 2010 | — |
| +2 | K063166 | I.T.S. Pelvic Reconstruction System | I.T.S. Implantat-Technologie-Systeme GmbH | 2006 | 2 |
| +2 | K110895 | Ortho Solutions Trauma Implants for Osteosynthesis | Ortho Solutions Limited | 2011 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1989 | 1 | 0 |
| 1991 | 1 | 0 |
| 1995 | 1 | 0 |
| 2000 | 1 | 0 |
| 2001 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2006 | 2 | 0 |
| 2010 | 2 | 0 |
| 2011 | 2 | 0 |
| 2012 | 1 | 0 |
| 2013 | 2 | 0 |
| 2014 | 1 | 0 |
| 2015 | 3 | 0 |
| 2016 | 1 | 0 |
| 2017 | 5 | 0 |
| 2020 | 2 | 0 |
| 2021 | 2 | 0 |
| 2022 | 4 | 0 |
| 2023 | 3 | 0 |
| 2024 | 1 | 0 |
| 2025 | 1 | 0 |
| 2026 | 6 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HRS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HRS device
- #1 K222465 Tyber Medical Anatomical Plating Systemscore 27.5 · 16 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K011334 | Synthes Curved Reconstruction Plate | 2001 |
| Kept off the family tree | K010335 | FDA’s K010335 is Slendertone Flex, Model, 512 Not matched in our reading of the summary (scans can blur digits), so it is kept off the family tree | 2001 |
| * | K012655 | Congruent Bone Plate SystemSummary page 1…Curved Reconstruction Plate (KOI 1334) EQUIVALENT DEVICES Synthes One -Third Tubular DCL Plate (K1011335) Acumed Clavicle/Congruent Plate (K012655) Synthes Hook Plate DEVICE DESCRIPTION: The I.T.S. Claviculaplate with Angular Stability is a low-… | 2001 |
| * | — | Synthes Hook Plate Named without a submission number |
What descends from it? (38)
See all 384 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Jan 23, 2026 | Class II | Z-1593-2026 | No Marketing Application | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 5 years and passes through 3 companies; a new generation was cleared every 1.2 years on median.
- 4 of the 8 ancestors have a recall of any class.
- Of its descendants, K060156 (I.T.S. Implantat-Technologie-Systeme GmbH, 2006) has gone furthest, with 27 descendants of its own.
- 4 other devices also cite its predicate K011334.
How does its category compare?
All HRS devicesHRS Plate, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · HRS
54in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HRS
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HRS
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HRS
2,306in 2025
MAUDE reports naming product code HRS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 35 | 63 | 2 | 339 |
| 2008 | 35 | 87 | 11 | 311 |
| 2009 | 47 | 85 | 3 | 435 |
| 2010 | 49 | 100 | 16 | 491 |
| 2011 | 43 | 88 | 5 | 773 |
| 2012 | 59 | 106 | 4 | 1,663 |
| 2013 | 56 | 89 | 11 | 2,643 |
| 2014 | 76 | 57 | 0 | 2,413 |
| 2015 | 56 | 97 | 7 | 3,095 |
| 2016 | 44 | 109 | 5 | 2,276 |
| 2017 | 57 | 122 | 3 | 2,220 |
| 2018 | 40 | 116 | 2 | 2,663 |
| 2019 | 46 | 89 | 25 | 3,359 |
| 2020 | 48 | 88 | 1 | 2,790 |
| 2021 | 40 | 87 | 9 | 2,442 |
| 2022 | 47 | 144 | 3 | 1,700 |
| 2023 | 40 | 120 | 1 | 2,049 |
| 2024 | 54 | 96 | 0 | 1,849 |
| 2025 | 54 | 90 | 1 | 2,306 |
| 2026 | 51 | 82 | 3 | — |
What is it indicated for?
The I.T.S. Claviculatplate with Angular Stability is a titanium implant
fracture fixation system for repairing fractures located from the middle
third to the distal third of the clavicle.
Indications for Use include metaphysial and diaphysial fracture fixation of
acute fractures, malunions, and non-unions of the clavicle. Other
indications include corrective osteotomy and open and closed fractures.
The system is not intended for spinal use.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K050852 · printed Nov 6, 2026
Cite this page
510(k) Report. “K050852: Claviculaplate with Angular Stablity Bone Plate System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K050852
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026